Product Search
Find the right transformer for your needs

Images are for illustration purposes only
SL11 Series - Oil-Immersed Transformers with Aluminum Winding (Level 11 Efficiency)
The SL11 series features aluminum winding construction with Level 11 energy efficiency, offering cost-effective solutions for power distribution. Rated 10–5000 kVA, 0.48–35 kV primary and 0.208–0.48 kV secondary, mineral-oil insulation with 65 K temperature rise. Suitable for utility distribution networks, substations, solar farms, and industrial power systems.
Model Number Breakdown
Key Features
- Level 11 energy efficiency rating
- Cost-effective aluminum winding
- Lightweight design
- Reliable performance
Applications
- Budget-conscious projects
- General power distribution
- Rural electrification
- Light industrial applications
TECHNICAL DRAWING
Model: SL11-M-250/10/0.48 | Type: Oil-immersed transformer | Capacity: 250 kVA
FRONT ELEVATION
ELECTRICAL SCHEMATIC
EFFICIENCY vs LOAD
SIDE VIEW
TOP VIEW
TERMINAL BLOCK
CORE & WINDING
LEGEND:
Specifications Range
All specifications and dimensions can be customized upon request
Model Selector
| Key parameters | Model Range |
|---|---|
| Capacity | 10–5000 kVA |
| HV Voltage (kV) | 10, 6, 35, 0.48 |
| LV Voltage (kV) | 0.4, 0.48, 0.22, 0.208 |
| Frequency (Hz) | 50, 60 |
| Impedance (%) | 4, 4.5, 6, 7 |
| Cooling | ONAN |
| Efficiency | Class 1 |
| Standard | IEC 60076, IEEE C57 / ANSI C84.1 |
| Connection | Dyn11 (IEC), Delta-Wye (IEEE Std) |
| Insulation class | A (105°C) |
| Allowed temperature rise | 65 |
| Noise level | ≤33 dB(A), ≤34 dB(A), ≤35 dB(A), ≤36 dB(A), ≤37 dB(A), ≤38 dB(A)… |
| Tap Changer | ±2×2.5% Multi-tap, ±5% Single-tap, ±5×2.5% Multi-tap, ±8×1.25% OLTC |
| No-load loss | 57–3892 W |
| Load loss | 330–38786 W |
| Compare | Model | Capacity (kVA) | HV Voltage (kV) | LV Voltage (kV) | Weight | Dimensions |
|---|---|---|---|---|---|---|
| SL11-M-10/10/0.4 | 10kVA | 10 | 0.4 | 221 kg | 496×340×686 mm | |
| SL11-M-10/6/0.4 | 10kVA | 6 | 0.4 | 221 kg | 496×340×686 mm | |
| SL11-M-10/35/0.4 | 10kVA | 35 | 0.4 | 221 kg | 496×340×686 mm | |
| SL11-M-10/10/0.48 | 10kVA | 10 | 0.48 | 221 kg | 496×340×686 mm | |
| SL11-M-10/10/0.22 | 10kVA | 10 | 0.22 | 221 kg | 496×340×686 mm | |
| SL11-M-10/0.48/0.208 | 10kVA | 0.48 | 0.208 | 221 kg | 496×340×686 mm | |
| SL11-M-15/10/0.4 | 15kVA | 10 | 0.4 | 238.6 kg | 516×359×708 mm | |
