QDTB® Transformer

CKSC-10/120/12

CKSC Series • 120kVA • 10/10 kV

CKSC-10/120/12 is a 120 kVA, 10/10 kV reactor manufactured by Shandong Yaqing Electric Power Technology Co., Ltd. (QDTB) in Qingdao, China, designed and tested in accordance with GB10229, IEC 60076-6, vector group Series, short-circuit impedance 12%, approximate weight 490 kg. Available on FOB Qingdao terms; datasheet, routine test report and GA drawing issued with each unit.

Technical Specifications

CKSC-10/120/12 technical specifications
ModelCKSC-10/120/12
Rated Capacity120kVA
HV Voltage10 kV
LV Voltage10 kV
Frequency50 Hz
Vector GroupSeries
Short-circuit Impedance12%
CoolingAN
InsulationF (155°C)
Temperature Rise65 K
Weight490 kg
Dimensions570×380×530 mm
Applied StandardGB10229, IEC 60076-6

Product Image & Parameters

CKSC - QDTB

Images are for illustration purposes only

CKSC-10/120/12

CKSC Series

Capacity
120kVA
HV Voltage
10kV
LV Voltage
10kV
Frequency
50Hz
Short-circuit impedance
12%
Cooling method
AN
Applied standard
GB10229, IEC 60076-6
Connection
Series
Insulation class
F (155°C)
Energy SavingLow Loss

Product Drawing

Reactor - CKSC-10/120/12

APPEARANCE — AIR-CORE COIL
REACTORinsulator pedestalCKSC-10/120/12
CONNECTION — SERIES & SHUNT
REACTOR — SERIES & SHUNTSERIES (line)series reactorSHUNT (bus)shunt reactorCKSC-10/120/12
HARMONIC FILTER — LC BRANCH
DETUNED HARMONIC FILTER (LC)reactorcapacitorBUSCKSC-10/120/12

SPECIFICATIONS

1. Model (Product code):CKSC-10/120/12
2. Series:CKSC
3. Rated Capacity:120 kVar
4. Rated voltage:10 kV
5. Rated Current:6.93 A
6. Frequency:50 Hz
7. Reactance factor:12%
8. Temperature Rise:65 K
9. Insulation class:F (155°C)
10. Noise level:≤57 dB(A)
11. Cooling method:AN
12. Connection group:Series
13. Standard:GB10229, IEC 60076-6
14. Weight:490

Note: This is a general product illustration. For detailed technical drawings and specifications, please contact our engineering team.

Product Description

CKSC-10/120/12 medium voltage series reactor. Iron-core construction, F-class insulation, AN cooling. 12% reactance for 10kV power system.

Instant Selection & Quote Calculator

Select your specifications to get an estimated price instantly.

1 · Configure
More options(2)
Reactor Inductance ↔ Rating (mH ↔ kvar)

Fill in any two of inductance L, rated current I and reactive power Q — the third is derived. The phase basis (single / three-phase) must be chosen, because the two bases differ by exactly a factor of three.

X = 2πfL · U_L = I·X · Q₁ = I²X (single-phase) · Q₃ = 3I²X (three-phase)

Inputs
Phase basis (required)
Result
Reactance X = 2πfL—
Inductance L—
Rated current I—
Voltage across the reactor U_L = I·X—
Reactive power, single-phase basis: Q₁ = I²X—
Reactive power, three-phase basis: Q₃ = 3I²Xyour basis—

Still required to complete the calculation: inductance L, rated current I, reactive power Q.

Worked example (the customer case)

L = 1 mH, I = 150 A, f = 50 Hz → X = 0.3142 Ω, U_L = 47.12 V, single-phase Q₁ = 7.07 kvar, three-phase Q₃ = 21.21 kvar.

Single-phase and three-phase differ by exactly a factor of three — always state which basis a kvar figure is quoted on.

Insulation level (IEC 60071-1)
Not specified — the factory parameter sheet is required.
Select a rated voltage in the configuration above to see the matching IEC class.
Non-IEC enquiry case:The enquired Um 15 kV / LI 105 kV / AC 52 kV is not an IEC standard combination (no 15 kV and no 105 kV in IEC lists); it belongs to regional systems such as JEC (Japan) / CNS (Taiwan), where a 15 kV class is about LI 95-110 / AC 50-55. Confirm the system before quoting and map to the nearest IEC class (17.5 kV).

The product library (quote-data) carries no per-model inductance or rated current, so no value is auto-filled for a model; the actual figures are confirmed on the factory parameter sheet. An em dash means the value is unavailable — it is never rendered as zero.

Certification
2 · Your price

Reference prices are for estimation only and do not constitute a formal offer.

3 · Get this quote

We will reply with your latest quote instantly.

CKSC-10/120/12 - Frequently Asked Questions

QWhat are the main applications of CKSC-10/120/12?

CKSC-10/120/12 (CKSC series, Reactors) is widely used in inverter protection, harmonic filtering and power factor improvement. Can be flexibly configured according to actual project requirements.

QWhat are the main technical specifications of CKSC-10/120/12?

Key specifications: Capacity: 120kVA, HV 10 kV, LV 10 kV, Frequency 50 Hz, Impedance 12%, Connection Series, Cooling AN, Standard GB10229, IEC 60076-6.

QHow to get a quote and technical documentation?

Contact via the "Send Inquiry" button below, or contact sales at Alice@qdtb-transformer.com / +86 13698683193. We provide detailed quotations and technical documentation instantly.

Interested in CKSC-10/120/12?

Contact us for pricing, technical support, or custom requirements.