QDTB® Transformer

Product Search

Find the right transformer for your needs

KSG-Output Series Reactors

26 Models available

KSG-Output Reactors

Images are for illustration purposes only

KSG-Output Series - Output Reactors for Motor Drive Protection

The KSG-Output series provides three-phase dry-type output reactors fitted between the drive and the motor, filtering harmonic currents and limiting inrush transients. They extend motor cable length capability and protect motor insulation from voltage stress.

Model Number Breakdown

KReactor
SThree-phase
GDry-type
OutputInstalled on the output side of drives

Applications

1

VFD output to motor circuits

2

Long motor cable installations

3

Pump, fan and conveyor drives

4

Harmonic suppression in drive systems

Key Features

  • Harmonic filtering on the drive output
  • Limits inrush current and dv/dt stress
  • Extends allowable motor cable length
  • Class F insulation, low maintenance

Specifications Range

All specifications and dimensions can be customized upon request

Model Selector

Key parametersModel Range
Capacity0.75–400 kvar
Rated current (A)80A, 200A, 150A, 110A, 800A, 50A…
Rated voltage (kV)0.4
Frequency (Hz)50/60
Impedance (%)0.7
StandardGB/T 10228
Select 2-3 models to compare
CompareModelSeriesCapacity (kVA)HV Voltage (kV)Current (A)Frequency (Hz)ReactanceTemp. rise (K)InsulationCoolingStandardWeightDimensions
KSG-Out-KSG-30KWKSG-Output30kVA0.48050/600.765H (180°C)ANGB/T 10228190 kg450×300×420 mm
KSG-Out-KSG-75KWKSG-Output75kVA0.420050/600.765H (180°C)ANGB/T 10228360 kg520×350×480 mm
KSG-Out-KSG-55KWKSG-Output55kVA0.415050/600.765H (180°C)ANGB/T 10228290 kg490×325×455 mm
KSG-Out-KSG-37KWKSG-Output37kVA0.411050/600.765H (180°C)ANGB/T 10228220 kg460×305×430 mm
KSG-Out-KSG-315KWKSG-Output315kVA0.480050/600.765H (180°C)ANGB/T 10228975 kg685×455×625 mm
KSG-Out-KSG-18KWKSG-Output18kVA0.45050/600.765H (180°C)ANGB/T 10228130 kg410×275×390 mm
KSG-Out-KSG-15KWKSG-Output15kVA0.44050/600.765H (180°C)ANGB/T 10228110 kg400×270×380 mm
KSG-Out-KSG-4KWKSG-Output4kVA0.41550/600.765H (180°C)ANGB/T 1022850 kg310×210×290 mm
KSG-Out-KSG-187KWKSG-Output187kVA0.450050/600.765H (180°C)ANGB/T 10228685 kg620×415×570 mm
KSG-Out-KSG-1.5KWKSG-Output1.5kVA0.41050/600.765H (180°C)ANGB/T 1022825 kg225×165×225 mm
KSG-Out-KSG-45KWKSG-Output45kVA0.412550/600.765H (180°C)ANGB/T 10228250 kg470×315×440 mm
KSG-Out-KSG-2.5KWKSG-Output2.5kVA0.41050/600.765H (180°C)ANGB/T 1022835 kg275×190×265 mm
KSG-Out-KSG-93KWKSG-Output93kVA0.425050/600.765H (180°C)ANGB/T 10228410 kg540×365×510 mm
KSG-Out-KSG-160KWKSG-Output160kVA0.445050/600.765H (180°C)ANGB/T 10228610 kg605×405×555 mm
KSG-Out-KSG-110KWKSG-Output110kVA0.427550/600.765H (180°C)ANGB/T 10228460 kg560×375×525 mm
KSG-Out-KSG-5.5KWKSG-Output5.5kVA0.41550/600.765H (180°C)ANGB/T 1022860 kg325×220×305 mm
KSG-Out-KSG-132KWKSG-Output132kVA0.433050/600.765H (180°C)ANGB/T 10228525 kg580×390×540 mm
KSG-Out-KSG-11KWKSG-Output11kVA0.43050/600.765H (180°C)ANGB/T 1022890 kg385×255×355 mm
KSG-Out-KSG-250KWKSG-Output250kVA0.462550/600.765H (180°C)ANGB/T 10228835 kg655×435×600 mm
KSG-Out-KSG-375KWKSG-Output375kVA0.4100050/600.765H (180°C)ANGB/T 102281080 kg705×470×640 mm
KSG-Out-KSG-22KWKSG-Output22kVA0.46050/600.765H (180°C)ANGB/T 10228150 kg425×285×405 mm
KSG-Out-KSG-220KWKSG-Output220kVA0.454050/600.765H (180°C)ANGB/T 10228765 kg640×425×590 mm
KSG-Out-KSG-7.5KWKSG-Output7.5kVA0.42050/600.765H (180°C)ANGB/T 1022870 kg350×230×320 mm
KSG-Out-KSG-200KWKSG-Output200kVA0.451050/600.765H (180°C)ANGB/T 10228720 kg630×420×580 mm
KSG-Out-KSG-0.75KWKSG-Output0.75kVA0.41050/600.765H (180°C)ANGB/T 1022820 kg200×150×200 mm
KSG-Out-KSG-400KWKSG-Output400kVA0.4110050/600.765H (180°C)ANGB/T 102281125 kg715×475×650 mm

