QDTB® Transformer

Product Search

Find the right transformer for your needs

CKSC Series Reactors

232 Models available

CKSC Reactors

Images are for illustration purposes only

CKSC Series - Three-Phase Dry-Type Iron-Core Reactors

The CKSC series represents three-phase dry-type iron-core reactors for power system applications, providing reactive power compensation and current limiting.

Model Number Breakdown

CIron-core construction
KControl application
SThree-phase

Applications

1

Reactive power compensation

2

Current limiting

3

Harmonic filtering

4

Power quality improvement

Key Features

  • Iron-core design for precise reactance
  • Dry-type insulation
  • Low noise operation
  • Reliable performance

Specifications Range

All specifications and dimensions can be customized upon request

Model Selector

Key parametersModel Range
Capacity1–500 kvar
Rated voltage (kV)0.45, 6, 10, 35
Frequency (Hz)50
Impedance (%)6, 7, 12, 14
StandardGB10229, IEC 60076-6
Select 2-3 models to compare
CompareModelSeriesCapacity (kVA)HV Voltage (kV)Current (A)Frequency (Hz)ReactanceTemp. rise (K)InsulationCoolingStandardWeightDimensions
CKSC-0.45/1/6CKSC1kVA0.451.2850665F (155°C)ANGB10229, IEC 60076-620 kg200×150×200 mm
CKSC-0.45/1/7CKSC1kVA0.451.2850765F (155°C)ANGB10229, IEC 60076-620 kg200×150×200 mm
CKSC-0.45/1/12CKSC1kVA0.451.28501265F (155°C)ANGB10229, IEC 60076-620 kg200×150×200 mm
CKSC-0.45/1/14CKSC1kVA0.451.28501465F (155°C)ANGB10229, IEC 60076-620 kg200×150×200 mm
CKSC-0.45/2/6CKSC2kVA0.452.5750665F (155°C)ANGB10229, IEC 60076-630 kg250×180×250 mm
CKSC-0.45/2/7CKSC2kVA0.452.5750765F (155°C)ANGB10229, IEC 60076-630 kg250×180×250 mm
CKSC-0.45/2/12CKSC2kVA0.452.57501265F (155°C)ANGB10229, IEC 60076-630 kg250×180×250 mm
CKSC-0.45/2/14CKSC2kVA0.452.57501465F (155°C)ANGB10229, IEC 60076-630 kg250×180×250 mm
CKSC-0.45/3/6CKSC3kVA0.453.8550665F (155°C)ANGB10229, IEC 60076-640 kg300×200×280 mm
CKSC-0.45/3/7CKSC3kVA0.453.8550765F (155°C)ANGB10229, IEC 60076-640 kg300×200×280 mm
CKSC-0.45/3/12CKSC3kVA0.453.85501265F (155°C)ANGB10229, IEC 60076-640 kg300×200×280 mm
CKSC-0.45/3/14CKSC3kVA0.453.85501465F (155°C)ANGB10229, IEC 60076-640 kg300×200×280 mm
CKSC-0.45/4/6CKSC4kVA0.455.1350665F (155°C)ANGB10229, IEC 60076-650 kg310×210×290 mm
CKSC-0.45/4/7CKSC4kVA0.455.1350765F (155°C)ANGB10229, IEC 60076-650 kg310×210×290 mm
CKSC-0.45/4/12CKSC4kVA0.455.13501265F (155°C)ANGB10229, IEC 60076-650 kg310×210×290 mm
CKSC-0.45/4/14CKSC4kVA0.455.13501465F (155°C)ANGB10229, IEC 60076-650 kg310×210×290 mm
CKSC-0.45/5/6CKSC5kVA0.456.4250665F (155°C)ANGB10229, IEC 60076-655 kg320×220×300 mm
CKSC-0.45/5/7CKSC5kVA0.456.4250765F (155°C)ANGB10229, IEC 60076-655 kg320×220×300 mm
CKSC-0.45/5/12CKSC5kVA0.456.42501265F (155°C)ANGB10229, IEC 60076-655 kg320×220×300 mm
CKSC-0.45/5/14CKSC5kVA0.456.42501465F (155°C)ANGB10229, IEC 60076-655 kg320×220×300 mm
CKSC-0.45/6/6CKSC6kVA0.457.750665F (155°C)ANGB10229, IEC 60076-660 kg330×225×310 mm
CKSC-0.45/6/7CKSC6kVA0.457.750765F (155°C)ANGB10229, IEC 60076-660 kg330×225×310 mm
