QDTB® Transformer

Product Search

Find the right transformer for your needs

GCS-12(Z) Series High Voltage Switchgear

15 Models available

GCS-12(Z) High Voltage Switchgear

Images are for illustration purposes only

GCS Series - Medium-Position Withdrawable HV Switchgear

The GCS series medium-position withdrawable switchgear features compact design for restricted space installations. Equipped with VCB and drawout carriage mechanism, provides reliable medium voltage switching with efficient space utilization.

Model Number Breakdown

GSwitchgear (Kaiguan)
CWithdrawable (Chouchu)
SMedium-position (Zhongzhi)

Applications

1

Space-constrained switchrooms

2

Urban indoor substations

3

Commercial building MV distribution

4

Industrial facility power systems

Key Features

  • Medium-position withdrawable design
  • Compact layout for restricted spaces
  • VCB with drawout carriage mechanism
  • Multiple breaking capacity options (25kA to 40kA)

Specifications Range

All specifications and dimensions can be customized upon request

Key parametersModel Range
Rated Voltage12
Rated Current630 A
Breaking Current25–40 kA
Short-time Withstand Current25–40 kA
Protection LevelIP4X
Mechanical Life10000 ops
Operating MechanismSpring-operated (integrated VCB)
StandardGB3906, IEC 62271-200
Select 2-3 models to compare
CompareModelSeriesRated voltage (kV)Current (A)Frequency (Hz)StandardWeightDimensions
GCS-12(Z)/630-25GCS-12(Z)1263050GB3906, IEC 62271-200700 kg900×1500×2300 mm
GCS-12(Z)/630-31.5GCS-12(Z)1263050GB3906, IEC 62271-200700 kg900×1500×2300 mm
GCS-12(Z)/630-40GCS-12(Z)1263050GB3906, IEC 62271-200700 kg900×1500×2300 mm
GCS-12(Z)/1250-25GCS-12(Z)1263050GB3906, IEC 62271-200700 kg900×1500×2300 mm
GCS-12(Z)/1250-31.5GCS-12(Z)1263050GB3906, IEC 62271-200700 kg900×1500×2300 mm
GCS-12(Z)/1250-40GCS-12(Z)1263050GB3906, IEC 62271-200700 kg900×1500×2300 mm
GCS-12(Z)/2000-25GCS-12(Z)1263050GB3906, IEC 62271-200700 kg900×1500×2300 mm
GCS-12(Z)/2000-31.5GCS-12(Z)1263050GB3906, IEC 62271-200700 kg900×1500×2300 mm
GCS-12(Z)/2000-40GCS-12(Z)1263050GB3906, IEC 62271-200700 kg900×1500×2300 mm
GCS-12(Z)/2500-25GCS-12(Z)1263050GB3906, IEC 62271-200700 kg900×1500×2300 mm
GCS-12(Z)/2500-31.5GCS-12(Z)1263050GB3906, IEC 62271-200700 kg900×1500×2300 mm
GCS-12(Z)/2500-40GCS-12(Z)1263050GB3906, IEC 62271-200700 kg900×1500×2300 mm
GCS-12(Z)/3150-25GCS-12(Z)1263050GB3906, IEC 62271-200700 kg900×1500×2300 mm
GCS-12(Z)/3150-31.5GCS-12(Z)1263050GB3906, IEC 62271-200700 kg900×1500×2300 mm
GCS-12(Z)/3150-40GCS-12(Z)1263050GB3906, IEC 62271-200700 kg900×1500×2300 mm

Product Drawing

High Voltage Switchgear - GCS-12(Z)/630-25

APPEARANCE — METAL-CLAD CABINET
HV SWITCHGEAR — FRONT VIEWpressure reliefrelay / meter panelbreaker view windowcable compartmentGCS-12(Z)/630-25
STRUCTURE — THREE COMPARTMENTS
BUSBAR ROOMBREAKER TRUCKwithdrawableCABLE ROOMGCS-12(Z)/630-25
MAIN CIRCUIT — SINGLE-LINE
HV SWITCHGEAR — MAIN CIRCUITBUSCTgroundPTCABLE OUTGCS-12(Z)/630-25
SWITCHGEAR LINE-UP
SWITCHGEAR LINE-UP (INCOMING + FEEDERS)INF1F2F3common busbarGCS-12(Z)/630-25

Note: This is a general product illustration. For detailed technical drawings and specifications, please contact our engineering team.

Instant Selection & Quote Calculator

Select your specifications to get an estimated price instantly.

1 · Configure
More options(5)
Certification
2 · Your price
Derived Ratings (calculated from the configuration)

The values below are computed from what you selected above. Anything that cannot be computed yet is shown as an em dash — never as zero.

Iₙ = S / (√3·U) · I_sc = 100·Iₙ / uₖ · S_sc = √3·U·I_sc · I_p = k·Iₖ

Inputs taken from the configuration
System voltage: not specified
Short-time withstand current: not specified
Peak withstand current: not specified
Switchgear system basis: HV switchgear — IEC 62271-1
Frequency: —
Result
Short-time withstand current Iₖ / I_cw—
Peak withstand current I_p / I_pk—
Peak factor k—
System voltage → —

Still required to complete the calculation: rated capacity S, impedance voltage uₖ, short-time or peak withstand current.

Per-model values (P0 / Pk / uₖ declared by the factory, losses, noise, temperature rise, dimensions, weight) are not in the product library: those rows stay at an em dash until the factory parameter sheet is supplied. An em dash means the value is unavailable — it is never rendered as zero.

Reference prices are for estimation only and do not constitute a formal offer.

3 · Get this quote

We will reply with your latest quote instantly.