QDTB® Transformer

Product Search

Find the right transformer for your needs

XGN2 Series High Voltage Switchgear

8 Models available

XGN2 High Voltage Switchgear

Images are for illustration purposes only

XGN2 Series - Fixed-Type High Voltage Switchgear

The XGN2 series fixed-type HV switchgear provides an economical alternative to withdrawable type switchgear for industrial power distribution and substation applications. Features robust fixed installation design with reliable circuit breaker integration.

Model Number Breakdown

2Design series number
XSwitchgear (Xinggaoqi)
GFixed type (Guding)
NIndoor use (Nei)

Applications

1

Industrial power distribution substations

2

Utility distribution switchrooms

3

Commercial building power supply

4

Infrastructure power systems

Key Features

  • Fixed-type construction for cost savings
  • Suitable for 12kV power distribution
  • Multiple current ratings (630A to 1250A)
  • Economical alternative to withdrawable switchgear

Specifications Range

All specifications and dimensions can be customized upon request

Model Selector

Key parametersModel Range
Rated Voltage12
Rated Current630–2500 A
Breaking Current25–31.5 kA
Short-time Withstand Current25–31.5 kA
Protection LevelIP4X
Mechanical Life10000 ops
Operating MechanismSpring-operated (integrated VCB)
StandardGB3906, IEC 62271-200
Select 2-3 models to compare
CompareModelSeriesRated voltage (kV)Current (A)Frequency (Hz)StandardWeightDimensions
XGN2-12/630-25XGN21263050GB3906, IEC 62271-200800 kg900×1500×2300 mm
XGN2-12/630-31.5XGN21263050GB3906, IEC 62271-200800 kg900×1500×2300 mm
XGN2-12/1250-25XGN212125050GB3906, IEC 62271-200800 kg900×1500×2300 mm
XGN2-12/1250-31.5XGN212125050GB3906, IEC 62271-200800 kg900×1500×2300 mm
XGN2-12/2000-25XGN212200050GB3906, IEC 62271-200800 kg900×1500×2300 mm
XGN2-12/2000-31.5XGN212200050GB3906, IEC 62271-200800 kg900×1500×2300 mm
XGN2-12/2500-25XGN212250050GB3906, IEC 62271-200800 kg900×1500×2300 mm
XGN2-12/2500-31.5XGN212250050GB3906, IEC 62271-200800 kg900×1500×2300 mm

Product Drawing

High Voltage Switchgear - XGN2-12/630-25

APPEARANCE — METAL-CLAD CABINET
HV SWITCHGEAR — FRONT VIEWpressure reliefrelay / meter panelbreaker view windowcable compartmentXGN2-12/630-25
STRUCTURE — THREE COMPARTMENTS
BUSBAR ROOMBREAKER TRUCKwithdrawableCABLE ROOMXGN2-12/630-25
MAIN CIRCUIT — SINGLE-LINE
HV SWITCHGEAR — MAIN CIRCUITBUSCTgroundPTCABLE OUTXGN2-12/630-25
SWITCHGEAR LINE-UP
SWITCHGEAR LINE-UP (INCOMING + FEEDERS)INF1F2F3common busbarXGN2-12/630-25

Note: This is a general product illustration. For detailed technical drawings and specifications, please contact our engineering team.

Instant Selection & Quote Calculator

Select your specifications to get an estimated price instantly.

1 · Configure
More options(5)
Certification
2 · Your price
Derived Ratings (calculated from the configuration)

The values below are computed from what you selected above. Anything that cannot be computed yet is shown as an em dash — never as zero.

Iₙ = S / (√3·U) · I_sc = 100·Iₙ / uₖ · S_sc = √3·U·I_sc · I_p = k·Iₖ

Inputs taken from the configuration
System voltage: not specified
Short-time withstand current: not specified
Peak withstand current: not specified
Switchgear system basis: HV switchgear — IEC 62271-1
Frequency: —
Result
Short-time withstand current Iₖ / I_cw—
Peak withstand current I_p / I_pk—
Peak factor k—
System voltage → —

Still required to complete the calculation: rated capacity S, impedance voltage uₖ, short-time or peak withstand current.

Per-model values (P0 / Pk / uₖ declared by the factory, losses, noise, temperature rise, dimensions, weight) are not in the product library: those rows stay at an em dash until the factory parameter sheet is supplied. An em dash means the value is unavailable — it is never rendered as zero.

Reference prices are for estimation only and do not constitute a formal offer.

3 · Get this quote