SL11 Series - Oil-Immersed Transformers with Aluminum Winding (Level 11 Efficiency)
The SL11 series features aluminum winding construction with Level 11 energy efficiency, offering cost-effective solutions for power distribution. Rated 10–5000 kVA, 0.48–35 kV primary and 0.208–0.48 kV secondary, mineral-oil insulation with 65 K temperature rise. Suitable for utility distribution networks, substations, solar farms, and industrial power systems.
Model Number Breakdown
Key Features
- Level 11 energy efficiency rating
- Cost-effective aluminum winding
- Lightweight design
- Reliable performance
Applications
- Budget-conscious projects
- General power distribution
- Rural electrification
- Light industrial applications
TECHNICAL DRAWING
Model: SL11-M-250/10/0.48 | Type: Oil-immersed transformer | Capacity: 250 kVA
FRONT ELEVATION
ELECTRICAL SCHEMATIC
EFFICIENCY vs LOAD
SIDE VIEW
TOP VIEW
TERMINAL BLOCK
CORE & WINDING
LEGEND:
Specifications Range
All specifications and dimensions can be customized upon request
Model Selector
| Key parameters | Model Range |
|---|---|
| Capacity | 10–5000 kVA |
| HV Voltage (kV) | 10, 6, 35, 0.48 |
| LV Voltage (kV) | 0.4, 0.48, 0.22, 0.208 |
| Frequency (Hz) | 50, 60 |
| Impedance (%) | 4, 4.5, 6, 7 |
| Cooling | ONAN |
| Efficiency | Class 1 |
| Standard | IEC 60076, IEEE C57 / ANSI C84.1 |
| Connection | Dyn11 (IEC), Delta-Wye (IEEE Std) |
| Insulation class | A (105°C) |
| Allowed temperature rise | 65 |
| Noise level | ≤33 dB(A), ≤34 dB(A), ≤35 dB(A), ≤36 dB(A), ≤37 dB(A), ≤38 dB(A)… |
| Tap Changer | ±2×2.5% Multi-tap, ±5% Single-tap, ±5×2.5% Multi-tap |
| No-load loss | 57–3892 W |
| Load loss | 330–38786 W |
| Compare | Model | Capacity (kVA) | HV Voltage (kV) | LV Voltage (kV) | Weight | Dimensions |
|---|---|---|---|---|---|---|
| SL11-M-10/10/0.4 | 10kVA | 10 | 0.4 | 221 kg | 496×340×686 mm | |
| SL11-M-10/6/0.4 | 10kVA | 6 | 0.4 | 221 kg | 496×340×686 mm | |
| SL11-M-10/35/0.4 | 10kVA | 35 | 0.4 | 221 kg | 496×340×686 mm | |
| SL11-M-10/10/0.48 | 10kVA | 10 | 0.48 | 221 kg | 496×340×686 mm | |
| SL11-M-10/10/0.22 | 10kVA | 10 | 0.22 | 221 kg | 496×340×686 mm | |
| SL11-M-10/0.48/0.208 | 10kVA | 0.48 | 0.208 | 221 kg | 496×340×686 mm | |
| SL11-M-15/10/0.4 | 15kVA | 10 | 0.4 | 238.6 kg | 516×359×708 mm | |
| SL11-M-15/6/0.4 | 15kVA | 6 | 0.4 | 238.6 kg | 516×359×708 mm | |
| SL11-M-15/35/0.4 | 15kVA | 35 | 0.4 | 238.6 kg | 516×359×708 mm | |
| SL11-M-15/10/0.48 | 15kVA | 10 | 0.48 | 238.6 kg | 516×359×708 mm | |
