SBH15-M Series - Oil-Immersed Amorphous Alloy Distribution Transformers
The SBH15-M series combines oil-immersion technology with amorphous alloy core material, achieving ultra-low no-load losses for energy-efficient power distribution.
Model Number Breakdown
Key Features
- Ultra-low no-load losses with amorphous alloy core
- Oil-immersion insulation for reliability
- Sealed construction for moisture protection
- Energy-efficient power distribution
Applications
- Energy-efficient grids
- Rural electrification
- Power distribution networks
- Sustainable infrastructure
TECHNICAL DRAWING
Model: SBH15-M-315/10.5 | Type: Amorphous alloy transformer | Capacity: 315 kVA
FRONT ELEVATION
ELECTRICAL SCHEMATIC
EFFICIENCY vs LOAD
SIDE VIEW
TOP VIEW
TERMINAL BLOCK
CORE & WINDING
LEGEND:
Specifications Range
All specifications and dimensions can be customized upon request
Model Selector
| Key parameters | Model Range |
|---|---|
| Capacity | 10–5000 kVA |
| HV Voltage (kV) | 6, 6.3, 6.6, 10, 10.5, 11… |
| LV Voltage (kV) | 0.4, 0.48, 0.22, 0.208 |
| Frequency (Hz) | 50, 60 |
| Impedance (%) | 4, 4.5, 5, 6, 7 |
| Cooling | ONAN |
| Efficiency | 4, Class 5 |
| Standard | GB1094, JB/T10318, IEC 60076, IEEE C57 / ANSI C84.1 |
| Connection | Dyn11, Dyn11 (IEC), Delta-Wye (IEEE Std) |
| Insulation class | A(105°C), A (105°C) |
| Allowed temperature rise | 65 |
| Noise level | ≤33 dB(A), ≤34 dB(A), ≤35 dB(A), ≤36 dB(A), ≤37 dB(A), ≤38 dB(A)… |
| Tap Changer | ±2×2.5% or ±5%, ±2×2.5% Multi-tap, ±5% Single-tap, ±5×2.5% Multi-tap |
| No-load loss | 15–834 W |
| Load loss | 390–38786 W |
| Compare | Model | Capacity (kVA) | HV Voltage (kV) | LV Voltage (kV) | Weight | Dimensions |
|---|---|---|---|---|---|---|
| SBH15-M-30/6 | 30kVA | 6 | 0.4 | 340 kg | 870×600×850 mm | |
| SBH15-M-30/6.3 | 30kVA | 6.3 | 0.4 | 340 kg | 870×600×850 mm | |
| SBH15-M-30/6.6 | 30kVA | 6.6 | 0.4 | 340 kg | 870×600×850 mm | |
| SBH15-M-30/10 | 30kVA | 10 | 0.4 | 340 kg | 870×600×850 mm | |
| SBH15-M-30/10.5 | 30kVA | 10.5 | 0.4 | 340 kg | 870×600×850 mm | |
| SBH15-M-30/11 | 30kVA | 11 | 0.4 | 340 kg | 870×600×850 mm | |
| SBH15-M-50/6 | 50kVA | 6 | 0.4 | 460 kg | 900×620×900 mm | |
| SBH15-M-50/6.3 | 50kVA | 6.3 | 0.4 | 460 kg | 900×620×900 mm | |
| SBH15-M-50/6.6 | 50kVA | 6.6 | 0.4 | 460 kg | 900×620×900 mm | |
| SBH15-M-50/10 | 50kVA | 10 | 0.4 | 460 kg | 900×620×900 mm | |
| SBH15-M-50/10.5 | 50kVA | 10.5 | 0.4 | 460 kg | 900×620×900 mm | |
| SBH15-M-50/11 | 50kVA | 11 | 0.4 | 460 kg | 900×620×900 mm | |
| SBH15-M-80/6 | 80kVA | 6 | 0.4 | 590 kg | 1000×680×1000 mm | |
| SBH15-M-80/6.3 | 80kVA | 6.3 | 0.4 | 590 kg | 1000×680×1000 mm | |
| SBH15-M-80/6.6 | 80kVA | 6.6 | 0.4 | 590 kg | 1000×680×1000 mm | |
| SBH15-M-80/10 | 80kVA | 10 | 0.4 | 590 kg | 1000×680×1000 mm | |