| SL11-M-15/6/0.4 | 15kVA | 6 | 0.4 | 238.6 kg | 516×359×708 mm | |
| SL11-M-15/35/0.4 | 15kVA | 35 | 0.4 | 238.6 kg | 516×359×708 mm | |
| SL11-M-15/10/0.48 | 15kVA | 10 | 0.48 | 238.6 kg | 516×359×708 mm | |
| SL11-M-15/10/0.22 | 15kVA | 10 | 0.22 | 238.6 kg | 516×359×708 mm | |
| SL11-M-15/0.48/0.208 | 15kVA | 0.48 | 0.208 | 238.6 kg | 516×359×708 mm | |
| SL11-M-20/10/0.4 | 20kVA | 10 | 0.4 | 256 kg | 535×377×731 mm | |
| SL11-M-20/6/0.4 | 20kVA | 6 | 0.4 | 256 kg | 535×377×731 mm | |
| SL11-M-20/35/0.4 | 20kVA | 35 | 0.4 | 256 kg | 535×377×731 mm | |
| SL11-M-20/10/0.48 | 20kVA | 10 | 0.48 | 256 kg | 535×377×731 mm | |
| SL11-M-20/10/0.22 | 20kVA | 10 | 0.22 | 256 kg | 535×377×731 mm | |
| SL11-M-20/0.48/0.208 | 20kVA | 0.48 | 0.208 | 256 kg | 535×377×731 mm | |
| SL11-M-25/10/0.4 | 25kVA | 10 | 0.4 | 278 kg | 600×415×754 mm | |
| SL11-M-25/6/0.4 | 25kVA | 6 | 0.4 | 278 kg | 600×415×754 mm | |
| SL11-M-25/35/0.4 | 25kVA | 35 | 0.4 | 278 kg | 600×415×754 mm | |
| SL11-M-25/10/0.48 | 25kVA | 10 | 0.48 | 278 kg | 600×415×754 mm | |
| SL11-M-25/10/0.22 | 25kVA | 10 | 0.22 | 278 kg | 600×415×754 mm | |
| SL11-M-25/0.48/0.208 | 25kVA | 0.48 | 0.208 | 278 kg | 600×415×754 mm | |
| SL11-M-30/10/0.4 | 30kVA | 10 | 0.4 | 300 kg | 664×453×777 mm | |
| SL11-M-30/6/0.4 | 30kVA | 6 | 0.4 | 300 kg | 664×453×777 mm | |
| SL11-M-30/35/0.4 | 30kVA | 35 | 0.4 | 300 kg | 664×453×777 mm | |
| SL11-M-30/10/0.48 | 30kVA | 10 | 0.48 | 300 kg | 664×453×777 mm | |
| SL11-M-30/10/0.22 | 30kVA | 10 | 0.22 | 300 kg | 664×453×777 mm | |
| SL11-M-30/0.48/0.208 | 30kVA | 0.48 | 0.208 | 300 kg | 664×453×777 mm | |
| SL11-M-40/10/0.4 | 40kVA | 10 | 0.4 | 358 kg | 676×460×800 mm | |
| SL11-M-40/6/0.4 | 40kVA | 6 | 0.4 | 358 kg | 676×460×800 mm | |
| SL11-M-40/35/0.4 | 40kVA | 35 | 0.4 | 358 kg | 676×460×800 mm | |
| SL11-M-40/10/0.48 | 40kVA | 10 | 0.48 | 358 kg | 676×460×800 mm | |
| SL11-M-40/10/0.22 | 40kVA | 10 | 0.22 | 358 kg | 676×460×800 mm | |
| SL11-M-40/0.48/0.208 | 40kVA | 0.48 | 0.208 | 358 kg | 676×460×800 mm | |
| SL11-M-50/10/0.4 | 50kVA | 10 | 0.4 | 415 kg | 687×468×823 mm | |
| SL11-M-50/6/0.4 | 50kVA | 6 | 0.4 | 415 kg | 687×468×823 mm | |
| SL11-M-50/35/0.4 | 50kVA | 35 | 0.4 | 415 kg | 687×468×823 mm | |
| SL11-M-50/10/0.48 | 50kVA | 10 | 0.48 | 415 kg | 687×468×823 mm | |
| SL11-M-50/10/0.22 | 50kVA | 10 | 0.22 | 415 kg | 687×468×823 mm | |