| SL11-M-15/10/0.22 | 15kVA | 10 | 0.22 | 238.6 kg | 516×359×708 mm | |
| SL11-M-15/0.48/0.208 | 15kVA | 0.48 | 0.208 | 238.6 kg | 516×359×708 mm | |
| SL11-M-20/10/0.4 | 20kVA | 10 | 0.4 | 256 kg | 535×377×731 mm | |
| SL11-M-20/6/0.4 | 20kVA | 6 | 0.4 | 256 kg | 535×377×731 mm | |
| SL11-M-20/35/0.4 | 20kVA | 35 | 0.4 | 256 kg | 535×377×731 mm | |
| SL11-M-20/10/0.48 | 20kVA | 10 | 0.48 | 256 kg | 535×377×731 mm | |
| SL11-M-20/10/0.22 | 20kVA | 10 | 0.22 | 256 kg | 535×377×731 mm | |
| SL11-M-20/0.48/0.208 | 20kVA | 0.48 | 0.208 | 256 kg | 535×377×731 mm | |
| SL11-M-25/10/0.4 | 25kVA | 10 | 0.4 | 278 kg | 600×415×754 mm | |
| SL11-M-25/6/0.4 | 25kVA | 6 | 0.4 | 278 kg | 600×415×754 mm | |
| SL11-M-25/35/0.4 | 25kVA | 35 | 0.4 | 278 kg | 600×415×754 mm | |
| SL11-M-25/10/0.48 | 25kVA | 10 | 0.48 | 278 kg | 600×415×754 mm | |
| SL11-M-25/10/0.22 | 25kVA | 10 | 0.22 | 278 kg | 600×415×754 mm | |
| SL11-M-25/0.48/0.208 | 25kVA | 0.48 | 0.208 | 278 kg | 600×415×754 mm | |
| SL11-M-30/10/0.4 | 30kVA | 10 | 0.4 | 300 kg | 664×453×777 mm | |
| SL11-M-30/6/0.4 | 30kVA | 6 | 0.4 | 300 kg | 664×453×777 mm | |
| SL11-M-30/35/0.4 | 30kVA | 35 | 0.4 | 300 kg | 664×453×777 mm | |
| SL11-M-30/10/0.48 | 30kVA | 10 | 0.48 | 300 kg | 664×453×777 mm | |
| SL11-M-30/10/0.22 | 30kVA | 10 | 0.22 | 300 kg | 664×453×777 mm | |
| SL11-M-30/0.48/0.208 | 30kVA | 0.48 | 0.208 | 300 kg | 664×453×777 mm | |
| SL11-M-40/10/0.4 | 40kVA | 10 | 0.4 | 358 kg | 676×460×800 mm | |
| SL11-M-40/6/0.4 | 40kVA | 6 | 0.4 | 358 kg | 676×460×800 mm | |
| SL11-M-40/35/0.4 | 40kVA | 35 | 0.4 | 358 kg | 676×460×800 mm | |
| SL11-M-40/10/0.48 | 40kVA | 10 | 0.48 | 358 kg | 676×460×800 mm | |
| SL11-M-40/10/0.22 | 40kVA | 10 | 0.22 | 358 kg | 676×460×800 mm | |
| SL11-M-40/0.48/0.208 | 40kVA | 0.48 | 0.208 | 358 kg | 676×460×800 mm | |
| SL11-M-50/10/0.4 | 50kVA | 10 | 0.4 | 415 kg | 687×468×823 mm | |
| SL11-M-50/6/0.4 | 50kVA | 6 | 0.4 | 415 kg | 687×468×823 mm | |
| SL11-M-50/35/0.4 | 50kVA | 35 | 0.4 | 415 kg | 687×468×823 mm | |
| SL11-M-50/10/0.48 | 50kVA | 10 | 0.48 | 415 kg | 687×468×823 mm | |
| SL11-M-50/10/0.22 | 50kVA | 10 | 0.22 | 415 kg | 687×468×823 mm | |
| SL11-M-50/0.48/0.208 | 50kVA | 0.48 | 0.208 | 415 kg | 687×468×823 mm | |
| SL11-M-63/10/0.4 | 63kVA | 10 | 0.4 | 464 kg | 722×487×864 mm | |
| SL11-M-63/6/0.4 | 63kVA | 6 | 0.4 | 464 kg | 722×487×864 mm | |
| SL11-M-63/35/0.4 | 63kVA | 35 | 0.4 | 464 kg | 722×487×864 mm | |
| SL11-M-63/10/0.48 | 63kVA | 10 | 0.48 | 464 kg | 722×487×864 mm | |
