BKC-160/10/0.4

BKC Series160 kVA • 10/0.4 kV

Product Image & Parameters

160kVABKC

BKC-160/10/0.4

BKC Series

Capacity
160kVA
HV Voltage
10kV
LV Voltage
0.4kV
Efficiency
2Level
Amorphous Alloy CoreEnergy SavingLow Loss

TECHNICAL DRAWING

Model: BKC-160/10/0.4 | Type: Dry-Type Transformer | Capacity: 160 kVA

FRONT VIEW

HVLV1U1V1W2U2V2W2N150mm210mm

SIDE VIEW

Ventilation120mm

TOP VIEW

1U1V1W2U2V2W2N150mm120mm

TERMINAL BLOCK

HV TERMINAL BLOCK1U1V1W1N1PELV TERMINAL BLOCK2U2V2W2N2PE2122Terminal Block ConfigurationTin-Plated Copper Busbar

ELECTRIC SCHEMATIC DIAGRAM

HV WINDING (Delta)1U1V1WLV WINDING (Star)2U2V2W2NVector GroupDyn11 (IEC)

SPECIFICATIONS

1. Model:BKC-160/10/0.4
2. Type:Dry-Type Transformer
3. Capacity:160 kVA
4. Frequency:50 Hz
5. HV Voltage:10 kV
6. LV Voltage:0.4 kV
7. HV Current:9.24A
8. LV Current:230.94A
9. Vector Group:Dyn11 (IEC)
10. Impedance:6%
11. Insulation Level:H (180°C)
12. Temperature Rise:65K
13. No-Load Loss:5522W
14. Load Loss:13805W
15. No-Load Current:1.2%
16. Cooling Method:AN
17. Tap Changer:±2×2.5% 多档
18. Standard:IEC 60076
19. Dimensions:1000×800×1400mm
20. Weight:-
LEGEND:
Iron Core
HV Winding/Bushing
LV Winding/Bushing
Dimension Line

Product Description

160kVA, 3-phase isolation, dry-type transformer, 50Hz, primary 10kV (HV 10kV), secondary 400V (LV 400V), Standard, insulation H, impedance 6%

Related Keywords

BKC-160/10/0.4 isolation control transformer160kVA control transformerprimary 10kV secondary 0.4kVBKC mining flameproof control transformer for coal mine

BKC-160/10/0.4 FAQ

What are the main application scenarios for BKC-160/10/0.4?
The BKC-160/10/0.4 (BKC series special/isolation/control transformers) with rated capacity of 160 kVA, HV side 10 kV, LV side 0.4 kV, is widely used in industrial distribution, commercial buildings, and power systems. It can be flexibly configured according to actual project requirements.
What are the technical specifications of BKC-160/10/0.4?
Key specs: Capacity 160 kVA, HV 10 kV, LV 0.4 kV, Frequency 50 Hz, Impedance 6%, Vector Group Dyn11 (IEC), Cooling AN, Standard IEC 60076.
Can BKC-160/10/0.4 be customized?
Yes. QDTB® offers comprehensive OEM/ODM customization. Parameters such as capacity, voltage ratio, cooling method, vector group, and protection class can be adjusted. 23+ years of manufacturing experience ensures consistent quality.
How to get a quote and technical documentation?
Contact us via the "Send Inquiry" button below, or reach our sales team at Alice@qdtb-transformer.com / +86 13698683193. We will provide detailed quotations and technical documentation within 24 hours.

Interested in BKC-160/10/0.4?

Contact us for pricing, technical support, or custom requirements.