Product Drawing

Reactor - KSG-Out-KSG-55KW

APPEARANCE — AIR-CORE COIL
REACTORinsulator pedestalKSG-Out-KSG-55KW
CONNECTION — SERIES & SHUNT
REACTOR — SERIES & SHUNTSERIES (line)series reactorSHUNT (bus)shunt reactorKSG-Out-KSG-55KW
HARMONIC FILTER — LC BRANCH
DETUNED HARMONIC FILTER (LC)reactorcapacitorBUSKSG-Out-KSG-55KW

Note: This is a general product illustration. For detailed technical drawings and specifications, please contact our engineering team.

Instant Selection & Quote Calculator

Select your specifications to get an estimated price instantly.

1 · Configure
More options(2)
Reactor Inductance ↔ Rating (mH ↔ kvar)

Fill in any two of inductance L, rated current I and reactive power Q — the third is derived. The phase basis (single / three-phase) must be chosen, because the two bases differ by exactly a factor of three.

X = 2πfL · U_L = I·X · Q₁ = I²X (single-phase) · Q₃ = 3I²X (three-phase)

Inputs
Phase basis (required)
Result
Reactance X = 2πfL—
Inductance L—
Rated current I—
Voltage across the reactor U_L = I·X—
Reactive power, single-phase basis: Q₁ = I²X—
Reactive power, three-phase basis: Q₃ = 3I²Xyour basis—

Still required to complete the calculation: inductance L, rated current I, reactive power Q.

Worked example (the customer case)

L = 1 mH, I = 150 A, f = 50 Hz → X = 0.3142 Ω, U_L = 47.12 V, single-phase Q₁ = 7.07 kvar, three-phase Q₃ = 21.21 kvar.

Single-phase and three-phase differ by exactly a factor of three — always state which basis a kvar figure is quoted on.

Insulation level (IEC 60071-1)
Not specified — the factory parameter sheet is required.
Select a rated voltage in the configuration above to see the matching IEC class.
Non-IEC enquiry case:The enquired Um 15 kV / LI 105 kV / AC 52 kV is not an IEC standard combination (no 15 kV and no 105 kV in IEC lists); it belongs to regional systems such as JEC (Japan) / CNS (Taiwan), where a 15 kV class is about LI 95-110 / AC 50-55. Confirm the system before quoting and map to the nearest IEC class (17.5 kV).

The product library (quote-data) carries no per-model inductance or rated current, so no value is auto-filled for a model; the actual figures are confirmed on the factory parameter sheet. An em dash means the value is unavailable — it is never rendered as zero.

Certification
2 · Your price

Reference prices are for estimation only and do not constitute a formal offer.

3 · Get this quote

We will reply with your latest quote instantly.

Related Engineering Calculators

Free sizing and pricing tools for this product category.