| SBH15-M-80/10.5 | 80kVA | 10.5 | 0.4 | 590 kg | 1000×680×1000 mm | |
| SBH15-M-80/11 | 80kVA | 11 | 0.4 | 590 kg | 1000×680×1000 mm | |
| SBH15-M-100/6 | 100kVA | 6 | 0.4 | 650 kg | 1050×700×1080 mm | |
| SBH15-M-100/6.3 | 100kVA | 6.3 | 0.4 | 650 kg | 1050×700×1080 mm | |
| SBH15-M-100/6.6 | 100kVA | 6.6 | 0.4 | 650 kg | 1050×700×1080 mm | |
| SBH15-M-100/10 | 100kVA | 10 | 0.4 | 650 kg | 1050×700×1080 mm | |
| SBH15-M-100/10.5 | 100kVA | 10.5 | 0.4 | 650 kg | 1050×700×1080 mm | |
| SBH15-M-100/11 | 100kVA | 11 | 0.4 | 650 kg | 1050×700×1080 mm | |
| SBH15-M-125/6 | 125kVA | 6 | 0.4 | 710 kg | 1075×810×1170 mm | |
| SBH15-M-125/6.3 | 125kVA | 6.3 | 0.4 | 710 kg | 1075×810×1170 mm | |
| SBH15-M-125/6.6 | 125kVA | 6.6 | 0.4 | 710 kg | 1075×810×1170 mm | |
| SBH15-M-125/10 | 125kVA | 10 | 0.4 | 710 kg | 1075×810×1170 mm | |
| SBH15-M-125/10.5 | 125kVA | 10.5 | 0.4 | 710 kg | 1075×810×1170 mm | |
| SBH15-M-125/11 | 125kVA | 11 | 0.4 | 710 kg | 1075×810×1170 mm | |
| SBH15-M-160/6 | 160kVA | 6 | 0.4 | 800 kg | 1110×970×1290 mm | |
| SBH15-M-160/6.3 | 160kVA | 6.3 | 0.4 | 800 kg | 1110×970×1290 mm | |
| SBH15-M-160/6.6 | 160kVA | 6.6 | 0.4 | 800 kg | 1110×970×1290 mm | |
| SBH15-M-160/10 | 160kVA | 10 | 0.4 | 800 kg | 1110×970×1290 mm | |
| SBH15-M-160/10.5 | 160kVA | 10.5 | 0.4 | 800 kg | 1110×970×1290 mm | |
| SBH15-M-160/11 | 160kVA | 11 | 0.4 | 800 kg | 1110×970×1290 mm | |
| SBH15-M-200/6 | 200kVA | 6 | 0.4 | 900 kg | 1150×990×1290 mm | |
| SBH15-M-200/6.3 | 200kVA | 6.3 | 0.4 | 900 kg | 1150×990×1290 mm | |
| SBH15-M-200/6.6 | 200kVA | 6.6 | 0.4 | 900 kg | 1150×990×1290 mm | |
| SBH15-M-200/10 | 200kVA | 10 | 0.4 | 900 kg | 1150×990×1290 mm | |
| SBH15-M-200/10.5 | 200kVA | 10.5 | 0.4 | 900 kg | 1150×990×1290 mm | |
| SBH15-M-200/11 | 200kVA | 11 | 0.4 | 900 kg | 1150×990×1290 mm | |
| SBH15-M-250/6 | 250kVA | 6 | 0.4 | 1020 kg | 1190×1030×1300 mm | |
| SBH15-M-250/6.3 | 250kVA | 6.3 | 0.4 | 1020 kg | 1190×1030×1300 mm | |
| SBH15-M-250/6.6 | 250kVA | 6.6 | 0.4 | 1020 kg | 1190×1030×1300 mm | |
| SBH15-M-250/10 | 250kVA | 10 | 0.4 | 1020 kg | 1190×1030×1300 mm | |
| SBH15-M-250/10.5 | 250kVA | 10.5 | 0.4 | 1020 kg | 1190×1030×1300 mm | |
| SBH15-M-250/11 | 250kVA | 11 | 0.4 | 1020 kg | 1190×1030×1300 mm | |
| SBH15-M-315/6 | 315kVA | 6 | 0.4 | 1200 kg | 1290×1120×1360 mm | |
| SBH15-M-315/6.3 | 315kVA | 6.3 | 0.4 | 1200 kg | 1290×1120×1360 mm | |
| SBH15-M-315/6.6 | 315kVA | 6.6 | 0.4 | 1200 kg | 1290×1120×1360 mm | |
| SBH15-M-315/10 | 315kVA | 10 | 0.4 | 1200 kg | 1290×1120×1360 mm | |
| SBH15-M-315/10.5 | 315kVA | 10.5 | 0.4 | 1200 kg | 1290×1120×1360 mm | |
| SBH15-M-315/11 | 315kVA | 11 | 0.4 | 1200 kg | 1290×1120×1360 mm | |
| SBH15-M-400/6 | 400kVA | 6 | 0.4 | 1350 kg | 1280×1110×1410 mm | |
| SBH15-M-400/6.3 | 400kVA | 6.3 | 0.4 | 1350 kg | 1280×1110×1410 mm | |