| SL11-M-50/0.48/0.208 | 50kVA | 0.48 | 0.208 | 415 kg | 687×468×823 mm | |
| SL11-M-63/10/0.4 | 63kVA | 10 | 0.4 | 464 kg | 722×487×864 mm | |
| SL11-M-63/6/0.4 | 63kVA | 6 | 0.4 | 464 kg | 722×487×864 mm | |
| SL11-M-63/35/0.4 | 63kVA | 35 | 0.4 | 464 kg | 722×487×864 mm | |
| SL11-M-63/10/0.48 | 63kVA | 10 | 0.48 | 464 kg | 722×487×864 mm | |
| SL11-M-63/10/0.22 | 63kVA | 10 | 0.22 | 464 kg | 722×487×864 mm | |
| SL11-M-63/0.48/0.208 | 63kVA | 0.48 | 0.208 | 464 kg | 722×487×864 mm | |
| SL11-M-80/10/0.4 | 80kVA | 10 | 0.4 | 530 kg | 764×513×914 mm | |
| SL11-M-80/6/0.4 | 80kVA | 6 | 0.4 | 530 kg | 764×513×914 mm | |
| SL11-M-80/35/0.4 | 80kVA | 35 | 0.4 | 530 kg | 764×513×914 mm | |
| SL11-M-80/10/0.48 | 80kVA | 10 | 0.48 | 530 kg | 764×513×914 mm | |
| SL11-M-80/10/0.22 | 80kVA | 10 | 0.22 | 530 kg | 764×513×914 mm | |
| SL11-M-80/0.48/0.208 | 80kVA | 0.48 | 0.208 | 530 kg | 764×513×914 mm | |
| SL11-M-100/10/0.4 | 100kVA | 10 | 0.4 | 586 kg | 800×650×1090 mm | |
| SL11-M-100/6/0.4 | 100kVA | 6 | 0.4 | 586 kg | 800×650×1090 mm | |
| SL11-M-100/35/0.4 | 100kVA | 35 | 0.4 | 586 kg | 800×650×1090 mm | |
| SL11-M-100/10/0.48 | 100kVA | 10 | 0.48 | 586 kg | 800×650×1090 mm | |
| SL11-M-100/10/0.22 | 100kVA | 10 | 0.22 | 586 kg | 800×650×1090 mm | |
| SL11-M-100/0.48/0.208 | 100kVA | 0.48 | 0.208 | 586 kg | 800×650×1090 mm | |
| SL11-M-125/10/0.4 | 125kVA | 10 | 0.4 | 645 kg | 825×543×1006 mm | |
| SL11-M-125/6/0.4 | 125kVA | 6 | 0.4 | 645 kg | 825×543×1006 mm | |
| SL11-M-125/35/0.4 | 125kVA | 35 | 0.4 | 645 kg | 825×543×1006 mm | |
| SL11-M-125/10/0.48 | 125kVA | 10 | 0.48 | 645 kg | 825×543×1006 mm | |
| SL11-M-125/10/0.22 | 125kVA | 10 | 0.22 | 645 kg | 825×543×1006 mm | |
| SL11-M-125/0.48/0.208 | 125kVA | 0.48 | 0.208 | 645 kg | 825×543×1006 mm | |
| SL11-M-160/10/0.4 | 160kVA | 10 | 0.4 | 739 kg | 840×710×1160 mm | |
| SL11-M-160/6/0.4 | 160kVA | 6 | 0.4 | 739 kg | 840×710×1160 mm | |
| SL11-M-160/35/0.4 | 160kVA | 35 | 0.4 | 739 kg | 840×710×1160 mm | |
| SL11-M-160/10/0.48 | 160kVA | 10 | 0.48 | 739 kg | 840×710×1160 mm | |
| SL11-M-160/10/0.22 | 160kVA | 10 | 0.22 | 739 kg | 840×710×1160 mm | |
| SL11-M-160/0.48/0.208 | 160kVA | 0.48 | 0.208 | 739 kg | 840×710×1160 mm | |
| SL11-M-200/10/0.4 | 200kVA | 10 | 0.4 | 830 kg | 880×750×1140 mm | |
| SL11-M-200/6/0.4 | 200kVA | 6 | 0.4 | 830 kg | 880×750×1140 mm | |
| SL11-M-200/35/0.4 | 200kVA | 35 | 0.4 | 830 kg | 880×750×1140 mm | |