| SL11-M-63/10/0.22 | 63kVA | 10 | 0.22 | 464 kg | 722×487×864 mm | |
| SL11-M-63/0.48/0.208 | 63kVA | 0.48 | 0.208 | 464 kg | 722×487×864 mm | |
| SL11-M-80/10/0.4 | 80kVA | 10 | 0.4 | 530 kg | 764×513×914 mm | |
| SL11-M-80/6/0.4 | 80kVA | 6 | 0.4 | 530 kg | 764×513×914 mm | |
| SL11-M-80/35/0.4 | 80kVA | 35 | 0.4 | 530 kg | 764×513×914 mm | |
| SL11-M-80/10/0.48 | 80kVA | 10 | 0.48 | 530 kg | 764×513×914 mm | |
| SL11-M-80/10/0.22 | 80kVA | 10 | 0.22 | 530 kg | 764×513×914 mm | |
| SL11-M-80/0.48/0.208 | 80kVA | 0.48 | 0.208 | 530 kg | 764×513×914 mm | |
| SL11-M-100/10/0.4 | 100kVA | 10 | 0.4 | 586 kg | 800×650×1090 mm | |
| SL11-M-100/6/0.4 | 100kVA | 6 | 0.4 | 586 kg | 800×650×1090 mm | |
| SL11-M-100/35/0.4 | 100kVA | 35 | 0.4 | 586 kg | 800×650×1090 mm | |
| SL11-M-100/10/0.48 | 100kVA | 10 | 0.48 | 586 kg | 800×650×1090 mm | |
| SL11-M-100/10/0.22 | 100kVA | 10 | 0.22 | 586 kg | 800×650×1090 mm | |
| SL11-M-100/0.48/0.208 | 100kVA | 0.48 | 0.208 | 586 kg | 800×650×1090 mm | |
| SL11-M-125/10/0.4 | 125kVA | 10 | 0.4 | 645 kg | 825×543×1006 mm | |
| SL11-M-125/6/0.4 | 125kVA | 6 | 0.4 | 645 kg | 825×543×1006 mm | |
| SL11-M-125/35/0.4 | 125kVA | 35 | 0.4 | 645 kg | 825×543×1006 mm | |
| SL11-M-125/10/0.48 | 125kVA | 10 | 0.48 | 645 kg | 825×543×1006 mm | |
| SL11-M-125/10/0.22 | 125kVA | 10 | 0.22 | 645 kg | 825×543×1006 mm | |
| SL11-M-125/0.48/0.208 | 125kVA | 0.48 | 0.208 | 645 kg | 825×543×1006 mm | |
| SL11-M-160/10/0.4 | 160kVA | 10 | 0.4 | 739 kg | 840×710×1160 mm | |
| SL11-M-160/6/0.4 | 160kVA | 6 | 0.4 | 739 kg | 840×710×1160 mm | |
| SL11-M-160/35/0.4 | 160kVA | 35 | 0.4 | 739 kg | 840×710×1160 mm | |
| SL11-M-160/10/0.48 | 160kVA | 10 | 0.48 | 739 kg | 840×710×1160 mm | |
| SL11-M-160/10/0.22 | 160kVA | 10 | 0.22 | 739 kg | 840×710×1160 mm | |
| SL11-M-160/0.48/0.208 | 160kVA | 0.48 | 0.208 | 739 kg | 840×710×1160 mm | |
| SL11-M-200/10/0.4 | 200kVA | 10 | 0.4 | 830 kg | 880×750×1140 mm | |
| SL11-M-200/6/0.4 | 200kVA | 6 | 0.4 | 830 kg | 880×750×1140 mm | |
| SL11-M-200/35/0.4 | 200kVA | 35 | 0.4 | 830 kg | 880×750×1140 mm | |
| SL11-M-200/10/0.48 | 200kVA | 10 | 0.48 | 830 kg | 880×750×1140 mm | |
| SL11-M-200/10/0.22 | 200kVA | 10 | 0.22 | 830 kg | 880×750×1140 mm | |
| SL11-M-200/0.48/0.208 | 200kVA | 0.48 | 0.208 | 830 kg | 880×750×1140 mm | |
| SL11-M-250/10/0.4 | 250kVA | 10 | 0.4 | 928 kg | 909×777×1188 mm | |
| SL11-M-250/6/0.4 | 250kVA | 6 | 0.4 | 928 kg | 909×777×1188 mm | |
| SL11-M-250/35/0.4 | 250kVA | 35 | 0.4 | 928 kg | 909×777×1188 mm | |