| SBH15-M-400/6.6 | 400kVA | 6.6 | 0.4 | 1350 kg | 1280×1110×1410 mm | |
| SBH15-M-400/10 | 400kVA | 10 | 0.4 | 1350 kg | 1280×1110×1410 mm | |
| SBH15-M-400/10.5 | 400kVA | 10.5 | 0.4 | 1350 kg | 1280×1110×1410 mm | |
| SBH15-M-400/11 | 400kVA | 11 | 0.4 | 1350 kg | 1280×1110×1410 mm | |
| SBH15-M-500/6 | 500kVA | 6 | 0.4 | 1550 kg | 1400×1210×1420 mm | |
| SBH15-M-500/6.3 | 500kVA | 6.3 | 0.4 | 1550 kg | 1400×1210×1420 mm | |
| SBH15-M-500/6.6 | 500kVA | 6.6 | 0.4 | 1550 kg | 1400×1210×1420 mm | |
| SBH15-M-500/10 | 500kVA | 10 | 0.4 | 1550 kg | 1400×1210×1420 mm | |
| SBH15-M-500/10.5 | 500kVA | 10.5 | 0.4 | 1550 kg | 1400×1210×1420 mm | |
| SBH15-M-500/11 | 500kVA | 11 | 0.4 | 1550 kg | 1400×1210×1420 mm | |
| SBH15-M-630/6 | 630kVA | 6 | 0.4 | 2200 kg | 1490×1170×1250 mm | |
| SBH15-M-630/6.3 | 630kVA | 6.3 | 0.4 | 2200 kg | 1490×1170×1250 mm | |
| SBH15-M-630/6.6 | 630kVA | 6.6 | 0.4 | 2200 kg | 1490×1170×1250 mm | |
| SBH15-M-630/10 | 630kVA | 10 | 0.4 | 2200 kg | 1490×1170×1250 mm | |
| SBH15-M-630/10.5 | 630kVA | 10.5 | 0.4 | 2200 kg | 1490×1170×1250 mm | |
| SBH15-M-630/11 | 630kVA | 11 | 0.4 | 2200 kg | 1490×1170×1250 mm | |
| SBH15-M-800/6 | 800kVA | 6 | 0.4 | 2550 kg | 1580×1300×1400 mm | |
| SBH15-M-800/6.3 | 800kVA | 6.3 | 0.4 | 2550 kg | 1580×1300×1400 mm | |
| SBH15-M-800/6.6 | 800kVA | 6.6 | 0.4 | 2550 kg | 1580×1300×1400 mm | |
| SBH15-M-800/10 | 800kVA | 10 | 0.4 | 2550 kg | 1580×1300×1400 mm | |
| SBH15-M-800/10.5 | 800kVA | 10.5 | 0.4 | 2550 kg | 1580×1300×1400 mm | |
| SBH15-M-800/11 | 800kVA | 11 | 0.4 | 2550 kg | 1580×1300×1400 mm | |
| SBH15-M-1000/6 | 1000kVA | 6 | 0.4 | 2800 kg | 1600×1400×1450 mm | |
| SBH15-M-1000/6.3 | 1000kVA | 6.3 | 0.4 | 2800 kg | 1600×1400×1450 mm | |
| SBH15-M-1000/6.6 | 1000kVA | 6.6 | 0.4 | 2800 kg | 1600×1400×1450 mm | |
| SBH15-M-1000/10 | 1000kVA | 10 | 0.4 | 2800 kg | 1600×1400×1450 mm | |
| SBH15-M-1000/10.5 | 1000kVA | 10.5 | 0.4 | 2800 kg | 1600×1400×1450 mm | |
| SBH15-M-1000/11 | 1000kVA | 11 | 0.4 | 2800 kg | 1600×1400×1450 mm | |
| SBH15-M-1250/6 | 1250kVA | 6 | 0.4 | 3200 kg | 1680×1510×1480 mm | |
| SBH15-M-1250/6.3 | 1250kVA | 6.3 | 0.4 | 3200 kg | 1680×1510×1480 mm | |
| SBH15-M-1250/6.6 | 1250kVA | 6.6 | 0.4 | 3200 kg | 1680×1510×1480 mm | |
| SBH15-M-1250/10 | 1250kVA | 10 | 0.4 | 3200 kg | 1680×1510×1480 mm | |
| SBH15-M-1250/10.5 | 1250kVA | 10.5 | 0.4 | 3200 kg | 1680×1510×1480 mm | |
| SBH15-M-1250/11 | 1250kVA | 11 | 0.4 | 3200 kg | 1680×1510×1480 mm | |
| SBH15-M-1600/6 | 1600kVA | 6 | 0.4 | 4030 kg | 1750×1550×1540 mm | |
| SBH15-M-1600/6.3 | 1600kVA | 6.3 | 0.4 | 4030 kg | 1750×1550×1540 mm | |
| SBH15-M-1600/6.6 | 1600kVA | 6.6 | 0.4 | 4030 kg | 1750×1550×1540 mm | |
| SBH15-M-1600/10 | 1600kVA | 10 | 0.4 | 4030 kg | 1750×1550×1540 mm | |
