EPS Emergency Power Supply Series UPS (Uninterruptible Power Supply)
15 Models available

Images are for illustration purposes only
EPS Emergency Power Supply — Fire Emergency Inverter Systems
EPS (Emergency Power Supply) systems provide automatic AC backup power for fire protection and emergency loads during a mains failure, using inverter technology with a battery bank and automatic transfer. Available in lighting-type (for emergency lighting and evacuation signs) and power-type (for fire pumps, smoke exhaust fans, and elevators) configurations from 1 to 500 kW, single-phase 220V and three-phase 380V output.
Key Features
Automatic transfer to battery inverter within seconds of mains loss
Lighting-type and power-type (motor load) configurations
Three-phase 380V and single-phase 220V output options
Pure sine wave output compatible with fire pumps and emergency fans
Battery bank sized for 90-minute fire protection duty
Wall-mount and floor-standing enclosures with status monitoring
Applications
- Fire emergency lighting and evacuation signs
- Fire pumps and smoke exhaust fans
- Elevators and life-safety loads
- Commercial buildings, tunnels and industrial sites
Specifications Range
All specifications and dimensions can be customized upon request
Model Selector
| Key parameters | Model Range |
|---|---|
| Capacity | 0.5–100 VA |
| Input voltage | 380/220VAC ±15% |
| Output voltage | 380/220VAC |
| Transfer Time | <0.1s (grid fail) |
| Frequency (Hz) | 50/60 |
| Efficiency | >92% |
| Compare | Model | Series | Capacity (kVA) | Input voltage | Frequency (Hz) | Weight | Weight | Dimensions |
|---|---|---|---|---|---|---|---|---|
| EPS-0.5KW | EPS Emergency Power Supply | 0.5kW | 380/220VAC ±15% | 50/60 | 33 | 33 kg | 610×505×1220 mm | |
| EPS-1KW | EPS Emergency Power Supply | 1kW | 380/220VAC ±15% | 50/60 | 36 | 36 kg | 615×510×1230 mm | |
| EPS-1.5KW | EPS Emergency Power Supply | 1.5kW | 380/220VAC ±15% | 50/60 | 39 | 39 kg | 620×515×1240 mm | |
| EPS-2KW | EPS Emergency Power Supply | 2kW | 380/220VAC ±15% | 50/60 | 41 | 41 kg | 625×520×1250 mm | |
| EPS-3KW | EPS Emergency Power Supply | 3kW | 380/220VAC ±15% | 50/60 | 46 | 46 kg | 630×525×1265 mm | |
| EPS-5KW | EPS Emergency Power Supply | 5kW | 380/220VAC ±15% | 50/60 | 55 | 55 kg | 645×535×1290 mm | |
| EPS-7.5KW | EPS Emergency Power Supply | 7.5kW | 380/220VAC ±15% | 50/60 | 66 | 66 kg | 655×545×1315 mm | |
| EPS-10KW | EPS Emergency Power Supply | 10kW | 380/220VAC ±15% | 50/60 | 76 | 76 kg | 670×555×1340 mm | |
| EPS-15KW | EPS Emergency Power Supply | 15kW | 380/220VAC ±15% | 50/60 | 94 | 94 kg | 690×575×1380 mm | |
| EPS-20KW | EPS Emergency Power Supply | 20kW | 380/220VAC ±15% | 50/60 | 112 | 112 kg | 705×585×1415 mm | |
| EPS-30KW | EPS Emergency Power Supply | 30kW | 380/220VAC ±15% | 50/60 | 147 | 147 kg | 735×615×1475 mm | |
| EPS-45KW | EPS Emergency Power Supply | 45kW | 380/220VAC ±15% | 50/60 | 195 | 195 kg | 775×645×1555 mm | |
| EPS-60KW | EPS Emergency Power Supply | 60kW | 380/220VAC ±15% | 50/60 | 241 | 241 kg | 810×675×1625 mm | |
| EPS-80KW | EPS Emergency Power Supply | 80kW | 380/220VAC ±15% | 50/60 | 299 | 299 kg | 850×710×1705 mm | |
| EPS-100KW | EPS Emergency Power Supply | 100kW | 380/220VAC ±15% | 50/60 | 355 | 355 kg | 890×740×1780 mm |
Product Drawing
Electrical Equipment - EPS-10KW
Note: This is a general product illustration. For detailed technical drawings and specifications, please contact our engineering team.
Selection Guide
Load type
Choose lighting-type for luminaires and signs, power-type for motors and pumps.
Battery autonomy
Specify 90 minutes or longer per local fire-code requirements.
Phase
Match single-phase 220V or three-phase 380V to the connected loads.
- Frequently Asked Questions
What is the difference between EPS and UPS?
An EPS supplies fire protection and emergency loads only during an outage and may start in standby (off-line) mode, while a UPS continuously conditions power for sensitive electronic loads with zero transfer time. EPS is normally sized for 90-minute fire duty and motor loads.
What loads can an EPS drive?
Lighting-type EPS drives emergency lighting; power-type EPS drives inductive loads such as fire pumps, smoke fans and elevators, sized for motor starting current.
How long must an EPS run on battery?
Fire codes commonly require at least 90 minutes of battery autonomy for emergency lighting and fire equipment.
Instant Selection & Quote Calculator
Select your specifications to get an estimated price instantly.