| SL11-M-200/10/0.48 | 200kVA | 10 | 0.48 | 830 kg | 880×750×1140 mm | |
| SL11-M-200/10/0.22 | 200kVA | 10 | 0.22 | 830 kg | 880×750×1140 mm | |
| SL11-M-200/0.48/0.208 | 200kVA | 0.48 | 0.208 | 830 kg | 880×750×1140 mm | |
| SL11-M-250/10/0.4 | 250kVA | 10 | 0.4 | 928 kg | 909×777×1188 mm | |
| SL11-M-250/6/0.4 | 250kVA | 6 | 0.4 | 928 kg | 909×777×1188 mm | |
| SL11-M-250/35/0.4 | 250kVA | 35 | 0.4 | 928 kg | 909×777×1188 mm | |
| SL11-M-250/10/0.48 | 250kVA | 10 | 0.48 | 928 kg | 909×777×1188 mm | |
| SL11-M-250/10/0.22 | 250kVA | 10 | 0.22 | 928 kg | 909×777×1188 mm | |
| SL11-M-250/0.48/0.208 | 250kVA | 0.48 | 0.208 | 928 kg | 909×777×1188 mm | |
| SL11-M-315/10/0.4 | 315kVA | 10 | 0.4 | 1059 kg | 910×830×1270 mm | |
| SL11-M-315/6/0.4 | 315kVA | 6 | 0.4 | 1059 kg | 910×830×1270 mm | |
| SL11-M-315/35/0.4 | 315kVA | 35 | 0.4 | 1059 kg | 910×830×1270 mm | |
| SL11-M-315/10/0.48 | 315kVA | 10 | 0.48 | 1059 kg | 910×830×1270 mm | |
| SL11-M-315/10/0.22 | 315kVA | 10 | 0.22 | 1059 kg | 910×830×1270 mm | |
| SL11-M-315/0.48/0.208 | 315kVA | 0.48 | 0.208 | 1059 kg | 910×830×1270 mm | |
| SL11-M-400/10/0.4 | 400kVA | 10 | 0.4 | 1278 kg | 980×920×1310 mm | |
| SL11-M-400/6/0.4 | 400kVA | 6 | 0.4 | 1278 kg | 980×920×1310 mm | |
| SL11-M-400/35/0.4 | 400kVA | 35 | 0.4 | 1278 kg | 980×920×1310 mm | |
| SL11-M-400/10/0.48 | 400kVA | 10 | 0.48 | 1278 kg | 980×920×1310 mm | |
| SL11-M-400/10/0.22 | 400kVA | 10 | 0.22 | 1278 kg | 980×920×1310 mm | |
| SL11-M-400/0.48/0.208 | 400kVA | 0.48 | 0.208 | 1278 kg | 980×920×1310 mm | |
| SL11-M-500/10/0.4 | 500kVA | 10 | 0.4 | 1450 kg | 1030×930×1340 mm | |
| SL11-M-500/6/0.4 | 500kVA | 6 | 0.4 | 1450 kg | 1030×930×1340 mm | |
| SL11-M-500/35/0.4 | 500kVA | 35 | 0.4 | 1450 kg | 1030×930×1340 mm | |
| SL11-M-500/10/0.48 | 500kVA | 10 | 0.48 | 1450 kg | 1030×930×1340 mm | |
| SL11-M-500/10/0.22 | 500kVA | 10 | 0.22 | 1450 kg | 1030×930×1340 mm | |
| SL11-M-500/0.48/0.208 | 500kVA | 0.48 | 0.208 | 1450 kg | 1030×930×1340 mm | |
| SL11-M-630/10/0.4 | 630kVA | 10 | 0.4 | 1706 kg | 1340×850×1410 mm | |
| SL11-M-630/6/0.4 | 630kVA | 6 | 0.4 | 1706 kg | 1340×850×1410 mm | |
| SL11-M-630/35/0.4 | 630kVA | 35 | 0.4 | 1706 kg | 1340×850×1410 mm | |
| SL11-M-630/10/0.48 | 630kVA | 10 | 0.48 | 1706 kg | 1340×850×1410 mm | |
| SL11-M-630/10/0.22 | 630kVA | 10 | 0.22 | 1706 kg | 1340×850×1410 mm | |
