Distribution Transformer Selection & Price Guide 2026
Standard S13-M oil-immersed and SCB13 dry-type distribution transformers — full model numbers linked to product pages, with descriptions and live copper-adjusted FOB Qingdao reference prices driven by the pricing engine.
Oil-Immersed Distribution Transformers — S13-M
Three-phase, S13 low-loss, 10 kV / 0.4 kV, copper winding, off-load tap changer, Dyn11. Standard-design models below map one-to-one to live product pages. FOB Qingdao reference prices are copper-adjusted.
| Capacity | Model | Description | Reference price (FOB) |
|---|---|---|---|
| 100 kVA | S13-M-100/10/0.4 | 100kVA, 3-phase oil-immersed transformer, 50Hz, primary 10kV (HV 10kV), secondary 400V (LV 400V), S13, insulation A, impedance 4% | $1650copper-adjusted |
| 200 kVA | S13-M-200/10/0.4 | 200kVA, 3-phase oil-immersed transformer, 50Hz, primary 10kV (HV 10kV), secondary 400V (LV 400V), S13, insulation A, impedance 4.5% | $2750copper-adjusted |
| 315 kVA | S13-M-315/10/0.4 | 315kVA, 3-phase oil-immersed transformer, 50Hz, primary 10kV (HV 10kV), secondary 400V (LV 400V), S13, insulation A, impedance 4.5% | $3850copper-adjusted |
| 500 kVA | S13-M-500/10/0.4 | 500kVA, 3-phase oil-immersed transformer, 50Hz, primary 10kV (HV 10kV), secondary 400V (LV 400V), S13, insulation A, impedance 4.5% | $5400copper-adjusted |
| 630 kVA | S13-M-630/10/0.4 | 630kVA, 3-phase oil-immersed transformer, 50Hz, primary 10kV (HV 10kV), secondary 400V (LV 400V), S13, insulation A, impedance 4.5% | $6600copper-adjusted |
| 800 kVA | S13-M-800/10/0.4 | 800kVA, 3-phase oil-immersed transformer, 50Hz, primary 10kV (HV 10kV), secondary 400V (LV 400V), S13, insulation A, impedance 6% | $7700copper-adjusted |
| 1,000 kVA | S13-M-1000/10/0.4 | 1000kVA, 3-phase oil-immersed transformer, 50Hz, primary 10kV (HV 10kV), secondary 400V (LV 400V), S13, insulation A, impedance 6% | $9100copper-adjusted |
| 1,600 kVA | S13-M-1600/10/0.4 | 1600kVA, 3-phase oil-immersed transformer, 50Hz, primary 10kV (HV 10kV), secondary 400V (LV 400V), S13, insulation A, impedance 6% | $12900copper-adjusted |
| 2,000 kVA | S13-M-2000/10/0.4 | 2000kVA, 3-phase oil-immersed transformer, 50Hz, primary 10kV (HV 10kV), secondary 400V (LV 400V), S13, insulation A, impedance 6% | $15200copper-adjusted |
| 3,150 kVA | S13-M-3150/10/0.4 | 3150kVA, 3-phase oil-immersed transformer, 50Hz, primary 10kV (HV 10kV), secondary 400V (LV 400V), S13, insulation A, impedance 7% | $21300copper-adjusted |
| 5,000 kVA | S13-M-5000/10/0.4 | 5000kVA, 3-phase oil-immersed transformer, 50Hz, primary 10kV (HV 10kV), secondary 400V (LV 400V), S13, insulation A, impedance 7% | $30000copper-adjusted |
| 6,300 kVAcustom rating | S13-M-6300/10 | 6300kVA, 3-phase oil-immersed transformer (≥ 6300 kVA engineered to order) — primary 10–35 kV, secondary 0.4 kV, S13, copper winding. | Customquote on request |
Dry-Type Transformers — SCB13
Three-phase, SCB13 epoxy cast-resin, 10 kV / 0.4 kV, copper winding, Class F insulation, AN cooling, Dyn11, IEC 60076. Each model below links to its product detail page.