| SBH15-M-1600/10.5 | 1600kVA | 10.5 | 0.4 | 4030 kg | 1750×1550×1540 mm | |
| SBH15-M-1600/11 | 1600kVA | 11 | 0.4 | 4030 kg | 1750×1550×1540 mm | |
| SBH15-M-2000/6 | 2000kVA | 6 | 0.4 | 5550 kg | 1850×1600×1650 mm | |
| SBH15-M-2000/6.3 | 2000kVA | 6.3 | 0.4 | 5550 kg | 1850×1600×1650 mm | |
| SBH15-M-2000/6.6 | 2000kVA | 6.6 | 0.4 | 5550 kg | 1850×1600×1650 mm | |
| SBH15-M-2000/10 | 2000kVA | 10 | 0.4 | 5550 kg | 1850×1600×1650 mm | |
| SBH15-M-2000/10.5 | 2000kVA | 10.5 | 0.4 | 5550 kg | 1850×1600×1650 mm | |
| SBH15-M-2000/11 | 2000kVA | 11 | 0.4 | 5550 kg | 1850×1600×1650 mm | |
| SBH15-M-2500/6 | 2500kVA | 6 | 0.4 | 6500 kg | 1950×1700×1750 mm | |
| SBH15-M-2500/6.3 | 2500kVA | 6.3 | 0.4 | 6500 kg | 1950×1700×1750 mm | |
| SBH15-M-2500/6.6 | 2500kVA | 6.6 | 0.4 | 6500 kg | 1950×1700×1750 mm | |
| SBH15-M-2500/10 | 2500kVA | 10 | 0.4 | 6500 kg | 1950×1700×1750 mm | |
| SBH15-M-2500/10.5 | 2500kVA | 10.5 | 0.4 | 6500 kg | 1950×1700×1750 mm | |
| SBH15-M-2500/11 | 2500kVA | 11 | 0.4 | 6500 kg | 1950×1700×1750 mm | |
| SBH15-M-30/20 | 30kVA | 20 | 0.4 | 340 kg | 870×600×850 mm | |
| SBH15-M-30/22 | 30kVA | 22 | 0.4 | 340 kg | 870×600×850 mm | |
| SBH15-M-30/24 | 30kVA | 24 | 0.4 | 340 kg | 870×600×850 mm | |
| SBH15-M-50/20 | 50kVA | 20 | 0.4 | 460 kg | 900×620×900 mm | |
| SBH15-M-50/22 | 50kVA | 22 | 0.4 | 460 kg | 900×620×900 mm | |
| SBH15-M-50/24 | 50kVA | 24 | 0.4 | 460 kg | 900×620×900 mm | |
| SBH15-M-63/20 | 63kVA | 20 | 0.4 | 515 kg | 945×645×945 mm | |
| SBH15-M-63/22 | 63kVA | 22 | 0.4 | 515 kg | 945×645×945 mm | |
| SBH15-M-63/24 | 63kVA | 24 | 0.4 | 515 kg | 945×645×945 mm | |
| SBH15-M-80/20 | 80kVA | 20 | 0.4 | 590 kg | 1000×680×1000 mm | |
| SBH15-M-80/22 | 80kVA | 22 | 0.4 | 590 kg | 1000×680×1000 mm | |
| SBH15-M-80/24 | 80kVA | 24 | 0.4 | 590 kg | 1000×680×1000 mm | |
| SBH15-M-100/20 | 100kVA | 20 | 0.4 | 650 kg | 1050×700×1080 mm | |
| SBH15-M-100/22 | 100kVA | 22 | 0.4 | 650 kg | 1050×700×1080 mm | |
| SBH15-M-100/24 | 100kVA | 24 | 0.4 | 650 kg | 1050×700×1080 mm | |
| SBH15-M-125/20 | 125kVA | 20 | 0.4 | 710 kg | 1075×810×1170 mm | |
| SBH15-M-125/22 | 125kVA | 22 | 0.4 | 710 kg | 1075×810×1170 mm | |
| SBH15-M-125/24 | 125kVA | 24 | 0.4 | 710 kg | 1075×810×1170 mm | |
| SBH15-M-160/20 | 160kVA | 20 | 0.4 | 800 kg | 1110×970×1290 mm | |
| SBH15-M-160/22 | 160kVA | 22 | 0.4 | 800 kg | 1110×970×1290 mm | |
| SBH15-M-160/24 | 160kVA | 24 | 0.4 | 800 kg | 1110×970×1290 mm | |
| SBH15-M-200/20 | 200kVA | 20 | 0.4 | 900 kg | 1150×990×1290 mm | |
| SBH15-M-200/22 | 200kVA | 22 | 0.4 | 900 kg | 1150×990×1290 mm | |
| SBH15-M-200/24 | 200kVA | 24 | 0.4 | 900 kg | 1150×990×1290 mm | |
| SBH15-M-250/20 | 250kVA | 20 | 0.4 | 1020 kg | 1190×1030×1300 mm | |
| SBH15-M-250/22 | 250kVA | 22 | 0.4 | 1020 kg | 1190×1030×1300 mm | |