| SL11-M-630/0.48/0.208 | 630kVA | 0.48 | 0.208 | 1706 kg | 1340×850×1410 mm | |
| SL11-M-800/10/0.4 | 800kVA | 10 | 0.4 | 2029 kg | 1500×1060×1340 mm | |
| SL11-M-800/6/0.4 | 800kVA | 6 | 0.4 | 2029 kg | 1500×1060×1340 mm | |
| SL11-M-800/35/0.4 | 800kVA | 35 | 0.4 | 2029 kg | 1500×1060×1340 mm | |
| SL11-M-800/10/0.48 | 800kVA | 10 | 0.48 | 2029 kg | 1500×1060×1340 mm | |
| SL11-M-800/10/0.22 | 800kVA | 10 | 0.22 | 2029 kg | 1500×1060×1340 mm | |
| SL11-M-800/0.48/0.208 | 800kVA | 0.48 | 0.208 | 2029 kg | 1500×1060×1340 mm | |
| SL11-M-1000/10/0.4 | 1000kVA | 10 | 0.4 | 2294 kg | 1650×1090×1380 mm | |
| SL11-M-1000/6/0.4 | 1000kVA | 6 | 0.4 | 2294 kg | 1650×1090×1380 mm | |
| SL11-M-1000/35/0.4 | 1000kVA | 35 | 0.4 | 2294 kg | 1650×1090×1380 mm | |
| SL11-M-1000/10/0.48 | 1000kVA | 10 | 0.48 | 2294 kg | 1650×1090×1380 mm | |
| SL11-M-1000/10/0.22 | 1000kVA | 10 | 0.22 | 2294 kg | 1650×1090×1380 mm | |
| SL11-M-1000/0.48/0.208 | 1000kVA | 0.48 | 0.208 | 2294 kg | 1650×1090×1380 mm | |
| SL11-M-1250/10/0.4 | 1250kVA | 10 | 0.4 | 2698 kg | 1640×1150×1490 mm | |
| SL11-M-1250/6/0.4 | 1250kVA | 6 | 0.4 | 2698 kg | 1640×1150×1490 mm | |
| SL11-M-1250/35/0.4 | 1250kVA | 35 | 0.4 | 2698 kg | 1640×1150×1490 mm | |
| SL11-M-1250/10/0.48 | 1250kVA | 10 | 0.48 | 2698 kg | 1640×1150×1490 mm | |
| SL11-M-1250/10/0.22 | 1250kVA | 10 | 0.22 | 2698 kg | 1640×1150×1490 mm | |
| SL11-M-1250/0.48/0.208 | 1250kVA | 0.48 | 0.208 | 2698 kg | 1640×1150×1490 mm | |
| SL11-M-1600/10/0.4 | 1600kVA | 10 | 0.4 | 3932 kg | 1436×1230×1773 mm | |
| SL11-M-1600/6/0.4 | 1600kVA | 6 | 0.4 | 3932 kg | 1436×1230×1773 mm | |
| SL11-M-1600/35/0.4 | 1600kVA | 35 | 0.4 | 3932 kg | 1436×1230×1773 mm | |
| SL11-M-1600/10/0.48 | 1600kVA | 10 | 0.48 | 3932 kg | 1436×1230×1773 mm | |
| SL11-M-1600/10/0.22 | 1600kVA | 10 | 0.22 | 3932 kg | 1436×1230×1773 mm | |
| SL11-M-1600/0.48/0.208 | 1600kVA | 0.48 | 0.208 | 3932 kg | 1436×1230×1773 mm | |
| SL11-M-2000/10/0.4 | 2000kVA | 10 | 0.4 | 4418 kg | 1528×1283×1828 mm | |
| SL11-M-2000/6/0.4 | 2000kVA | 6 | 0.4 | 4418 kg | 1528×1283×1828 mm | |
| SL11-M-2000/35/0.4 | 2000kVA | 35 | 0.4 | 4418 kg | 1528×1283×1828 mm | |
| SL11-M-2000/10/0.48 | 2000kVA | 10 | 0.48 | 4418 kg | 1528×1283×1828 mm | |
| SL11-M-2000/10/0.22 | 2000kVA | 10 | 0.22 | 4418 kg | 1528×1283×1828 mm | |
| SL11-M-2000/0.48/0.208 | 2000kVA | 0.48 | 0.208 | 4418 kg | 1528×1283×1828 mm | |