CKSC-0.45/6/12CKSC6kVA0.457.7501265F (155°C)ANGB10229, IEC 60076-660 kg330×225×310 mm
CKSC-0.45/6/14CKSC6kVA0.457.7501465F (155°C)ANGB10229, IEC 60076-660 kg330×225×310 mm
CKSC-0.45/8/6CKSC8kVA0.4510.2650665F (155°C)ANGB10229, IEC 60076-675 kg355×235×325 mm
CKSC-0.45/8/7CKSC8kVA0.4510.2650765F (155°C)ANGB10229, IEC 60076-675 kg355×235×325 mm
CKSC-0.45/8/12CKSC8kVA0.4510.26501265F (155°C)ANGB10229, IEC 60076-675 kg355×235×325 mm
CKSC-0.45/8/14CKSC8kVA0.4510.26501465F (155°C)ANGB10229, IEC 60076-675 kg355×235×325 mm
CKSC-0.45/10/6CKSC10kVA0.4512.8350665F (155°C)ANGB10229, IEC 60076-685 kg380×250×350 mm
CKSC-0.45/10/7CKSC10kVA0.4512.8350765F (155°C)ANGB10229, IEC 60076-685 kg380×250×350 mm
CKSC-0.45/10/12CKSC10kVA0.4512.83501265F (155°C)ANGB10229, IEC 60076-685 kg380×250×350 mm
CKSC-0.45/10/14CKSC10kVA0.4512.83501465F (155°C)ANGB10229, IEC 60076-685 kg380×250×350 mm
CKSC-0.45/12/6CKSC12kVA0.4515.450665F (155°C)ANGB10229, IEC 60076-695 kg390×260×360 mm
CKSC-0.45/12/7CKSC12kVA0.4515.450765F (155°C)ANGB10229, IEC 60076-695 kg390×260×360 mm
CKSC-0.45/12/12CKSC12kVA0.4515.4501265F (155°C)ANGB10229, IEC 60076-695 kg390×260×360 mm
CKSC-0.45/12/14CKSC12kVA0.4515.4501465F (155°C)ANGB10229, IEC 60076-695 kg390×260×360 mm
CKSC-0.45/15/6CKSC15kVA0.4519.2550665F (155°C)ANGB10229, IEC 60076-6110 kg400×270×380 mm
CKSC-0.45/15/7CKSC15kVA0.4519.2550765F (155°C)ANGB10229, IEC 60076-6110 kg400×270×380 mm
CKSC-0.45/15/12CKSC15kVA0.4519.25501265F (155°C)ANGB10229, IEC 60076-6110 kg400×270×380 mm
CKSC-0.45/15/14CKSC15kVA0.4519.25501465F (155°C)ANGB10229, IEC 60076-6110 kg400×270×380 mm
CKSC-0.45/20/6CKSC20kVA0.4525.6650665F (155°C)ANGB10229, IEC 60076-6140 kg420×280×400 mm
CKSC-0.45/20/7CKSC20kVA0.4525.6650765F (155°C)ANGB10229, IEC 60076-6140 kg420×280×400 mm
CKSC-0.45/20/12CKSC20kVA0.4525.66501265F (155°C)ANGB10229, IEC 60076-6140 kg420×280×400 mm
CKSC-0.45/20/14CKSC20kVA0.4525.66501465F (155°C)ANGB10229, IEC 60076-6140 kg420×280×400 mm
CKSC-0.45/25/6CKSC25kVA0.4532.0850665F (155°C)ANGB10229, IEC 60076-6165 kg435×290×410 mm
CKSC-0.45/25/7CKSC25kVA0.4532.0850765F (155°C)ANGB10229, IEC 60076-6165 kg435×290×410 mm
CKSC-0.45/25/12CKSC25kVA0.4532.08501265F (155°C)ANGB10229, IEC 60076-6165 kg435×290×410 mm
CKSC-0.45/25/14CKSC25kVA0.4532.08501465F (155°C)ANGB10229, IEC 60076-6165 kg435×290×410 mm
CKSC-0.45/30/6CKSC30kVA0.4538.4950665F (155°C)ANGB10229, IEC 60076-6190 kg450×300×420 mm
CKSC-0.45/30/7CKSC30kVA0.4538.4950765F (155°C)ANGB10229, IEC 60076-6190 kg450×300×420 mm
CKSC-0.45/30/12CKSC30kVA0.4538.49501265F (155°C)ANGB10229, IEC 60076-6190 kg450×300×420 mm
CKSC-0.45/30/14CKSC30kVA0.4538.49501465F (155°C)ANGB10229, IEC 60076-6190 kg450×300×420 mm
CKSC-0.45/35/6CKSC35kVA0.4544.9150665F (155°C)ANGB10229, IEC 60076-6210 kg460×305×430 mm
CKSC-0.45/35/7CKSC35kVA0.4544.9150765F (155°C)ANGB10229, IEC 60076-6210 kg460×305×430 mm
CKSC-0.45/35/12CKSC35kVA0.4544.91501265F (155°C)ANGB10229, IEC 60076-6210 kg460×305×430 mm
CKSC-0.45/35/14CKSC35kVA0.4544.91501465F (155°C)ANGB10229, IEC 60076-6210 kg460×305×430 mm