| SBH15-M-250/24 | 250kVA | 24 | 0.4 | 1020 kg | 1190×1030×1300 mm | |
| SBH15-M-315/20 | 315kVA | 20 | 0.4 | 1200 kg | 1290×1120×1360 mm | |
| SBH15-M-315/22 | 315kVA | 22 | 0.4 | 1200 kg | 1290×1120×1360 mm | |
| SBH15-M-315/24 | 315kVA | 24 | 0.4 | 1200 kg | 1290×1120×1360 mm | |
| SBH15-M-400/20 | 400kVA | 20 | 0.4 | 1350 kg | 1280×1110×1410 mm | |
| SBH15-M-400/22 | 400kVA | 22 | 0.4 | 1350 kg | 1280×1110×1410 mm | |
| SBH15-M-400/24 | 400kVA | 24 | 0.4 | 1350 kg | 1280×1110×1410 mm | |
| SBH15-M-500/20 | 500kVA | 20 | 0.4 | 1550 kg | 1400×1210×1420 mm | |
| SBH15-M-500/22 | 500kVA | 22 | 0.4 | 1550 kg | 1400×1210×1420 mm | |
| SBH15-M-500/24 | 500kVA | 24 | 0.4 | 1550 kg | 1400×1210×1420 mm | |
| SBH15-M-630/20 | 630kVA | 20 | 0.4 | 2200 kg | 1490×1170×1250 mm | |
| SBH15-M-630/22 | 630kVA | 22 | 0.4 | 2200 kg | 1490×1170×1250 mm | |
| SBH15-M-630/24 | 630kVA | 24 | 0.4 | 2200 kg | 1490×1170×1250 mm | |
| SBH15-M-800/20 | 800kVA | 20 | 0.4 | 2550 kg | 1580×1300×1400 mm | |
| SBH15-M-800/22 | 800kVA | 22 | 0.4 | 2550 kg | 1580×1300×1400 mm | |
| SBH15-M-800/24 | 800kVA | 24 | 0.4 | 2550 kg | 1580×1300×1400 mm | |
| SBH15-M-1000/20 | 1000kVA | 20 | 0.4 | 2800 kg | 1600×1400×1450 mm | |
| SBH15-M-1000/22 | 1000kVA | 22 | 0.4 | 2800 kg | 1600×1400×1450 mm | |
| SBH15-M-1000/24 | 1000kVA | 24 | 0.4 | 2800 kg | 1600×1400×1450 mm | |
| SBH15-M-1250/20 | 1250kVA | 20 | 0.4 | 3200 kg | 1680×1510×1480 mm | |
| SBH15-M-1250/22 | 1250kVA | 22 | 0.4 | 3200 kg | 1680×1510×1480 mm | |
| SBH15-M-1250/24 | 1250kVA | 24 | 0.4 | 3200 kg | 1680×1510×1480 mm | |
| SBH15-M-1600/20 | 1600kVA | 20 | 0.4 | 4030 kg | 1750×1550×1540 mm | |
| SBH15-M-1600/22 | 1600kVA | 22 | 0.4 | 4030 kg | 1750×1550×1540 mm | |
| SBH15-M-1600/24 | 1600kVA | 24 | 0.4 | 4030 kg | 1750×1550×1540 mm | |
| SBH15-M-2000/20 | 2000kVA | 20 | 0.4 | 5550 kg | 1850×1600×1650 mm | |
| SBH15-M-2000/22 | 2000kVA | 22 | 0.4 | 5550 kg | 1850×1600×1650 mm | |
| SBH15-M-2000/24 | 2000kVA | 24 | 0.4 | 5550 kg | 1850×1600×1650 mm | |
| SBH15-M-2500/20 | 2500kVA | 20 | 0.4 | 6500 kg | 1950×1700×1750 mm | |
| SBH15-M-2500/22 | 2500kVA | 22 | 0.4 | 6500 kg | 1950×1700×1750 mm | |
| SBH15-M-2500/24 | 2500kVA | 24 | 0.4 | 6500 kg | 1950×1700×1750 mm | |
| SBH15-M-10/10/0.4 | 10kVA | 10 | 0.4 | 240 kg | 650×450×750 mm | |
| SBH15-M-10/6/0.4 | 10kVA | 6 | 0.4 | 240 kg | 650×450×750 mm | |
| SBH15-M-10/35/0.4 | 10kVA | 35 | 0.4 | 240 kg | 650×450×750 mm | |
| SBH15-M-10/10/0.48 | 10kVA | 10 | 0.48 | 240 kg | 650×450×750 mm | |
| SBH15-M-10/10/0.22 | 10kVA | 10 | 0.22 | 240 kg | 650×450×750 mm | |
| SBH15-M-10/0.48/0.208 | 10kVA | 0.48 | 0.208 | 240 kg | 650×450×750 mm | |
| SBH15-M-15/10/0.4 | 15kVA | 10 | 0.4 | 260 kg | 675×475×775 mm | |
| SBH15-M-15/6/0.4 | 15kVA | 6 | 0.4 | 260 kg | 675×475×775 mm | |
