QDTB® Transformer

Product Search

Find the right transformer for your needs

ZW20F Series Pole-Mounted Switchgear

1 Models available

ZW20F Pole-Mounted Switchgear

Images are for illustration purposes only

ZW20F Series - Outdoor Vacuum Circuit Breakers with FTU for Distribution Automation

The ZW20F series outdoor vacuum circuit breakers with integrated FTU provide intelligent protection for medium voltage distribution lines. Features factory pre-commissioned plug-and-play design for rapid smart grid deployment.

Model Number Breakdown

20Design series number
ZCircuit breaker (Zhendkong)
WOutdoor type (Wai)
FFTU integrated (Feeder Terminal Unit)

Applications

1

Distribution automation systems

2

Overhead feeder protection

3

Smart grid switching nodes

4

Rural power network modernization

Key Features

  • Vacuum interrupter with integrated FTU terminal
  • Compact outdoor design for pole mounting
  • Factory pre-commissioned for fast installation
  • Supports distribution automation protocols

Specifications Range

All specifications and dimensions can be customized upon request

Key parametersModel Range
HV Voltage (kV)12
Frequency (Hz)50
StandardGB3906, IEC 62271-200
Select 2-3 models to compare
CompareModelCapacity (kVA)HV Voltage (kV)LV Voltage (kV)WeightDimensions
ZW20F-12/630-20—12———

Product Drawing

Electrical Equipment - ZW20F-12/630-20

APPEARANCE
ZW20F-12/630-20

Note: This is a general product illustration. For detailed technical drawings and specifications, please contact our engineering team.

Instant Selection & Quote Calculator

Select your specifications to get an estimated price instantly.

1 · Configure
More options(3)
Certification
2 · Your price
Derived Ratings (calculated from the configuration)

The values below are computed from what you selected above. Anything that cannot be computed yet is shown as an em dash — never as zero.

Iₙ = S / (√3·U) · I_sc = 100·Iₙ / uₖ · S_sc = √3·U·I_sc · I_p = k·Iₖ

Inputs taken from the configuration
System voltage: not specified
Short-time withstand current: not specified
Peak withstand current: not specified
Switchgear system basis: HV switchgear — IEC 62271-1
Frequency: —
Result
Short-time withstand current Iₖ / I_cw—
Peak withstand current I_p / I_pk—
Peak factor k—
System voltage → —

Still required to complete the calculation: rated capacity S, impedance voltage uₖ, short-time or peak withstand current.

Per-model values (P0 / Pk / uₖ declared by the factory, losses, noise, temperature rise, dimensions, weight) are not in the product library: those rows stay at an em dash until the factory parameter sheet is supplied. An em dash means the value is unavailable — it is never rendered as zero.

Reference prices are for estimation only and do not constitute a formal offer.

3 · Get this quote

We will reply with your latest quote instantly.