CKSC-0.45/40/6CKSC40kVA0.4551.3250665F (155°C)ANGB10229, IEC 60076-6230 kg465×310×435 mm
CKSC-0.45/40/7CKSC40kVA0.4551.3250765F (155°C)ANGB10229, IEC 60076-6230 kg465×310×435 mm
CKSC-0.45/40/12CKSC40kVA0.4551.32501265F (155°C)ANGB10229, IEC 60076-6230 kg465×310×435 mm
CKSC-0.45/40/14CKSC40kVA0.4551.32501465F (155°C)ANGB10229, IEC 60076-6230 kg465×310×435 mm
CKSC-0.45/50/6CKSC50kVA0.4564.1550665F (155°C)ANGB10229, IEC 60076-6270 kg480×320×450 mm
CKSC-0.45/50/7CKSC50kVA0.4564.1550765F (155°C)ANGB10229, IEC 60076-6270 kg480×320×450 mm
CKSC-0.45/50/12CKSC50kVA0.4564.15501265F (155°C)ANGB10229, IEC 60076-6270 kg480×320×450 mm
CKSC-0.45/50/14CKSC50kVA0.4564.15501465F (155°C)ANGB10229, IEC 60076-6270 kg480×320×450 mm
CKSC-6/10/6CKSC10kVA60.9650665F (155°C)ANGB10229, IEC 60076-685 kg380×250×350 mm
CKSC-6/10/7CKSC10kVA60.9650765F (155°C)ANGB10229, IEC 60076-685 kg380×250×350 mm
CKSC-6/10/12CKSC10kVA60.96501265F (155°C)ANGB10229, IEC 60076-685 kg380×250×350 mm
CKSC-6/10/14CKSC10kVA60.96501465F (155°C)ANGB10229, IEC 60076-685 kg380×250×350 mm
CKSC-6/15/6CKSC15kVA61.4450665F (155°C)ANGB10229, IEC 60076-6110 kg400×270×380 mm
CKSC-6/15/7CKSC15kVA61.4450765F (155°C)ANGB10229, IEC 60076-6110 kg400×270×380 mm
CKSC-6/15/12CKSC15kVA61.44501265F (155°C)ANGB10229, IEC 60076-6110 kg400×270×380 mm
CKSC-6/15/14CKSC15kVA61.44501465F (155°C)ANGB10229, IEC 60076-6110 kg400×270×380 mm
CKSC-6/20/6CKSC20kVA61.9250665F (155°C)ANGB10229, IEC 60076-6140 kg420×280×400 mm
CKSC-6/20/7CKSC20kVA61.9250765F (155°C)ANGB10229, IEC 60076-6140 kg420×280×400 mm
CKSC-6/20/12CKSC20kVA61.92501265F (155°C)ANGB10229, IEC 60076-6140 kg420×280×400 mm
CKSC-6/20/14CKSC20kVA61.92501465F (155°C)ANGB10229, IEC 60076-6140 kg420×280×400 mm
CKSC-6/25/6CKSC25kVA62.4150665F (155°C)ANGB10229, IEC 60076-6165 kg435×290×410 mm
CKSC-6/25/7CKSC25kVA62.4150765F (155°C)ANGB10229, IEC 60076-6165 kg435×290×410 mm
CKSC-6/25/12CKSC25kVA62.41501265F (155°C)ANGB10229, IEC 60076-6165 kg435×290×410 mm
CKSC-6/25/14CKSC25kVA62.41501465F (155°C)ANGB10229, IEC 60076-6165 kg435×290×410 mm
CKSC-6/30/6CKSC30kVA62.8950665F (155°C)ANGB10229, IEC 60076-6190 kg450×300×420 mm
CKSC-6/30/7CKSC30kVA62.8950765F (155°C)ANGB10229, IEC 60076-6190 kg450×300×420 mm
CKSC-6/30/12CKSC30kVA62.89501265F (155°C)ANGB10229, IEC 60076-6190 kg450×300×420 mm
CKSC-6/30/14CKSC30kVA62.89501465F (155°C)ANGB10229, IEC 60076-6190 kg450×300×420 mm
CKSC-6/40/6CKSC40kVA63.8550665F (155°C)ANGB10229, IEC 60076-6230 kg465×310×435 mm
CKSC-6/40/7CKSC40kVA63.8550765F (155°C)ANGB10229, IEC 60076-6230 kg465×310×435 mm
CKSC-6/40/12CKSC40kVA63.85501265F (155°C)ANGB10229, IEC 60076-6230 kg465×310×435 mm
CKSC-6/40/14CKSC40kVA63.85501465F (155°C)ANGB10229, IEC 60076-6230 kg465×310×435 mm
CKSC-6/50/6CKSC50kVA64.8150665F (155°C)ANGB10229, IEC 60076-6270 kg480×320×450 mm
CKSC-6/50/7CKSC50kVA64.8150765F (155°C)ANGB10229, IEC 60076-6270 kg480×320×450 mm
CKSC-6/50/12CKSC50kVA64.81501265F (155°C)ANGB10229, IEC 60076-6270 kg480×320×450 mm
CKSC-6/50/14CKSC50kVA64.81501465F (155°C)ANGB10229, IEC 60076-6270 kg480×320×450 mm