| SBH15-M-15/35/0.4 | 15kVA | 35 | 0.4 | 260 kg | 675×475×775 mm | |
| SBH15-M-15/10/0.48 | 15kVA | 10 | 0.48 | 260 kg | 675×475×775 mm | |
| SBH15-M-15/10/0.22 | 15kVA | 10 | 0.22 | 260 kg | 675×475×775 mm | |
| SBH15-M-15/0.48/0.208 | 15kVA | 0.48 | 0.208 | 260 kg | 675×475×775 mm | |
| SBH15-M-20/10/0.4 | 20kVA | 10 | 0.4 | 280 kg | 700×500×800 mm | |
| SBH15-M-20/6/0.4 | 20kVA | 6 | 0.4 | 280 kg | 700×500×800 mm | |
| SBH15-M-20/35/0.4 | 20kVA | 35 | 0.4 | 280 kg | 700×500×800 mm | |
| SBH15-M-20/10/0.48 | 20kVA | 10 | 0.48 | 280 kg | 700×500×800 mm | |
| SBH15-M-20/10/0.22 | 20kVA | 10 | 0.22 | 280 kg | 700×500×800 mm | |
| SBH15-M-20/0.48/0.208 | 20kVA | 0.48 | 0.208 | 280 kg | 700×500×800 mm | |
| SBH15-M-25/10/0.4 | 25kVA | 10 | 0.4 | 310 kg | 785×550×825 mm | |
| SBH15-M-25/6/0.4 | 25kVA | 6 | 0.4 | 310 kg | 785×550×825 mm | |
| SBH15-M-25/35/0.4 | 25kVA | 35 | 0.4 | 310 kg | 785×550×825 mm | |
| SBH15-M-25/10/0.48 | 25kVA | 10 | 0.48 | 310 kg | 785×550×825 mm | |
| SBH15-M-25/10/0.22 | 25kVA | 10 | 0.22 | 310 kg | 785×550×825 mm | |
| SBH15-M-25/0.48/0.208 | 25kVA | 0.48 | 0.208 | 310 kg | 785×550×825 mm | |
| SBH15-M-30/10/0.4 | 30kVA | 10 | 0.4 | 340 kg | 870×600×850 mm | |
| SBH15-M-30/6/0.4 | 30kVA | 6 | 0.4 | 340 kg | 870×600×850 mm | |
| SBH15-M-30/35/0.4 | 30kVA | 35 | 0.4 | 340 kg | 870×600×850 mm | |
| SBH15-M-30/10/0.48 | 30kVA | 10 | 0.48 | 340 kg | 870×600×850 mm | |
| SBH15-M-30/10/0.22 | 30kVA | 10 | 0.22 | 340 kg | 870×600×850 mm | |
| SBH15-M-30/0.48/0.208 | 30kVA | 0.48 | 0.208 | 340 kg | 870×600×850 mm | |
| SBH15-M-40/10/0.4 | 40kVA | 10 | 0.4 | 400 kg | 885×610×875 mm | |
| SBH15-M-40/6/0.4 | 40kVA | 6 | 0.4 | 400 kg | 885×610×875 mm | |
| SBH15-M-40/35/0.4 | 40kVA | 35 | 0.4 | 400 kg | 885×610×875 mm | |
| SBH15-M-40/10/0.48 | 40kVA | 10 | 0.48 | 400 kg | 885×610×875 mm | |
| SBH15-M-40/10/0.22 | 40kVA | 10 | 0.22 | 400 kg | 885×610×875 mm | |
| SBH15-M-40/0.48/0.208 | 40kVA | 0.48 | 0.208 | 400 kg | 885×610×875 mm | |
| SBH15-M-50/10/0.4 | 50kVA | 10 | 0.4 | 460 kg | 900×620×900 mm | |
| SBH15-M-50/6/0.4 | 50kVA | 6 | 0.4 | 460 kg | 900×620×900 mm | |
| SBH15-M-50/35/0.4 | 50kVA | 35 | 0.4 | 460 kg | 900×620×900 mm | |
| SBH15-M-50/10/0.48 | 50kVA | 10 | 0.48 | 460 kg | 900×620×900 mm | |
| SBH15-M-50/10/0.22 | 50kVA | 10 | 0.22 | 460 kg | 900×620×900 mm | |
| SBH15-M-50/0.48/0.208 | 50kVA | 0.48 | 0.208 | 460 kg | 900×620×900 mm | |
| SBH15-M-63/10/0.4 | 63kVA | 10 | 0.4 | 515 kg | 945×645×945 mm | |
| SBH15-M-63/6/0.4 | 63kVA | 6 | 0.4 | 515 kg | 945×645×945 mm | |
| SBH15-M-63/35/0.4 | 63kVA | 35 | 0.4 | 515 kg | 945×645×945 mm | |
| SBH15-M-63/10/0.48 | 63kVA | 10 | 0.48 | 515 kg | 945×645×945 mm | |
| SBH15-M-63/10/0.22 | 63kVA | 10 | 0.22 | 515 kg | 945×645×945 mm | |
| SBH15-M-63/0.48/0.208 | 63kVA | 0.48 | 0.208 | 515 kg | 945×645×945 mm | |
