QDTB® Transformer

SL11-M-1600/10/0.48

SL11 Series • 1600kVA • 10/0.48 kV

SL11-M-1600/10/0.48 is a 1600 kVA, 10/0.48 kV oil-immersed transformer manufactured by Shandong Yaqing Electric Power Technology Co., Ltd. (QDTB) in Qingdao, China, designed and tested in accordance with IEEE C57 / ANSI C84.1, vector group Delta-Wye (IEEE Std), short-circuit impedance 6%, approximate weight 3932 kg. Available on FOB Qingdao terms; datasheet, routine test report and GA drawing issued with each unit.

Technical Specifications

SL11-M-1600/10/0.48 technical specifications
ModelSL11-M-1600/10/0.48
Rated Capacity1600kVA
HV Voltage10 kV
LV Voltage0.48 kV
Frequency60 Hz
Vector GroupDelta-Wye (IEEE Std)
Short-circuit Impedance6%
CoolingONAN
InsulationA (105°C)
Temperature Rise65 K
No-load Loss1640 W
Load Loss14500 W
Efficiency1Class 1
Weight3932 kg
Dimensions1436×1230×1773 mm
Applied StandardIEEE C57 / ANSI C84.1

Product Image & Parameters

SL11 - QDTB

Images are for illustration purposes only

SL11-M-1600/10/0.48

SL11 Series

Capacity
1600kVA
HV Voltage
10kV
LV Voltage
0.48kV
Frequency
60Hz
Short-circuit impedance
6%
Cooling method
ONAN
Efficiency
Class 1
Applied standard
IEEE C57 / ANSI C84.1
Connection
Delta-Wye (IEEE Std)
Energy SavingLow Loss

TECHNICAL DRAWING

Model: SL11-M-1600/10/0.48 | Type: Oil-immersed transformer | Capacity: 1600 kVA

FRONT ELEVATION

Oil level1U1V1W2U2V2W2NTAPN.P.270mm330mm

ELECTRICAL SCHEMATIC

HV WINDING (Delta)1U1V1WLV WINDING (Star)2U2V2W2NDelta-Wye (IEEE Std)

EFFICIENCY vs LOAD

90%95%98%99%0%25%50%75%100%≈99%load %efficiency %

SIDE VIEW

Oil level180mm

TOP VIEW

1U1V1W2U2V2W2N180mm

TERMINAL BLOCK

HV TERMINAL BLOCK1U1V1W1N1PELV TERMINAL BLOCK2U2V2W2N2PE2122Terminal block configurationTin-plated copper busbar

CORE & WINDING

OIL / TANKHV winding/bushingINSULATIONLV winding/bushingIron coreconcentric cross-section

Technical specifications

1. Model:SL11-M-1600/10/0.48
2. Type:Oil-immersed transformer
3. Capacity:1600 kVA
4. Frequency:60 Hz
5. HV voltage:10 kV
6. LV voltage:0.48 kV
7. HV current:92.38A
8. LV current:1924.5A
9. Vector group:Delta-Wye (IEEE Std)
10. Impedance:6%
11. Insulation level:A (105°C)
12. Temperature rise:65K
13. No-load loss:1640W
14. Load loss:14500W
15. No-load current:0.3%
16. Cooling method:ONAN
17. Tap changer:±2×2.5% Multi-tap
18. Standard:IEEE C57 / ANSI C84.1
19. Dimensions:1436×1230×1773 mm
20. Weight:3932kg
LEGEND:
Iron core
HV winding/bushing
LV winding/bushing
Dimension line

Product Description

1600kVA, 3-phase oil-immersed transformer, 60Hz, primary 10kV (HV 10kV), secondary 480V (LV 480V), S11, insulation A, impedance 6%

Related Keywords

SL11-M-1600/10/0.48 oil immersed power transformer1600kVA oil type distribution transformer10kV distribution network transformerSL11 aluminum winding oil immersed transformer cost-effective

Instant Selection & Quote Calculator

Select your specifications to get an estimated price instantly.

1 · Configure
More options(6)
Certification
2 · Your price
Derived Ratings (calculated from the configuration)

The values below are computed from what you selected above. Anything that cannot be computed yet is shown as an em dash — never as zero.

Iₙ = S / (√3·U) · I_sc = 100·Iₙ / uₖ · S_sc = √3·U·I_sc · I_p = k·Iₖ

Inputs taken from the configuration
Capacity: — kVAfrom the configuration above
System voltage: not specified
Impedance voltage uₖ: not specified
Result
Rated current Iₙ—
Short-circuit current I_sc—
Short-circuit current I_sc—
Short-circuit power S_sc—
I_sc is calculated on the transformer impedance basis alone (system impedance neglected) — the same basis used in IEC 60076-5 short-circuit calculations.
System voltage → —

Still required to complete the calculation: rated capacity S, impedance voltage uₖ, short-time or peak withstand current.

Per-model values (P0 / Pk / uₖ declared by the factory, losses, noise, temperature rise, dimensions, weight) are not in the product library: those rows stay at an em dash until the factory parameter sheet is supplied. An em dash means the value is unavailable — it is never rendered as zero.

Derived losses (from the selected efficiency grade + capacity)
Class 3 (S13)
No-load loss P0 (kW)—
Load loss Pk (kW)—

Read-only: no price factor, not part of the sum — the loss-grade cost is already carried by the efficiency (subtype) base price, so charging here would double-bill. Values come from the product library type-test data, interpolated between published capacities; grades the library does not cover show an em dash, never zero.

S13 系列(产品库 S13-M / 卷铁芯 S13-M.RL,Class 3)

Reference prices are for estimation only and do not constitute a formal offer.

3 · Get this quote

We will reply with your latest quote instantly.

SL11-M-1600/10/0.48 - Frequently Asked Questions

QWhat are the main applications of SL11-M-1600/10/0.48?

SL11-M-1600/10/0.48 (SL11 series, Oil-Immersed Transformers) is widely used in industrial power distribution, commercial buildings and utility power systems. Can be flexibly configured according to actual project requirements.

QWhat are the main technical specifications of SL11-M-1600/10/0.48?

Key specifications: Capacity: 1600kVA, HV 10 kV, LV 0.48 kV, Frequency 60 Hz, Impedance 6%, Connection Delta-Wye (IEEE Std), Cooling ONAN, Standard IEEE C57 / ANSI C84.1.

QCan SL11-M-1600/10/0.48 be custom ordered?

Yes. QDTB® provides comprehensive OEM/ODM customization services. Parameters such as capacity, voltage ratio, cooling method, connection group and protection class can all be adjusted. Over 25 years of manufacturing experience ensures consistent quality.

QHow to get a quote and technical documentation?

Contact via the "Send Inquiry" button below, or contact sales at Alice@qdtb-transformer.com / +86 13698683193. We provide detailed quotations and technical documentation instantly.

Interested in SL11-M-1600/10/0.48?

Contact us for pricing, technical support, or custom requirements.