OZMF Series - Ozone Generator Isolation Transformers

The OZMF series ozone isolation transformers provide high-voltage isolation for ozone generation systems, delivering reliable stepped-up output for dielectric barrier discharge. Dry-type construction with Class F insulation ensures stable ozone generator performance.

Model Number Breakdown

OZOzone
MMedium
FFrequency

Key Features

  • High-voltage output for ozone generation
  • Reliable dielectric barrier discharge supply
  • Class F insulation, dry-type construction
  • Stable performance for continuous operation

Applications

  • Ozone generator power supply
  • Water and air treatment systems
  • Industrial oxidation processes
  • Sanitization equipment

TECHNICAL DRAWING

Model: OZMF-2000W | Type: Oil-immersed transformer | Capacity: 2000 kVA

FRONT ELEVATION

Oil level1U1V1W2U2V2W2NTAPN.P.300mm360mm

ELECTRICAL SCHEMATIC

HV WINDING (Delta)1U1V1WLV WINDING (Star)2U2V2W2NDyn11

EFFICIENCY vs LOAD

90%95%98%99%0%25%50%75%100%≈99%load %efficiency %

SIDE VIEW

Oil level195mm

TOP VIEW

1U1V1W2U2V2W2N195mm

TERMINAL BLOCK

HV TERMINAL BLOCK1U1V1W1N1PELV TERMINAL BLOCK2U2V2W2N2PE2122Terminal block configurationTin-plated copper busbar

CORE & WINDING

OIL / TANKHV winding/bushingINSULATIONLV winding/bushingIron coreconcentric cross-section
LEGEND:
Iron core
HV winding/bushing
LV winding/bushing
Dimension line

Specifications Range

All specifications and dimensions can be customized upon request

Model Selector

Key parametersModel Range
Capacity500–5000 kVA
HV Voltage (kV)0.38
LV Voltage (kV)50.5, 5.5, 10.5, 20.5, 30.5
Frequency (Hz)400-1000
Impedance (%)6
CoolingAN
StandardGB/T 1094, IEC 60076
Select 2-3 models to compare
CompareModelSeriesCapacity (kVA)HV Voltage (kV)LV Voltage (kV)Frequency (Hz)ReactanceCoolingStandardWeightDimensions
OZMF-5000WOzone-MF5000kVA0.3850.5400-10006ANGB/T 1094, IEC 600769000 kg1700×1400×1700 mm
OZMF-500WOzone-MF500kVA0.385.5400-10006ANGB/T 1094, IEC 600761300 kg850×700×850 mm
OZMF-1000WOzone-MF1000kVA0.3810.5400-10006ANGB/T 1094, IEC 600762300 kg1050×880×1100 mm
OZMF-2000WOzone-MF2000kVA0.3820.5400-10006ANGB/T 1094, IEC 600764100 kg1300×1050×1300 mm
OZMF-3000WOzone-MF3000kVA0.3830.5400-10006ANGB/T 1094, IEC 600765845 kg1475×1175×1475 mm

Instant Selection & Quote Calculator

Select your specifications to get an estimated price instantly.

1 · Configure
More options(2)
Certification
2 · Your price
Derived Ratings (calculated from the configuration)

The values below are computed from what you selected above. Anything that cannot be computed yet is shown as an em dash — never as zero.

Iₙ = S / (√3·U) · I_sc = 100·Iₙ / uₖ · S_sc = √3·U·I_sc · I_p = k·Iₖ

Inputs taken from the configuration
Capacity: — kVAfrom the configuration above
System voltage: not specified
Impedance voltage uₖ: not specified
Result
Rated current Iₙ—
Short-circuit current I_sc—
Short-circuit current I_sc—
Short-circuit power S_sc—
I_sc is calculated on the transformer impedance basis alone (system impedance neglected) — the same basis used in IEC 60076-5 short-circuit calculations.

Still required to complete the calculation: rated capacity S, impedance voltage uₖ, short-time or peak withstand current.

Per-model values (P0 / Pk / uₖ declared by the factory, losses, noise, temperature rise, dimensions, weight) are not in the product library: those rows stay at an em dash until the factory parameter sheet is supplied. An em dash means the value is unavailable — it is never rendered as zero.

Derived losses (from the selected efficiency grade + capacity)
No-load loss P0 (kW)—
Load loss Pk (kW)—

Read-only: no price factor, not part of the sum — the loss-grade cost is already carried by the efficiency (subtype) base price, so charging here would double-bill. Values come from the product library type-test data, interpolated between published capacities; grades the library does not cover show an em dash, never zero.

特种/隔离/控制变压器(产品库逐型号 noLoadLoss,无独立能效档维度)

Reference prices are for estimation only and do not constitute a formal offer.

3 · Get this quote

We will reply with your latest quote instantly.

Related Engineering Calculators

Free sizing and pricing tools for this product category.