| SBH15-M-80/10/0.4 | 80kVA | 10 | 0.4 | 590 kg | 1000×680×1000 mm | |
| SBH15-M-80/6/0.4 | 80kVA | 6 | 0.4 | 590 kg | 1000×680×1000 mm | |
| SBH15-M-80/35/0.4 | 80kVA | 35 | 0.4 | 590 kg | 1000×680×1000 mm | |
| SBH15-M-80/10/0.48 | 80kVA | 10 | 0.48 | 590 kg | 1000×680×1000 mm | |
| SBH15-M-80/10/0.22 | 80kVA | 10 | 0.22 | 590 kg | 1000×680×1000 mm | |
| SBH15-M-80/0.48/0.208 | 80kVA | 0.48 | 0.208 | 590 kg | 1000×680×1000 mm | |
| SBH15-M-100/10/0.4 | 100kVA | 10 | 0.4 | 650 kg | 1050×700×1080 mm | |
| SBH15-M-100/6/0.4 | 100kVA | 6 | 0.4 | 650 kg | 1050×700×1080 mm | |
| SBH15-M-100/35/0.4 | 100kVA | 35 | 0.4 | 650 kg | 1050×700×1080 mm | |
| SBH15-M-100/10/0.48 | 100kVA | 10 | 0.48 | 650 kg | 1050×700×1080 mm | |
| SBH15-M-100/10/0.22 | 100kVA | 10 | 0.22 | 650 kg | 1050×700×1080 mm | |
| SBH15-M-100/0.48/0.208 | 100kVA | 0.48 | 0.208 | 650 kg | 1050×700×1080 mm | |
| SBH15-M-125/10/0.4 | 125kVA | 10 | 0.4 | 710 kg | 1075×810×1170 mm | |
| SBH15-M-125/6/0.4 | 125kVA | 6 | 0.4 | 710 kg | 1075×810×1170 mm | |
| SBH15-M-125/35/0.4 | 125kVA | 35 | 0.4 | 710 kg | 1075×810×1170 mm | |
| SBH15-M-125/10/0.48 | 125kVA | 10 | 0.48 | 710 kg | 1075×810×1170 mm | |
| SBH15-M-125/10/0.22 | 125kVA | 10 | 0.22 | 710 kg | 1075×810×1170 mm | |
| SBH15-M-125/0.48/0.208 | 125kVA | 0.48 | 0.208 | 710 kg | 1075×810×1170 mm | |
| SBH15-M-160/10/0.4 | 160kVA | 10 | 0.4 | 800 kg | 1110×970×1290 mm | |
| SBH15-M-160/6/0.4 | 160kVA | 6 | 0.4 | 800 kg | 1110×970×1290 mm | |
| SBH15-M-160/35/0.4 | 160kVA | 35 | 0.4 | 800 kg | 1110×970×1290 mm | |
| SBH15-M-160/10/0.48 | 160kVA | 10 | 0.48 | 800 kg | 1110×970×1290 mm | |
| SBH15-M-160/10/0.22 | 160kVA | 10 | 0.22 | 800 kg | 1110×970×1290 mm | |
| SBH15-M-160/0.48/0.208 | 160kVA | 0.48 | 0.208 | 800 kg | 1110×970×1290 mm | |
| SBH15-M-200/10/0.4 | 200kVA | 10 | 0.4 | 900 kg | 1150×990×1290 mm | |
| SBH15-M-200/6/0.4 | 200kVA | 6 | 0.4 | 900 kg | 1150×990×1290 mm | |
| SBH15-M-200/35/0.4 | 200kVA | 35 | 0.4 | 900 kg | 1150×990×1290 mm | |
| SBH15-M-200/10/0.48 | 200kVA | 10 | 0.48 | 900 kg | 1150×990×1290 mm | |
| SBH15-M-200/10/0.22 | 200kVA | 10 | 0.22 | 900 kg | 1150×990×1290 mm | |
| SBH15-M-200/0.48/0.208 | 200kVA | 0.48 | 0.208 | 900 kg | 1150×990×1290 mm | |
| SBH15-M-250/10/0.4 | 250kVA | 10 | 0.4 | 1020 kg | 1190×1030×1300 mm | |
| SBH15-M-250/6/0.4 | 250kVA | 6 | 0.4 | 1020 kg | 1190×1030×1300 mm | |
| SBH15-M-250/35/0.4 | 250kVA | 35 | 0.4 | 1020 kg | 1190×1030×1300 mm | |
| SBH15-M-250/10/0.48 | 250kVA | 10 | 0.48 | 1020 kg | 1190×1030×1300 mm | |
| SBH15-M-250/10/0.22 | 250kVA | 10 | 0.22 | 1020 kg | 1190×1030×1300 mm | |
| SBH15-M-250/0.48/0.208 | 250kVA | 0.48 | 0.208 | 1020 kg | 1190×1030×1300 mm | |
| SBH15-M-315/10/0.4 | 315kVA | 10 | 0.4 | 1200 kg | 1290×1120×1360 mm | |
