Oil-Immersed Isolation Transformers Series Three Phase Transformers

11 Models available

Oil-Immersed Isolation Transformers Three Phase Transformers

Images are for illustration purposes only

Oil-Immersed Isolation Transformers — Three Phase Rectifier Duty

Oil-immersed three-phase isolation and rectifier transformers provide galvanic isolation between the supply and load with oil-immersed cooling for higher ratings and outdoor duty. Rated 10–2500 kVA, 6/10/35 kV primary, for rectifier, isolation and power-conversion applications requiring robust oil-immersed construction.

Key Features

  • Galvanic isolation between primary and secondary
  • Oil-immersed ONAN cooling for higher ratings
  • 10–2500 kVA, 6/10/35 kV primary
  • Suitable for outdoor and rectifier duty
  • Sealed tank with conservator or sealed design
  • Custom impedance and vector groups

Applications

  • Rectifier and power-conversion systems
  • Industrial isolation and grounding
  • Outdoor distribution isolation
  • Renewable plant auxiliary supplies

TECHNICAL DRAWING

Model: ISO-200KVA | Type: Oil-immersed transformer | Capacity: 200 kVA

FRONT ELEVATION

Oil level1U1V1W2U2V2W2NTAPN.P.150mm210mm

ELECTRICAL SCHEMATIC

HV WINDING (Delta)1U1V1WLV WINDING (Star)2U2V2W2NDyn11

EFFICIENCY vs LOAD

90%95%98%99%0%25%50%75%100%≈99%load %efficiency %

SIDE VIEW

Oil level120mm

TOP VIEW

1U1V1W2U2V2W2N120mm

TERMINAL BLOCK

HV TERMINAL BLOCK1U1V1W1N1PELV TERMINAL BLOCK2U2V2W2N2PE2122Terminal block configurationTin-plated copper busbar

CORE & WINDING

OIL / TANKHV winding/bushingINSULATIONLV winding/bushingIron coreconcentric cross-section
LEGEND:
Iron core
HV winding/bushing
LV winding/bushing
Dimension line

Specifications Range

All specifications and dimensions can be customized upon request

Model Selector

Key parametersModel Range
Capacity50–630 kVA
HV Voltage (kV)10
LV Voltage (kV)0.4
Frequency (Hz)50/60
Impedance (%)4.5
CoolingONAN
Efficiency>97%
StandardIEC 60076 / GB1094.1
ConnectionDyn11
Insulation classA(105°C)
Allowed temperature rise65
Noise level50 dB(A), 55 dB(A), 58 dB(A), 61 dB(A), 64 dB(A)
Tap Changer±5%
No-load loss130–810 W
Load loss870–6200 W
Select 2-3 models to compare
CompareModelSeriesCapacity (kVA)Input voltageOutput voltageFrequency (Hz)Rated current (A)WeightDimensions
ISO-50KVAOil-Immersed Isolation Transformers50kVA10kV (3-phase)0.4kV isolated secondary50/60—275 kg1180×920×1575 mm
ISO-80KVAOil-Immersed Isolation Transformers80kVA10kV (3-phase)0.4kV isolated secondary50/60—336 kg1280×995×1705 mm
ISO-100KVAOil-Immersed Isolation Transformers100kVA10kV (3-phase)0.4kV isolated secondary50/60—375 kg1335×1040×1780 mm
ISO-125KVAOil-Immersed Isolation Transformers125kVA10kV (3-phase)0.4kV isolated secondary50/60—422 kg1400×1090×1870 mm
ISO-160KVAOil-Immersed Isolation Transformers160kVA10kV (3-phase)0.4kV isolated secondary50/60—486 kg1485×1155×1980 mm
ISO-200KVAOil-Immersed Isolation Transformers200kVA10kV (3-phase)0.4kV isolated secondary50/60—556 kg1570×1220×2095 mm
ISO-250KVAOil-Immersed Isolation Transformers250kVA10kV (3-phase)0.4kV isolated secondary50/60—641 kg1670×1300×2230 mm
ISO-315KVAOil-Immersed Isolation Transformers315kVA10kV (3-phase)0.4kV isolated secondary50/60—748 kg1790×1390×2385 mm
ISO-400KVAOil-Immersed Isolation Transformers400kVA10kV (3-phase)0.4kV isolated secondary50/60—882 kg1930×1500×2575 mm
ISO-500KVAOil-Immersed Isolation Transformers500kVA10kV (3-phase)0.4kV isolated secondary50/60—1035 kg2085×1620×2780 mm
ISO-630KVAOil-Immersed Isolation Transformers630kVA10kV (3-phase)0.4kV isolated secondary50/60—1228 kg2270×1765×3025 mm

Selection Guide

1

Cooling

Confirm ONAN oil-immersed cooling for the rating and environment.

2

Isolation

Specify the required isolation level and vector group.

- Frequently Asked Questions

Why choose oil-immersed isolation?

Oil-immersed construction supports higher ratings and outdoor installation, with the transformer providing galvanic isolation to decouple the load from supply-side faults and noise.

What ratings are available?

10–2500 kVA at 6/10/35 kV, sized to the isolation or rectifier duty.

Instant Selection & Quote Calculator

Select your specifications to get an estimated price instantly.

1 · Configure
More options(2)
Certification
2 · Your price
Derived Ratings (calculated from the configuration)

The values below are computed from what you selected above. Anything that cannot be computed yet is shown as an em dash — never as zero.

Iₙ = S / (√3·U) · I_sc = 100·Iₙ / uₖ · S_sc = √3·U·I_sc · I_p = k·Iₖ

Inputs taken from the configuration
Capacity: — kVAfrom the configuration above
System voltage: not specified
Impedance voltage uₖ: not specified
Result
Rated current Iₙ—
Short-circuit current I_sc—
Short-circuit current I_sc—
Short-circuit power S_sc—
I_sc is calculated on the transformer impedance basis alone (system impedance neglected) — the same basis used in IEC 60076-5 short-circuit calculations.

Still required to complete the calculation: rated capacity S, impedance voltage uₖ, short-time or peak withstand current.

Per-model values (P0 / Pk / uₖ declared by the factory, losses, noise, temperature rise, dimensions, weight) are not in the product library: those rows stay at an em dash until the factory parameter sheet is supplied. An em dash means the value is unavailable — it is never rendered as zero.

Derived losses (from the selected efficiency grade + capacity)
No-load loss P0 (kW)—
Load loss Pk (kW)—

Read-only: no price factor, not part of the sum — the loss-grade cost is already carried by the efficiency (subtype) base price, so charging here would double-bill. Values come from the product library type-test data, interpolated between published capacities; grades the library does not cover show an em dash, never zero.

Reference prices are for estimation only and do not constitute a formal offer.