QDTB® Transformer

ISO-500KVA

Oil-Immersed Isolation Transformers Series • 500kVA • 10/0.4 kV

ISO-500KVA is a 500 kVA, 10/0.4 kV three phase transformer manufactured by Shandong Yaqing Electric Power Technology Co., Ltd. (QDTB) in Qingdao, China, designed and tested in accordance with IEC 60076 / GB1094.1, vector group Dyn11, short-circuit impedance 4.5%, approximate weight 1035 kg. Available on FOB Qingdao terms; datasheet, routine test report and GA drawing issued with each unit.

Technical Specifications

ISO-500KVA technical specifications
ModelISO-500KVA
Rated Capacity500kVA
HV Voltage10 kV
LV Voltage0.4 kV
Input Voltage10kV (3-phase)
Output Voltage0.4kV isolated secondary
Frequency50/60 Hz
Vector GroupDyn11
Short-circuit Impedance4.5%
CoolingONAN
InsulationA(105°C)
Temperature Rise65 K
No-load Loss680 W
Load Loss5100 W
Efficiency>97%
Weight1035 kg
Dimensions (L x W x H)2085 x 1620 x 2780 mm
Applied StandardIEC 60076 / GB1094.1

Typical operating points

Calculated from this model’s nameplate losses (P₀ 680 W, P_k 5100 W), u_k 4.5%, at power factor 0.9.

LoadOutput (kW)No-load loss (kW)Load loss (kW)Total loss (kW)Efficiency (%)Voltage regulation (%)
50%225.00.6801.2751.95599.141.43
75%337.50.6802.8693.54998.962.16
100%450.00.6805.1005.78098.732.89
125%562.50.6807.9698.64998.493.63

Highest efficiency around 183 kVA (36.5% of rating) — β* = √(P₀ / P_k).

Product Image & Parameters

Oil-Immersed Isolation Transformers - QDTB

Images are for illustration purposes only

ISO-500KVA

Oil-Immersed Isolation Transformers Series

Capacity
500kVA
Frequency
50/60Hz
Short-circuit impedance
4.5%
Cooling method
ONAN
Efficiency
>97%
Applied standard
IEC 60076 / GB1094.1
Connection
Dyn11
Insulation class
A(105°C)
Allowed temperature rise
65K
Dry TypeFire SafeHigh Efficiency

TECHNICAL DRAWING

Model: ISO-500KVA | Type: Oil-immersed transformer | Capacity: 500 kVA

FRONT ELEVATION

Oil level1U1V1W2U2V2W2NTAPN.P.210mm270mm

ELECTRICAL SCHEMATIC

HV WINDING (Delta)1U1V1WLV WINDING (Star)2U2V2W2NDyn11

EFFICIENCY vs LOAD

90%95%98%99%0%25%50%75%100%≈99%load %efficiency %

SIDE VIEW

Oil level150mm

TOP VIEW

1U1V1W2U2V2W2N150mm

TERMINAL BLOCK

HV TERMINAL BLOCK1U1V1W1N1PELV TERMINAL BLOCK2U2V2W2N2PE2122Terminal block configurationTin-plated copper busbar

CORE & WINDING

OIL / TANKHV winding/bushingINSULATIONLV winding/bushingIron coreconcentric cross-section

Technical specifications

1. Model:ISO-500KVA
2. Type:Oil-immersed transformer
3. Capacity:500 kVA
4. Frequency:50 Hz
5. HV voltage:10 kV
6. LV voltage:0.4 kV
7. HV current:-
8. LV current:-
9. Vector group:Dyn11
10. Impedance:4.5%
11. Insulation level:A(105°C)
12. Temperature rise:65K
13. No-load loss:680W
14. Load loss:5100W
15. No-load current:-
16. Cooling method:ONAN
17. Tap changer:±5%
18. Standard:IEC 60076 / GB1094.1
19. Dimensions:1400×1000×1800mm
20. Weight:1035kg
LEGEND:
Iron core
HV winding/bushing
LV winding/bushing
Dimension line

Product Description

ISO-500KVA Oil-Immersed Isolation Transformers Oil-immersed Isolation Transformer, rated 500kVA, input 10kV (3-phase), output 0.4kV isolated secondary, eff >97%, freq 50/60, weight 1035kg, ISO certified China manufacturer

Related Keywords

ISO-500KVAOil-Immersedoil-immersed isolation transformer500kVA

Instant Selection & Quote Calculator

Select your specifications to get an estimated price instantly.

1 · Configure
More options(2)
Certification
2 · Your price
Derived Ratings (calculated from the configuration)

The values below are computed from what you selected above. Anything that cannot be computed yet is shown as an em dash — never as zero.

Iₙ = S / (√3·U) · I_sc = 100·Iₙ / uₖ · S_sc = √3·U·I_sc · I_p = k·Iₖ

Inputs taken from the configuration
Capacity: — kVAfrom the configuration above
System voltage: not specified
Impedance voltage uₖ: not specified
Result
Rated current Iₙ—
Short-circuit current I_sc—
Short-circuit current I_sc—
Short-circuit power S_sc—
I_sc is calculated on the transformer impedance basis alone (system impedance neglected) — the same basis used in IEC 60076-5 short-circuit calculations.

Still required to complete the calculation: rated capacity S, impedance voltage uₖ, short-time or peak withstand current.

Per-model values (P0 / Pk / uₖ declared by the factory, losses, noise, temperature rise, dimensions, weight) are not in the product library: those rows stay at an em dash until the factory parameter sheet is supplied. An em dash means the value is unavailable — it is never rendered as zero.

Derived losses (from the selected efficiency grade + capacity)
No-load loss P0 (kW)—
Load loss Pk (kW)—

Read-only: no price factor, not part of the sum — the loss-grade cost is already carried by the efficiency (subtype) base price, so charging here would double-bill. Values come from the product library type-test data, interpolated between published capacities; grades the library does not cover show an em dash, never zero.

Reference prices are for estimation only and do not constitute a formal offer.

3 · Get this quote

We will reply with your latest quote instantly.

ISO-500KVA - Frequently Asked Questions

QWhat are the main applications of ISO-500KVA?

ISO-500KVA (Oil-Immersed Isolation Transformers series, Three Phase Transformers) is widely used in industrial power distribution, commercial buildings and utility power systems. Can be flexibly configured according to actual project requirements.

QWhat are the main technical specifications of ISO-500KVA?

Key specifications: Capacity: 500kVA, HV 10 kV, LV 0.4 kV, Frequency 50/60 Hz, Impedance 4.5%, Connection Dyn11, Cooling ONAN, Standard IEC 60076 / GB1094.1.

QCan ISO-500KVA be custom ordered?

Yes. QDTB® provides comprehensive OEM/ODM customization services. Parameters such as capacity, voltage ratio, cooling method, connection group and protection class can all be adjusted. Over 25 years of manufacturing experience ensures consistent quality.

QHow to get a quote and technical documentation?

Contact via the "Send Inquiry" button below, or contact sales at Alice@qdtb-transformer.com / +86 13698683193. We provide detailed quotations and technical documentation instantly.

Interested in ISO-500KVA?

Contact us for pricing, technical support, or custom requirements.