| SL11-M-250/10/0.48 | 250kVA | 10 | 0.48 | 928 kg | 909×777×1188 mm | |
| SL11-M-250/10/0.22 | 250kVA | 10 | 0.22 | 928 kg | 909×777×1188 mm | |
| SL11-M-250/0.48/0.208 | 250kVA | 0.48 | 0.208 | 928 kg | 909×777×1188 mm | |
| SL11-M-315/10/0.4 | 315kVA | 10 | 0.4 | 1059 kg | 910×830×1270 mm | |
| SL11-M-315/6/0.4 | 315kVA | 6 | 0.4 | 1059 kg | 910×830×1270 mm | |
| SL11-M-315/35/0.4 | 315kVA | 35 | 0.4 | 1059 kg | 910×830×1270 mm | |
| SL11-M-315/10/0.48 | 315kVA | 10 | 0.48 | 1059 kg | 910×830×1270 mm | |
| SL11-M-315/10/0.22 | 315kVA | 10 | 0.22 | 1059 kg | 910×830×1270 mm | |
| SL11-M-315/0.48/0.208 | 315kVA | 0.48 | 0.208 | 1059 kg | 910×830×1270 mm | |
| SL11-M-400/10/0.4 | 400kVA | 10 | 0.4 | 1278 kg | 980×920×1310 mm | |
| SL11-M-400/6/0.4 | 400kVA | 6 | 0.4 | 1278 kg | 980×920×1310 mm | |
| SL11-M-400/35/0.4 | 400kVA | 35 | 0.4 | 1278 kg | 980×920×1310 mm | |
| SL11-M-400/10/0.48 | 400kVA | 10 | 0.48 | 1278 kg | 980×920×1310 mm | |
| SL11-M-400/10/0.22 | 400kVA | 10 | 0.22 | 1278 kg | 980×920×1310 mm | |
| SL11-M-400/0.48/0.208 | 400kVA | 0.48 | 0.208 | 1278 kg | 980×920×1310 mm | |
| SL11-M-500/10/0.4 | 500kVA | 10 | 0.4 | 1450 kg | 1030×930×1340 mm | |
| SL11-M-500/6/0.4 | 500kVA | 6 | 0.4 | 1450 kg | 1030×930×1340 mm | |
| SL11-M-500/35/0.4 | 500kVA | 35 | 0.4 | 1450 kg | 1030×930×1340 mm | |
| SL11-M-500/10/0.48 | 500kVA | 10 | 0.48 | 1450 kg | 1030×930×1340 mm | |
| SL11-M-500/10/0.22 | 500kVA | 10 | 0.22 | 1450 kg | 1030×930×1340 mm | |
| SL11-M-500/0.48/0.208 | 500kVA | 0.48 | 0.208 | 1450 kg | 1030×930×1340 mm | |
| SL11-M-630/10/0.4 | 630kVA | 10 | 0.4 | 1706 kg | 1340×850×1410 mm | |
| SL11-M-630/6/0.4 | 630kVA | 6 | 0.4 | 1706 kg | 1340×850×1410 mm | |
| SL11-M-630/35/0.4 | 630kVA | 35 | 0.4 | 1706 kg | 1340×850×1410 mm | |
| SL11-M-630/10/0.48 | 630kVA | 10 | 0.48 | 1706 kg | 1340×850×1410 mm | |
| SL11-M-630/10/0.22 | 630kVA | 10 | 0.22 | 1706 kg | 1340×850×1410 mm | |
| SL11-M-630/0.48/0.208 | 630kVA | 0.48 | 0.208 | 1706 kg | 1340×850×1410 mm | |
| SL11-M-800/10/0.4 | 800kVA | 10 | 0.4 | 2029 kg | 1500×1060×1340 mm | |
| SL11-M-800/6/0.4 | 800kVA | 6 | 0.4 | 2029 kg | 1500×1060×1340 mm | |
| SL11-M-800/35/0.4 | 800kVA | 35 | 0.4 | 2029 kg | 1500×1060×1340 mm | |
| SL11-M-800/10/0.48 | 800kVA | 10 | 0.48 | 2029 kg | 1500×1060×1340 mm | |
| SL11-M-800/10/0.22 | 800kVA | 10 | 0.22 | 2029 kg | 1500×1060×1340 mm | |
| SL11-M-800/0.48/0.208 | 800kVA | 0.48 | 0.208 | 2029 kg | 1500×1060×1340 mm | |
| SL11-M-1000/10/0.4 | 1000kVA | 10 | 0.4 | 2294 kg | 1650×1090×1380 mm | |