CKSC-6/60/6CKSC60kVA65.7750665F (155°C)ANGB10229, IEC 60076-6305 kg495×330×460 mm
CKSC-6/60/7CKSC60kVA65.7750765F (155°C)ANGB10229, IEC 60076-6305 kg495×330×460 mm
CKSC-6/60/12CKSC60kVA65.77501265F (155°C)ANGB10229, IEC 60076-6305 kg495×330×460 mm
CKSC-6/60/14CKSC60kVA65.77501465F (155°C)ANGB10229, IEC 60076-6305 kg495×330×460 mm
CKSC-6/80/6CKSC80kVA67.750665F (155°C)ANGB10229, IEC 60076-6375 kg525×355×490 mm
CKSC-6/80/7CKSC80kVA67.750765F (155°C)ANGB10229, IEC 60076-6375 kg525×355×490 mm
CKSC-6/80/12CKSC80kVA67.7501265F (155°C)ANGB10229, IEC 60076-6375 kg525×355×490 mm
CKSC-6/80/14CKSC80kVA67.7501465F (155°C)ANGB10229, IEC 60076-6375 kg525×355×490 mm
CKSC-6/100/6CKSC100kVA69.6250665F (155°C)ANGB10229, IEC 60076-6430 kg550×370×520 mm
CKSC-6/100/7CKSC100kVA69.6250765F (155°C)ANGB10229, IEC 60076-6430 kg550×370×520 mm
CKSC-6/100/12CKSC100kVA69.62501265F (155°C)ANGB10229, IEC 60076-6430 kg550×370×520 mm
CKSC-6/100/14CKSC100kVA69.62501465F (155°C)ANGB10229, IEC 60076-6430 kg550×370×520 mm
CKSC-6/120/6CKSC120kVA611.5550665F (155°C)ANGB10229, IEC 60076-6490 kg570×380×530 mm
CKSC-6/120/7CKSC120kVA611.5550765F (155°C)ANGB10229, IEC 60076-6490 kg570×380×530 mm
CKSC-6/120/12CKSC120kVA611.55501265F (155°C)ANGB10229, IEC 60076-6490 kg570×380×530 mm
CKSC-6/120/14CKSC120kVA611.55501465F (155°C)ANGB10229, IEC 60076-6490 kg570×380×530 mm
CKSC-6/150/6CKSC150kVA614.4350665F (155°C)ANGB10229, IEC 60076-6580 kg600×400×550 mm
CKSC-6/150/7CKSC150kVA614.4350765F (155°C)ANGB10229, IEC 60076-6580 kg600×400×550 mm
CKSC-6/150/12CKSC150kVA614.43501265F (155°C)ANGB10229, IEC 60076-6580 kg600×400×550 mm
CKSC-6/150/14CKSC150kVA614.43501465F (155°C)ANGB10229, IEC 60076-6580 kg600×400×550 mm
CKSC-6/200/6CKSC200kVA619.2550665F (155°C)ANGB10229, IEC 60076-6720 kg630×420×580 mm
CKSC-6/200/7CKSC200kVA619.2550765F (155°C)ANGB10229, IEC 60076-6720 kg630×420×580 mm
CKSC-6/200/12CKSC200kVA619.25501265F (155°C)ANGB10229, IEC 60076-6720 kg630×420×580 mm
CKSC-6/200/14CKSC200kVA619.25501465F (155°C)ANGB10229, IEC 60076-6720 kg630×420×580 mm
CKSC-6/250/6CKSC250kVA624.0650665F (155°C)ANGB10229, IEC 60076-6835 kg655×435×600 mm
CKSC-6/250/7CKSC250kVA624.0650765F (155°C)ANGB10229, IEC 60076-6835 kg655×435×600 mm
CKSC-6/250/12CKSC250kVA624.06501265F (155°C)ANGB10229, IEC 60076-6835 kg655×435×600 mm
CKSC-6/250/14CKSC250kVA624.06501465F (155°C)ANGB10229, IEC 60076-6835 kg655×435×600 mm
CKSC-6/300/6CKSC300kVA628.8750665F (155°C)ANGB10229, IEC 60076-6950 kg680×450×620 mm
CKSC-6/300/7CKSC300kVA628.8750765F (155°C)ANGB10229, IEC 60076-6950 kg680×450×620 mm
CKSC-6/300/12CKSC300kVA628.87501265F (155°C)ANGB10229, IEC 60076-6950 kg680×450×620 mm
CKSC-6/300/14CKSC300kVA628.87501465F (155°C)ANGB10229, IEC 60076-6950 kg680×450×620 mm
CKSC-6/400/6CKSC400kVA638.4950665F (155°C)ANGB10229, IEC 60076-61125 kg715×475×650 mm
CKSC-6/400/7CKSC400kVA638.4950765F (155°C)ANGB10229, IEC 60076-61125 kg715×475×650 mm
CKSC-6/400/12CKSC400kVA638.49501265F (155°C)ANGB10229, IEC 60076-61125 kg715×475×650 mm
