QDTB® Transformer

KSG-Out-KSG-220KW

KSG-Output Series • 220kVA • 0.4/0.4 kV

KSG-Out-KSG-220KW is a 220 kVA, 0.4/0.4 kV reactor manufactured by Shandong Yaqing Electric Power Technology Co., Ltd. (QDTB) in Qingdao, China, designed and tested in accordance with GB/T 10228, vector group Series, short-circuit impedance 0.7%, approximate weight 765 kg. Available on FOB Qingdao terms; datasheet, routine test report and GA drawing issued with each unit.

Technical Specifications

KSG-Out-KSG-220KW technical specifications
ModelKSG-Out-KSG-220KW
Rated Capacity220kVA
HV Voltage0.4 kV
LV Voltage0.4 kV
Frequency50/60 Hz
Vector GroupSeries
Short-circuit Impedance0.7%
CoolingAN
InsulationH (180°C)
Temperature Rise65 K
Weight765 kg
Dimensions640×425×590 mm
Applied StandardGB/T 10228

Product Image & Parameters

KSG-Output - QDTB

Images are for illustration purposes only

KSG-Out-KSG-220KW

KSG-Output Series

Capacity
220kVA
HV Voltage
0.4kV
LV Voltage
0.4kV
Frequency
50/60Hz
Short-circuit impedance
0.7%
Cooling method
AN
Applied standard
GB/T 10228
Connection
Series
Insulation class
H (180°C)
Energy SavingLow Loss

Product Drawing

Reactor - KSG-Out-KSG-220KW

APPEARANCE — AIR-CORE COIL
REACTORinsulator pedestalKSG-Out-KSG-220KW
CONNECTION — SERIES & SHUNT
REACTOR — SERIES & SHUNTSERIES (line)series reactorSHUNT (bus)shunt reactorKSG-Out-KSG-220KW
HARMONIC FILTER — LC BRANCH
DETUNED HARMONIC FILTER (LC)reactorcapacitorBUSKSG-Out-KSG-220KW

SPECIFICATIONS

1. Model (Product code):KSG-Out-KSG-220KW
2. Series:KSG-Output
3. Rated Capacity:220 kVar
4. Rated voltage:0.4 kV
5. Rated Current:540 A
6. Frequency:50 Hz
7. Reactance factor:0.7%
8. Temperature Rise:65 K
9. Insulation class:H (180°C)
10. Noise level:≤60 dB(A)
11. Cooling method:AN
12. Connection group:Series
13. Standard:GB/T 10228
14. Weight:765

Note: This is a general product illustration. For detailed technical drawings and specifications, please contact our engineering team.

Product Description

KSG-Out KSG-Out-KSG-220KW output reactor for power distribution systems. Capacity 220kVA, voltage 0.4kV. Harmonic filtering and inrush current limiting. Genuine QDTB product.

Instant Selection & Quote Calculator

Select your specifications to get an estimated price instantly.

1 · Configure
More options(2)
Reactor Inductance ↔ Rating (mH ↔ kvar)

Fill in any two of inductance L, rated current I and reactive power Q — the third is derived. The phase basis (single / three-phase) must be chosen, because the two bases differ by exactly a factor of three.

X = 2πfL · U_L = I·X · Q₁ = I²X (single-phase) · Q₃ = 3I²X (three-phase)

Inputs
Phase basis (required)
Result
Reactance X = 2πfL—
Inductance L—
Rated current I—
Voltage across the reactor U_L = I·X—
Reactive power, single-phase basis: Q₁ = I²X—
Reactive power, three-phase basis: Q₃ = 3I²Xyour basis—

Still required to complete the calculation: inductance L, rated current I, reactive power Q.

Worked example (the customer case)

L = 1 mH, I = 150 A, f = 50 Hz → X = 0.3142 Ω, U_L = 47.12 V, single-phase Q₁ = 7.07 kvar, three-phase Q₃ = 21.21 kvar.

Single-phase and three-phase differ by exactly a factor of three — always state which basis a kvar figure is quoted on.

Insulation level (IEC 60071-1)
Not specified — the factory parameter sheet is required.
Select a rated voltage in the configuration above to see the matching IEC class.
Non-IEC enquiry case:The enquired Um 15 kV / LI 105 kV / AC 52 kV is not an IEC standard combination (no 15 kV and no 105 kV in IEC lists); it belongs to regional systems such as JEC (Japan) / CNS (Taiwan), where a 15 kV class is about LI 95-110 / AC 50-55. Confirm the system before quoting and map to the nearest IEC class (17.5 kV).

The product library (quote-data) carries no per-model inductance or rated current, so no value is auto-filled for a model; the actual figures are confirmed on the factory parameter sheet. An em dash means the value is unavailable — it is never rendered as zero.

Certification
2 · Your price

Reference prices are for estimation only and do not constitute a formal offer.

3 · Get this quote

We will reply with your latest quote instantly.

KSG-Out-KSG-220KW - Frequently Asked Questions

QWhat are the main applications of KSG-Out-KSG-220KW?

KSG-Out-KSG-220KW (KSG-Output series, Reactors) is widely used in inverter protection, harmonic filtering and power factor improvement. Can be flexibly configured according to actual project requirements.

QWhat are the main technical specifications of KSG-Out-KSG-220KW?

Key specifications: Capacity: 220kVA, HV 0.4 kV, LV 0.4 kV, Frequency 50/60 Hz, Impedance 0.7%, Connection Series, Cooling AN, Standard GB/T 10228.

QHow to get a quote and technical documentation?

Contact via the "Send Inquiry" button below, or contact sales at Alice@qdtb-transformer.com / +86 13698683193. We provide detailed quotations and technical documentation instantly.

Interested in KSG-Out-KSG-220KW?