| SL11-M-1000/6/0.4 | 1000kVA | 6 | 0.4 | 2294 kg | 1650×1090×1380 mm | |
| SL11-M-1000/35/0.4 | 1000kVA | 35 | 0.4 | 2294 kg | 1650×1090×1380 mm | |
| SL11-M-1000/10/0.48 | 1000kVA | 10 | 0.48 | 2294 kg | 1650×1090×1380 mm | |
| SL11-M-1000/10/0.22 | 1000kVA | 10 | 0.22 | 2294 kg | 1650×1090×1380 mm | |
| SL11-M-1000/0.48/0.208 | 1000kVA | 0.48 | 0.208 | 2294 kg | 1650×1090×1380 mm | |
| SL11-M-1250/10/0.4 | 1250kVA | 10 | 0.4 | 2698 kg | 1640×1150×1490 mm | |
| SL11-M-1250/6/0.4 | 1250kVA | 6 | 0.4 | 2698 kg | 1640×1150×1490 mm | |
| SL11-M-1250/35/0.4 | 1250kVA | 35 | 0.4 | 2698 kg | 1640×1150×1490 mm | |
| SL11-M-1250/10/0.48 | 1250kVA | 10 | 0.48 | 2698 kg | 1640×1150×1490 mm | |
| SL11-M-1250/10/0.22 | 1250kVA | 10 | 0.22 | 2698 kg | 1640×1150×1490 mm | |
| SL11-M-1250/0.48/0.208 | 1250kVA | 0.48 | 0.208 | 2698 kg | 1640×1150×1490 mm | |
| SL11-M-1600/10/0.4 | 1600kVA | 10 | 0.4 | 3932 kg | 1436×1230×1773 mm | |
| SL11-M-1600/6/0.4 | 1600kVA | 6 | 0.4 | 3932 kg | 1436×1230×1773 mm | |
| SL11-M-1600/35/0.4 | 1600kVA | 35 | 0.4 | 3932 kg | 1436×1230×1773 mm | |
| SL11-M-1600/10/0.48 | 1600kVA | 10 | 0.48 | 3932 kg | 1436×1230×1773 mm | |
| SL11-M-1600/10/0.22 | 1600kVA | 10 | 0.22 | 3932 kg | 1436×1230×1773 mm | |
| SL11-M-1600/0.48/0.208 | 1600kVA | 0.48 | 0.208 | 3932 kg | 1436×1230×1773 mm | |
| SL11-M-2000/10/0.4 | 2000kVA | 10 | 0.4 | 4418 kg | 1528×1283×1828 mm | |
| SL11-M-2000/6/0.4 | 2000kVA | 6 | 0.4 | 4418 kg | 1528×1283×1828 mm | |
| SL11-M-2000/35/0.4 | 2000kVA | 35 | 0.4 | 4418 kg | 1528×1283×1828 mm | |
| SL11-M-2000/10/0.48 | 2000kVA | 10 | 0.48 | 4418 kg | 1528×1283×1828 mm | |
| SL11-M-2000/10/0.22 | 2000kVA | 10 | 0.22 | 4418 kg | 1528×1283×1828 mm | |
| SL11-M-2000/0.48/0.208 | 2000kVA | 0.48 | 0.208 | 4418 kg | 1528×1283×1828 mm | |
| SL11-M-2500/10/0.4 | 2500kVA | 10 | 0.4 | 5125 kg | 1665×996×1801 mm | |
| SL11-M-2500/6/0.4 | 2500kVA | 6 | 0.4 | 5125 kg | 1665×996×1801 mm | |
| SL11-M-2500/35/0.4 | 2500kVA | 35 | 0.4 | 5125 kg | 1665×996×1801 mm | |
| SL11-M-2500/10/0.48 | 2500kVA | 10 | 0.48 | 5125 kg | 1665×996×1801 mm | |
| SL11-M-2500/10/0.22 | 2500kVA | 10 | 0.22 | 5125 kg | 1665×996×1801 mm | |
| SL11-M-2500/0.48/0.208 | 2500kVA | 0.48 | 0.208 | 5125 kg | 1665×996×1801 mm | |
| SL11-M-3150/10/0.4 | 3150kVA | 10 | 0.4 | 6096.5 kg | 1757×1095×1920 mm | |
| SL11-M-3150/6/0.4 | 3150kVA | 6 | 0.4 | 6096.5 kg | 1757×1095×1920 mm | |
| SL11-M-3150/35/0.4 | 3150kVA | 35 | 0.4 | 6096.5 kg | 1757×1095×1920 mm | |