CKSC-6/400/14CKSC400kVA638.49501465F (155°C)ANGB10229, IEC 60076-61125 kg715×475×650 mm
CKSC-6/500/6CKSC500kVA648.1150665F (155°C)ANGB10229, IEC 60076-61300 kg750×500×680 mm
CKSC-6/500/7CKSC500kVA648.1150765F (155°C)ANGB10229, IEC 60076-61300 kg750×500×680 mm
CKSC-6/500/12CKSC500kVA648.11501265F (155°C)ANGB10229, IEC 60076-61300 kg750×500×680 mm
CKSC-6/500/14CKSC500kVA648.11501465F (155°C)ANGB10229, IEC 60076-61300 kg750×500×680 mm
CKSC-10/10/6CKSC10kVA100.5850665F (155°C)ANGB10229, IEC 60076-685 kg380×250×350 mm
CKSC-10/10/7CKSC10kVA100.5850765F (155°C)ANGB10229, IEC 60076-685 kg380×250×350 mm
CKSC-10/10/12CKSC10kVA100.58501265F (155°C)ANGB10229, IEC 60076-685 kg380×250×350 mm
CKSC-10/10/14CKSC10kVA100.58501465F (155°C)ANGB10229, IEC 60076-685 kg380×250×350 mm
CKSC-10/15/6CKSC15kVA100.8750665F (155°C)ANGB10229, IEC 60076-6110 kg400×270×380 mm
CKSC-10/15/7CKSC15kVA100.8750765F (155°C)ANGB10229, IEC 60076-6110 kg400×270×380 mm
CKSC-10/15/12CKSC15kVA100.87501265F (155°C)ANGB10229, IEC 60076-6110 kg400×270×380 mm
CKSC-10/15/14CKSC15kVA100.87501465F (155°C)ANGB10229, IEC 60076-6110 kg400×270×380 mm
CKSC-10/20/6CKSC20kVA101.1550665F (155°C)ANGB10229, IEC 60076-6140 kg420×280×400 mm
CKSC-10/20/7CKSC20kVA101.1550765F (155°C)ANGB10229, IEC 60076-6140 kg420×280×400 mm
CKSC-10/20/12CKSC20kVA101.15501265F (155°C)ANGB10229, IEC 60076-6140 kg420×280×400 mm
CKSC-10/20/14CKSC20kVA101.15501465F (155°C)ANGB10229, IEC 60076-6140 kg420×280×400 mm
CKSC-10/25/6CKSC25kVA101.4450665F (155°C)ANGB10229, IEC 60076-6165 kg435×290×410 mm
CKSC-10/25/7CKSC25kVA101.4450765F (155°C)ANGB10229, IEC 60076-6165 kg435×290×410 mm
CKSC-10/25/12CKSC25kVA101.44501265F (155°C)ANGB10229, IEC 60076-6165 kg435×290×410 mm
CKSC-10/25/14CKSC25kVA101.44501465F (155°C)ANGB10229, IEC 60076-6165 kg435×290×410 mm
CKSC-10/30/6CKSC30kVA101.7350665F (155°C)ANGB10229, IEC 60076-6190 kg450×300×420 mm
CKSC-10/30/7CKSC30kVA101.7350765F (155°C)ANGB10229, IEC 60076-6190 kg450×300×420 mm
CKSC-10/30/12CKSC30kVA101.73501265F (155°C)ANGB10229, IEC 60076-6190 kg450×300×420 mm
CKSC-10/30/14CKSC30kVA101.73501465F (155°C)ANGB10229, IEC 60076-6190 kg450×300×420 mm
CKSC-10/40/6CKSC40kVA102.3150665F (155°C)ANGB10229, IEC 60076-6230 kg465×310×435 mm
CKSC-10/40/7CKSC40kVA102.3150765F (155°C)ANGB10229, IEC 60076-6230 kg465×310×435 mm
CKSC-10/40/12CKSC40kVA102.31501265F (155°C)ANGB10229, IEC 60076-6230 kg465×310×435 mm
CKSC-10/40/14CKSC40kVA102.31501465F (155°C)ANGB10229, IEC 60076-6230 kg465×310×435 mm
CKSC-10/50/6CKSC50kVA102.8950665F (155°C)ANGB10229, IEC 60076-6270 kg480×320×450 mm
CKSC-10/50/7CKSC50kVA102.8950765F (155°C)ANGB10229, IEC 60076-6270 kg480×320×450 mm
CKSC-10/50/12CKSC50kVA102.89501265F (155°C)ANGB10229, IEC 60076-6270 kg480×320×450 mm
CKSC-10/50/14CKSC50kVA102.89501465F (155°C)ANGB10229, IEC 60076-6270 kg480×320×450 mm
CKSC-10/60/6CKSC60kVA103.4650665F (155°C)ANGB10229, IEC 60076-6305 kg495×330×460 mm
CKSC-10/60/7CKSC60kVA103.4650765F (155°C)ANGB10229, IEC 60076-6305 kg495×330×460 mm
CKSC-10/60/12CKSC60kVA103.46501265F (155°C)ANGB10229, IEC 60076-6305 kg495×330×460 mm
