OZMF-1000W is a 1000 kVA, 0.38/10.5 kV special/isolation/control transformer manufactured by Shandong Yaqing Electric Power Technology Co., Ltd. (QDTB) in Qingdao, China, designed and tested in accordance with GB/T 1094, IEC 60076, short-circuit impedance 6%, approximate weight 2300 kg. Available on FOB Qingdao terms; datasheet, routine test report and GA drawing issued with each unit.

Technical Specifications

OZMF-1000W technical specifications
ModelOZMF-1000W
Rated Capacity1000kVA
HV Voltage0.38 kV
LV Voltage10.5 kV
Input Voltage220V/380V
Output VoltageMedium frequency high voltage
Frequency400-1000 Hz
Short-circuit Impedance6%
CoolingAN
Weight2300 kg
Dimensions1050×880×1100 mm
Applied StandardGB/T 1094, IEC 60076

Product Image & Parameters

Ozone-MF - QDTB

Images are for illustration purposes only

OZMF-1000W

Ozone-MF Series

Capacity
1000kVA
Frequency
400-1000Hz
Short-circuit impedance
6%
Cooling method
AN
Applied standard
GB/T 1094, IEC 60076
Dimensions
1050×880×1100 mm
Weight
2300kg
Energy SavingLow Loss

TECHNICAL DRAWING

Model: OZMF-1000W | Type: Oil-immersed transformer | Capacity: 1000 kVA

FRONT ELEVATION

Oil level1U1V1W2U2V2W2NTAPN.P.240mm300mm

ELECTRICAL SCHEMATIC

HV WINDING (Delta)1U1V1WLV WINDING (Star)2U2V2W2NDyn11

EFFICIENCY vs LOAD

90%95%98%99%0%25%50%75%100%≈99%load %efficiency %

SIDE VIEW

Oil level165mm

TOP VIEW

1U1V1W2U2V2W2N165mm

TERMINAL BLOCK

HV TERMINAL BLOCK1U1V1W1N1PELV TERMINAL BLOCK2U2V2W2N2PE2122Terminal block configurationTin-plated copper busbar

CORE & WINDING

OIL / TANKHV winding/bushingINSULATIONLV winding/bushingIron coreconcentric cross-section

Technical specifications

1. Model:OZMF-1000W
2. Type:Oil-immersed transformer
3. Capacity:1000 kVA
4. Frequency:50 Hz
5. HV voltage:0.38 kV
6. LV voltage:10.5 kV
7. HV current:-
8. LV current:-
9. Vector group:Dyn11
10. Impedance:6%
11. Insulation level:A
12. Temperature rise:65K
13. No-load loss:-
14. Load loss:-
15. No-load current:-
16. Cooling method:AN
17. Tap changer:±2×2.5%
18. Standard:GB/T 1094, IEC 60076
19. Dimensions:1050×880×1100 mm
20. Weight:2300kg
LEGEND:
Iron core
HV winding/bushing
LV winding/bushing
Dimension line

Product Description

OZMF-1000W series Ozone-MF Ozone isolation transformer. 1000kVA 0.38kV/10.5kV. Class F insulation, dry-type design. Genuine QDTB product, ISO 9001 certified, global export.

Instant Selection & Quote Calculator

Select your specifications to get an estimated price instantly.

1 · Configure
More options(2)
Certification
2 · Your price
Derived Ratings (calculated from the configuration)

The values below are computed from what you selected above. Anything that cannot be computed yet is shown as an em dash — never as zero.

Iₙ = S / (√3·U) · I_sc = 100·Iₙ / uₖ · S_sc = √3·U·I_sc · I_p = k·Iₖ

Inputs taken from the configuration
Capacity: — kVAfrom the configuration above
System voltage: not specified
Impedance voltage uₖ: not specified
Result
Rated current Iₙ—
Short-circuit current I_sc—
Short-circuit current I_sc—
Short-circuit power S_sc—
I_sc is calculated on the transformer impedance basis alone (system impedance neglected) — the same basis used in IEC 60076-5 short-circuit calculations.

Still required to complete the calculation: rated capacity S, impedance voltage uₖ, short-time or peak withstand current.

Per-model values (P0 / Pk / uₖ declared by the factory, losses, noise, temperature rise, dimensions, weight) are not in the product library: those rows stay at an em dash until the factory parameter sheet is supplied. An em dash means the value is unavailable — it is never rendered as zero.

Derived losses (from the selected efficiency grade + capacity)
No-load loss P0 (kW)—
Load loss Pk (kW)—

Read-only: no price factor, not part of the sum — the loss-grade cost is already carried by the efficiency (subtype) base price, so charging here would double-bill. Values come from the product library type-test data, interpolated between published capacities; grades the library does not cover show an em dash, never zero.

特种/隔离/控制变压器(产品库逐型号 noLoadLoss,无独立能效档维度)

Reference prices are for estimation only and do not constitute a formal offer.

3 · Get this quote

We will reply with your latest quote instantly.

OZMF-1000W - Frequently Asked Questions

QWhat are the main applications of OZMF-1000W?

OZMF-1000W (Ozone-MF series, Special/Isolation/Control Transformers) is widely used in industrial power distribution, commercial buildings and utility power systems. Can be flexibly configured according to actual project requirements.

QWhat are the main technical specifications of OZMF-1000W?

Key specifications: Capacity: 1000kVA, HV 0.38 kV, LV 10.5 kV, Frequency 400-1000 Hz, Impedance 6%, Cooling AN, Standard GB/T 1094, IEC 60076.

QCan OZMF-1000W be custom ordered?

Yes. QDTB® provides comprehensive OEM/ODM customization services. Parameters such as capacity, voltage ratio, cooling method, connection group and protection class can all be adjusted. Over 25 years of manufacturing experience ensures consistent quality.

QHow to get a quote and technical documentation?

Contact via the "Send Inquiry" button below, or contact sales at Alice@qdtb-transformer.com / +86 13698683193. We provide detailed quotations and technical documentation instantly.

Interested in OZMF-1000W?

Contact us for pricing, technical support, or custom requirements.