| SL11-M-3150/10/0.48 | 3150kVA | 10 | 0.48 | 6096.5 kg | 1757×1095×1920 mm | |
| SL11-M-3150/10/0.22 | 3150kVA | 10 | 0.22 | 6096.5 kg | 1757×1095×1920 mm | |
| SL11-M-3150/0.48/0.208 | 3150kVA | 0.48 | 0.208 | 6096.5 kg | 1757×1095×1920 mm | |
| SL11-M-4000/10/0.4 | 4000kVA | 10 | 0.4 | 7333.5 kg | 1909×1170×2057 mm | |
| SL11-M-4000/6/0.4 | 4000kVA | 6 | 0.4 | 7333.5 kg | 1909×1170×2057 mm | |
| SL11-M-4000/35/0.4 | 4000kVA | 35 | 0.4 | 7333.5 kg | 1909×1170×2057 mm | |
| SL11-M-4000/10/0.48 | 4000kVA | 10 | 0.48 | 7333.5 kg | 1909×1170×2057 mm | |
| SL11-M-4000/10/0.22 | 4000kVA | 10 | 0.22 | 7333.5 kg | 1909×1170×2057 mm | |
| SL11-M-4000/0.48/0.208 | 4000kVA | 0.48 | 0.208 | 7333.5 kg | 1909×1170×2057 mm | |
| SL11-M-5000/10/0.4 | 5000kVA | 10 | 0.4 | 8835.5 kg | 2062×1245×2194 mm | |
| SL11-M-5000/6/0.4 | 5000kVA | 6 | 0.4 | 8835.5 kg | 2062×1245×2194 mm | |
| SL11-M-5000/35/0.4 | 5000kVA | 35 | 0.4 | 8835.5 kg | 2062×1245×2194 mm | |
| SL11-M-5000/10/0.48 | 5000kVA | 10 | 0.48 | 8835.5 kg | 2062×1245×2194 mm | |
| SL11-M-5000/10/0.22 | 5000kVA | 10 | 0.22 | 8835.5 kg | 2062×1245×2194 mm | |
| SL11-M-5000/0.48/0.208 | 5000kVA | 0.48 | 0.208 | 8835.5 kg | 2062×1245×2194 mm |
Instant Selection & Quote Calculator
Select your specifications to get an estimated price instantly.
More options(6)
Certification
The values below are computed from what you selected above. Anything that cannot be computed yet is shown as an em dash — never as zero.
Iₙ = S / (√3·U) · I_sc = 100·Iₙ / uₖ · S_sc = √3·U·I_sc · I_p = k·Iₖ
Still required to complete the calculation: rated capacity S, impedance voltage uₖ, short-time or peak withstand current.
Per-model values (P0 / Pk / uₖ declared by the factory, losses, noise, temperature rise, dimensions, weight) are not in the product library: those rows stay at an em dash until the factory parameter sheet is supplied. An em dash means the value is unavailable — it is never rendered as zero.
Read-only: no price factor, not part of the sum — the loss-grade cost is already carried by the efficiency (subtype) base price, so charging here would double-bill. Values come from the product library type-test data, interpolated between published capacities; grades the library does not cover show an em dash, never zero.
S13 系列(产品库 S13-M / 卷铁芯 S13-M.RL,Class 3)
Reference prices are for estimation only and do not constitute a formal offer.
3 · Get this quote
We will reply with your latest quote instantly.
Related Engineering Calculators
Free sizing and pricing tools for this product category.