CKSC-10/60/14CKSC60kVA103.46501465F (155°C)ANGB10229, IEC 60076-6305 kg495×330×460 mm
CKSC-10/80/6CKSC80kVA104.6250665F (155°C)ANGB10229, IEC 60076-6375 kg525×355×490 mm
CKSC-10/80/7CKSC80kVA104.6250765F (155°C)ANGB10229, IEC 60076-6375 kg525×355×490 mm
CKSC-10/80/12CKSC80kVA104.62501265F (155°C)ANGB10229, IEC 60076-6375 kg525×355×490 mm
CKSC-10/80/14CKSC80kVA104.62501465F (155°C)ANGB10229, IEC 60076-6375 kg525×355×490 mm
CKSC-10/100/6CKSC100kVA105.7750665F (155°C)ANGB10229, IEC 60076-6430 kg550×370×520 mm
CKSC-10/100/7CKSC100kVA105.7750765F (155°C)ANGB10229, IEC 60076-6430 kg550×370×520 mm
CKSC-10/100/12CKSC100kVA105.77501265F (155°C)ANGB10229, IEC 60076-6430 kg550×370×520 mm
CKSC-10/100/14CKSC100kVA105.77501465F (155°C)ANGB10229, IEC 60076-6430 kg550×370×520 mm
CKSC-10/120/6CKSC120kVA106.9350665F (155°C)ANGB10229, IEC 60076-6490 kg570×380×530 mm
CKSC-10/120/7CKSC120kVA106.9350765F (155°C)ANGB10229, IEC 60076-6490 kg570×380×530 mm
CKSC-10/120/12CKSC120kVA106.93501265F (155°C)ANGB10229, IEC 60076-6490 kg570×380×530 mm
CKSC-10/120/14CKSC120kVA106.93501465F (155°C)ANGB10229, IEC 60076-6490 kg570×380×530 mm
CKSC-10/150/6CKSC150kVA108.6650665F (155°C)ANGB10229, IEC 60076-6580 kg600×400×550 mm
CKSC-10/150/7CKSC150kVA108.6650765F (155°C)ANGB10229, IEC 60076-6580 kg600×400×550 mm
CKSC-10/150/12CKSC150kVA108.66501265F (155°C)ANGB10229, IEC 60076-6580 kg600×400×550 mm
CKSC-10/150/14CKSC150kVA108.66501465F (155°C)ANGB10229, IEC 60076-6580 kg600×400×550 mm
CKSC-10/200/6CKSC200kVA1011.5550665F (155°C)ANGB10229, IEC 60076-6720 kg630×420×580 mm
CKSC-10/200/7CKSC200kVA1011.5550765F (155°C)ANGB10229, IEC 60076-6720 kg630×420×580 mm
CKSC-10/200/12CKSC200kVA1011.55501265F (155°C)ANGB10229, IEC 60076-6720 kg630×420×580 mm
CKSC-10/200/14CKSC200kVA1011.55501465F (155°C)ANGB10229, IEC 60076-6720 kg630×420×580 mm
CKSC-10/250/6CKSC250kVA1014.4350665F (155°C)ANGB10229, IEC 60076-6835 kg655×435×600 mm
CKSC-10/250/7CKSC250kVA1014.4350765F (155°C)ANGB10229, IEC 60076-6835 kg655×435×600 mm
CKSC-10/250/12CKSC250kVA1014.43501265F (155°C)ANGB10229, IEC 60076-6835 kg655×435×600 mm
CKSC-10/250/14CKSC250kVA1014.43501465F (155°C)ANGB10229, IEC 60076-6835 kg655×435×600 mm
CKSC-10/300/6CKSC300kVA1017.3250665F (155°C)ANGB10229, IEC 60076-6950 kg680×450×620 mm
CKSC-10/300/7CKSC300kVA1017.3250765F (155°C)ANGB10229, IEC 60076-6950 kg680×450×620 mm
CKSC-10/300/12CKSC300kVA1017.32501265F (155°C)ANGB10229, IEC 60076-6950 kg680×450×620 mm
CKSC-10/300/14CKSC300kVA1017.32501465F (155°C)ANGB10229, IEC 60076-6950 kg680×450×620 mm
CKSC-10/400/6CKSC400kVA1023.0950665F (155°C)ANGB10229, IEC 60076-61125 kg715×475×650 mm
CKSC-10/400/7CKSC400kVA1023.0950765F (155°C)ANGB10229, IEC 60076-61125 kg715×475×650 mm
CKSC-10/400/12CKSC400kVA1023.09501265F (155°C)ANGB10229, IEC 60076-61125 kg715×475×650 mm
CKSC-10/400/14CKSC400kVA1023.09501465F (155°C)ANGB10229, IEC 60076-61125 kg715×475×650 mm
CKSC-10/500/6CKSC500kVA1028.8750665F (155°C)ANGB10229, IEC 60076-61300 kg750×500×680 mm