| Capacity | Model | Description | Reference price (FOB) |
|---|---|---|---|
| 100 kVA | SCB13-100/10/0.4 | 100kVA, 3-phase cast resin dry-type transformer, 50Hz, primary 10kV (HV 10kV), secondary 400V (LV 400V), SCB13, insulation F, impedance 4% | $2950copper-adjusted |
| 200 kVA | SCB13-200/10/0.4 | 200kVA, 3-phase cast resin dry-type transformer, 50Hz, primary 10kV (HV 10kV), secondary 400V (LV 400V), SCB13, insulation F, impedance 4.5% | $5000copper-adjusted |
| 315 kVA | SCB13-315/10/0.4 | 315kVA, 3-phase cast resin dry-type transformer, 50Hz, primary 10kV (HV 10kV), secondary 400V (LV 400V), SCB13, insulation F, impedance 4.5% | $7100copper-adjusted |
| 500 kVA | SCB13-500/10/0.4 | 500kVA, 3-phase cast resin dry-type transformer, 50Hz, primary 10kV (HV 10kV), secondary 400V (LV 400V), SCB13, insulation F, impedance 4.5% | $10000copper-adjusted |
| 630 kVA | SCB13-630/10/0.4 | 630kVA, 3-phase cast resin dry-type transformer, 50Hz, primary 10kV (HV 10kV), secondary 400V (LV 400V), SCB13, insulation F, impedance 4.5% | $10200copper-adjusted |
| 1,000 kVA | SCB13-1000/10/0.4 | 1000kVA, 3-phase cast resin dry-type transformer, 50Hz, primary 10kV (HV 10kV), secondary 400V (LV 400V), SCB13, insulation F, impedance 6% | $17100copper-adjusted |
| 1,600 kVA | SCB13-1600/10/0.4 | 1600kVA, 3-phase cast resin dry-type transformer, 50Hz, primary 10kV (HV 10kV), secondary 400V (LV 400V), SCB13, insulation F, impedance 6% | $24400copper-adjusted |
| 2,000 kVA | SCB13-2000/10/0.4 | 2000kVA, 3-phase cast resin dry-type transformer, 50Hz, primary 10kV (HV 10kV), secondary 400V (LV 400V), SCB13, insulation F, impedance 6% | $28900copper-adjusted |
Copper Price Link
Copper is the largest raw-material cost in a copper-wound transformer. All prices on this page are computed from the anchored LME copper price of $14,185/ton (2026-08-23). The live copper figures below are for reference and update automatically every day.
Adjustment formula
Applied to copper-wound models only — every reference price on this page is a copper-wound standard design.
Worked example — 1,000 kVA oil-immersed S13-M-1000/10/0.4
- Base table price (anchored to LME $14,185/ton, 2026-08-23): $9,100
- Copper factor at anchor: ×1.0000
- Reference price: ≈ $9,100 (FOB Qingdao, standard design, before other factor adjustments)
Price Factors
Every figure on this page assumes the same-house baseline (S13-M / SCB13, copper winding, 10 kV / 0.4 kV, Dyn11). These factors move the price up or down on request.
Copper vs. aluminium winding
Tables assume copper. Aluminium-wound units cost about ×0.65 but carry no copper linkage.
Loss class
Oil: S11 ×0.92, S13 ×1.0, S20 ×1.2, S22 ×1.38. Dry: SCB11 ×0.92, SCB13 ×1.0, SCB14 ×1.18, SCB15 ×1.3.
HV rating adjustment
From the 10 kV base: 6 kV ×0.96, 10–11 kV ×1.0, 13.8 kV ×1.05, 20 kV ×1.1, 22 kV ×1.12, 33 kV ×1.28, 35 kV ×1.3.
On-load vs off-load
Oil-immersed on-load tap changer adds ×1.22 over the off-load baseline.
Dry-type options
Insulation Class H ×1.1; enclosure IP20 ×1.06, IP23 ×1.1, IP31 ×1.14; forced-air (AF) cooling ×1.08.
Beyond FOB
FOB ends at Qingdao port. Sea freight, insurance, import duty and destination taxes are separate and quoted on request.
Pricing Basis & Disclaimer
- Basis: FOB Qingdao (China), standard design, copper winding, Dyn11, IEC 60076, factory reference price.
- Price band: the reference price carries a ±8% band against the base value to reflect configuration and component variance.
- Not included: sea freight, insurance, import duty, VAT, destination taxes or on-site installation.
- Copper index: prices are anchored to LME copper $14,185/ton (2026-08-23) and adjust ±3% per $1,000/ton.
- Validity: figures are market reference ranges, not a binding offer; final price comes from a written quotation against a confirmed specification.
- Custom: non-standard voltage, impedance, tapping, protection, enclosure or certification change both price and lead time.
Frequently Asked Questions
How much does a 1000 kVA transformer cost in China?
How does the copper price affect a transformer's price?
Why is a dry-type transformer more expensive than oil-immersed?
Are the model numbers on this page real products?
What does "FOB Qingdao" include and exclude?
How do I get a firm, binding quote?