| SL11-M-2500/10/0.4 | 2500kVA | 10 | 0.4 | 5125 kg | 1665×996×1801 mm | |
| SL11-M-2500/6/0.4 | 2500kVA | 6 | 0.4 | 5125 kg | 1665×996×1801 mm | |
| SL11-M-2500/35/0.4 | 2500kVA | 35 | 0.4 | 5125 kg | 1665×996×1801 mm | |
| SL11-M-2500/10/0.48 | 2500kVA | 10 | 0.48 | 5125 kg | 1665×996×1801 mm | |
| SL11-M-2500/10/0.22 | 2500kVA | 10 | 0.22 | 5125 kg | 1665×996×1801 mm | |
| SL11-M-2500/0.48/0.208 | 2500kVA | 0.48 | 0.208 | 5125 kg | 1665×996×1801 mm | |
| SL11-M-3150/10/0.4 | 3150kVA | 10 | 0.4 | 6096.5 kg | 1757×1095×1920 mm | |
| SL11-M-3150/6/0.4 | 3150kVA | 6 | 0.4 | 6096.5 kg | 1757×1095×1920 mm | |
| SL11-M-3150/35/0.4 | 3150kVA | 35 | 0.4 | 6096.5 kg | 1757×1095×1920 mm | |
| SL11-M-3150/10/0.48 | 3150kVA | 10 | 0.48 | 6096.5 kg | 1757×1095×1920 mm | |
| SL11-M-3150/10/0.22 | 3150kVA | 10 | 0.22 | 6096.5 kg | 1757×1095×1920 mm | |
| SL11-M-3150/0.48/0.208 | 3150kVA | 0.48 | 0.208 | 6096.5 kg | 1757×1095×1920 mm | |
| SL11-M-4000/10/0.4 | 4000kVA | 10 | 0.4 | 7333.5 kg | 1909×1170×2057 mm | |
| SL11-M-4000/6/0.4 | 4000kVA | 6 | 0.4 | 7333.5 kg | 1909×1170×2057 mm | |
| SL11-M-4000/35/0.4 | 4000kVA | 35 | 0.4 | 7333.5 kg | 1909×1170×2057 mm | |
| SL11-M-4000/10/0.48 | 4000kVA | 10 | 0.48 | 7333.5 kg | 1909×1170×2057 mm | |
| SL11-M-4000/10/0.22 | 4000kVA | 10 | 0.22 | 7333.5 kg | 1909×1170×2057 mm | |
| SL11-M-4000/0.48/0.208 | 4000kVA | 0.48 | 0.208 | 7333.5 kg | 1909×1170×2057 mm | |
| SL11-M-5000/10/0.4 | 5000kVA | 10 | 0.4 | 8835.5 kg | 2062×1245×2194 mm | |
| SL11-M-5000/6/0.4 | 5000kVA | 6 | 0.4 | 8835.5 kg | 2062×1245×2194 mm | |
| SL11-M-5000/35/0.4 | 5000kVA | 35 | 0.4 | 8835.5 kg | 2062×1245×2194 mm | |
| SL11-M-5000/10/0.48 | 5000kVA | 10 | 0.48 | 8835.5 kg | 2062×1245×2194 mm | |
| SL11-M-5000/10/0.22 | 5000kVA | 10 | 0.22 | 8835.5 kg | 2062×1245×2194 mm | |
| SL11-M-5000/0.48/0.208 | 5000kVA | 0.48 | 0.208 | 8835.5 kg | 2062×1245×2194 mm |
Instant Selection & Quote Calculator
Select your specifications to get an estimated price instantly.
| Base price (interpolation) | $2,332 |
| × Product factor | ×1.0000 |
| × Country factor | ×1.0000 |
| × Copper-linked factor | ×1.0000 |
| + Options / accessories | $0 |
Aluminum winding — no copper linkage
Reference prices are for estimation only and do not constitute a formal offer.
We will reply with your latest quote instantly.
Related Engineering Calculators
Free sizing and pricing tools for this product category.