CKSC-10/500/7CKSC500kVA1028.8750765F (155°C)ANGB10229, IEC 60076-61300 kg750×500×680 mm
CKSC-10/500/12CKSC500kVA1028.87501265F (155°C)ANGB10229, IEC 60076-61300 kg750×500×680 mm
CKSC-10/500/14CKSC500kVA1028.87501465F (155°C)ANGB10229, IEC 60076-61300 kg750×500×680 mm
CKSC-35/50/6CKSC50kVA350.8250665F (155°C)ANGB10229, IEC 60076-6270 kg480×320×450 mm
CKSC-35/50/7CKSC50kVA350.8250765F (155°C)ANGB10229, IEC 60076-6270 kg480×320×450 mm
CKSC-35/50/12CKSC50kVA350.82501265F (155°C)ANGB10229, IEC 60076-6270 kg480×320×450 mm
CKSC-35/50/14CKSC50kVA350.82501465F (155°C)ANGB10229, IEC 60076-6270 kg480×320×450 mm
CKSC-35/100/6CKSC100kVA351.6550665F (155°C)ANGB10229, IEC 60076-6430 kg550×370×520 mm
CKSC-35/100/7CKSC100kVA351.6550765F (155°C)ANGB10229, IEC 60076-6430 kg550×370×520 mm
CKSC-35/100/12CKSC100kVA351.65501265F (155°C)ANGB10229, IEC 60076-6430 kg550×370×520 mm
CKSC-35/100/14CKSC100kVA351.65501465F (155°C)ANGB10229, IEC 60076-6430 kg550×370×520 mm
CKSC-35/150/6CKSC150kVA352.4750665F (155°C)ANGB10229, IEC 60076-6580 kg600×400×550 mm
CKSC-35/150/7CKSC150kVA352.4750765F (155°C)ANGB10229, IEC 60076-6580 kg600×400×550 mm
CKSC-35/150/12CKSC150kVA352.47501265F (155°C)ANGB10229, IEC 60076-6580 kg600×400×550 mm
CKSC-35/150/14CKSC150kVA352.47501465F (155°C)ANGB10229, IEC 60076-6580 kg600×400×550 mm
CKSC-35/200/6CKSC200kVA353.350665F (155°C)ANGB10229, IEC 60076-6720 kg630×420×580 mm
CKSC-35/200/7CKSC200kVA353.350765F (155°C)ANGB10229, IEC 60076-6720 kg630×420×580 mm
CKSC-35/200/12CKSC200kVA353.3501265F (155°C)ANGB10229, IEC 60076-6720 kg630×420×580 mm
CKSC-35/200/14CKSC200kVA353.3501465F (155°C)ANGB10229, IEC 60076-6720 kg630×420×580 mm
CKSC-35/250/6CKSC250kVA354.1250665F (155°C)ANGB10229, IEC 60076-6835 kg655×435×600 mm
CKSC-35/250/7CKSC250kVA354.1250765F (155°C)ANGB10229, IEC 60076-6835 kg655×435×600 mm
CKSC-35/250/12CKSC250kVA354.12501265F (155°C)ANGB10229, IEC 60076-6835 kg655×435×600 mm
CKSC-35/250/14CKSC250kVA354.12501465F (155°C)ANGB10229, IEC 60076-6835 kg655×435×600 mm
CKSC-35/300/6CKSC300kVA354.9550665F (155°C)ANGB10229, IEC 60076-6950 kg680×450×620 mm
CKSC-35/300/7CKSC300kVA354.9550765F (155°C)ANGB10229, IEC 60076-6950 kg680×450×620 mm
CKSC-35/300/12CKSC300kVA354.95501265F (155°C)ANGB10229, IEC 60076-6950 kg680×450×620 mm
CKSC-35/300/14CKSC300kVA354.95501465F (155°C)ANGB10229, IEC 60076-6950 kg680×450×620 mm
CKSC-35/400/6CKSC400kVA356.650665F (155°C)ANGB10229, IEC 60076-61125 kg715×475×650 mm
CKSC-35/400/7CKSC400kVA356.650765F (155°C)ANGB10229, IEC 60076-61125 kg715×475×650 mm
CKSC-35/400/12CKSC400kVA356.6501265F (155°C)ANGB10229, IEC 60076-61125 kg715×475×650 mm
CKSC-35/400/14CKSC400kVA356.6501465F (155°C)ANGB10229, IEC 60076-61125 kg715×475×650 mm
CKSC-35/500/6CKSC500kVA358.2550665F (155°C)ANGB10229, IEC 60076-61300 kg750×500×680 mm
CKSC-35/500/7CKSC500kVA358.2550765F (155°C)ANGB10229, IEC 60076-61300 kg750×500×680 mm
CKSC-35/500/12CKSC500kVA358.25501265F (155°C)ANGB10229, IEC 60076-61300 kg750×500×680 mm
CKSC-35/500/14CKSC500kVA358.25501465F (155°C)ANGB10229, IEC 60076-61300 kg750×500×680 mm

Product Drawing

Reactor - CKSC-10/50/6

APPEARANCE — AIR-CORE COIL
REACTORinsulator pedestalCKSC-10/50/6
CONNECTION — SERIES & SHUNT
REACTOR — SERIES & SHUNTSERIES (line)series reactorSHUNT (bus)shunt reactorCKSC-10/50/6
HARMONIC FILTER — LC BRANCH
DETUNED HARMONIC FILTER (LC)reactorcapacitorBUSCKSC-10/50/6

Note: This is a general product illustration. For detailed technical drawings and specifications, please contact our engineering team.

Selection Guide

1

Purpose

Series reactor to protect capacitor banks - limits inrush and filters harmonics.

2

Tuning

6% (or 7%) tuning is common for harmonic filtering.

3

Voltage

Match the capacitor bank and network voltage.

- Frequently Asked Questions

What is a series reactor?

A reactor connected in series with capacitor banks to limit inrush and filter harmonics.

Why is CKSC needed?

It protects capacitors from harmonic overload and prevents resonance with the network.

What tuning frequency?

6% (or 7%) tuning is common for harmonic filtering.

Instant Selection & Quote Calculator

Select your specifications to get an estimated price instantly.

1 · Configure
2 · Your price
EXW (FOB Qingdao)
$69
Range $63 ~ $758%)
Price Breakdown
Base price (interpolation)$69
× Product factor×1.0000
× Country factor×1.0000
× Copper-linked factor×1.0000
+ Options / accessories$0
Shipping quoted separately per destination port.

Complete equipment — no winding copper linkage

Reference prices are for estimation only and do not constitute a formal offer.

3 · Get this quote

We will reply with your latest quote instantly.

Related Engineering Calculators

Free sizing and pricing tools for this product category.