| SBH15-M-315/6/0.4 | 315kVA | 6 | 0.4 | 1200 kg | 1290×1120×1360 mm | |
| SBH15-M-315/35/0.4 | 315kVA | 35 | 0.4 | 1200 kg | 1290×1120×1360 mm | |
| SBH15-M-315/10/0.48 | 315kVA | 10 | 0.48 | 1200 kg | 1290×1120×1360 mm | |
| SBH15-M-315/10/0.22 | 315kVA | 10 | 0.22 | 1200 kg | 1290×1120×1360 mm | |
| SBH15-M-315/0.48/0.208 | 315kVA | 0.48 | 0.208 | 1200 kg | 1290×1120×1360 mm | |
| SBH15-M-400/10/0.4 | 400kVA | 10 | 0.4 | 1350 kg | 1280×1110×1410 mm | |
| SBH15-M-400/6/0.4 | 400kVA | 6 | 0.4 | 1350 kg | 1280×1110×1410 mm | |
| SBH15-M-400/35/0.4 | 400kVA | 35 | 0.4 | 1350 kg | 1280×1110×1410 mm | |
| SBH15-M-400/10/0.48 | 400kVA | 10 | 0.48 | 1350 kg | 1280×1110×1410 mm | |
| SBH15-M-400/10/0.22 | 400kVA | 10 | 0.22 | 1350 kg | 1280×1110×1410 mm | |
| SBH15-M-400/0.48/0.208 | 400kVA | 0.48 | 0.208 | 1350 kg | 1280×1110×1410 mm | |
| SBH15-M-500/10/0.4 | 500kVA | 10 | 0.4 | 1550 kg | 1400×1210×1420 mm | |
| SBH15-M-500/6/0.4 | 500kVA | 6 | 0.4 | 1550 kg | 1400×1210×1420 mm | |
| SBH15-M-500/35/0.4 | 500kVA | 35 | 0.4 | 1550 kg | 1400×1210×1420 mm | |
| SBH15-M-500/10/0.48 | 500kVA | 10 | 0.48 | 1550 kg | 1400×1210×1420 mm | |
| SBH15-M-500/10/0.22 | 500kVA | 10 | 0.22 | 1550 kg | 1400×1210×1420 mm | |
| SBH15-M-500/0.48/0.208 | 500kVA | 0.48 | 0.208 | 1550 kg | 1400×1210×1420 mm | |
| SBH15-M-630/10/0.4 | 630kVA | 10 | 0.4 | 2200 kg | 1490×1170×1250 mm | |
| SBH15-M-630/6/0.4 | 630kVA | 6 | 0.4 | 2200 kg | 1490×1170×1250 mm | |
| SBH15-M-630/35/0.4 | 630kVA | 35 | 0.4 | 2200 kg | 1490×1170×1250 mm | |
| SBH15-M-630/10/0.48 | 630kVA | 10 | 0.48 | 2200 kg | 1490×1170×1250 mm | |
| SBH15-M-630/10/0.22 | 630kVA | 10 | 0.22 | 2200 kg | 1490×1170×1250 mm | |
| SBH15-M-630/0.48/0.208 | 630kVA | 0.48 | 0.208 | 2200 kg | 1490×1170×1250 mm | |
| SBH15-M-800/10/0.4 | 800kVA | 10 | 0.4 | 2550 kg | 1580×1300×1400 mm | |
| SBH15-M-800/6/0.4 | 800kVA | 6 | 0.4 | 2550 kg | 1580×1300×1400 mm | |
| SBH15-M-800/35/0.4 | 800kVA | 35 | 0.4 | 2550 kg | 1580×1300×1400 mm | |
| SBH15-M-800/10/0.48 | 800kVA | 10 | 0.48 | 2550 kg | 1580×1300×1400 mm | |
| SBH15-M-800/10/0.22 | 800kVA | 10 | 0.22 | 2550 kg | 1580×1300×1400 mm | |
| SBH15-M-800/0.48/0.208 | 800kVA | 0.48 | 0.208 | 2550 kg | 1580×1300×1400 mm | |
| SBH15-M-1000/10/0.4 | 1000kVA | 10 | 0.4 | 2800 kg | 1600×1400×1450 mm | |
| SBH15-M-1000/6/0.4 | 1000kVA | 6 | 0.4 | 2800 kg | 1600×1400×1450 mm | |
| SBH15-M-1000/35/0.4 | 1000kVA | 35 | 0.4 | 2800 kg | 1600×1400×1450 mm | |
| SBH15-M-1000/10/0.48 | 1000kVA | 10 | 0.48 | 2800 kg | 1600×1400×1450 mm | |
| SBH15-M-1000/10/0.22 | 1000kVA | 10 | 0.22 | 2800 kg | 1600×1400×1450 mm | |
| SBH15-M-1000/0.48/0.208 | 1000kVA | 0.48 | 0.208 | 2800 kg | 1600×1400×1450 mm | |
| SBH15-M-1250/10/0.4 | 1250kVA | 10 | 0.4 | 3200 kg | 1680×1510×1480 mm | |
| SBH15-M-1250/6/0.4 | 1250kVA | 6 | 0.4 | 3200 kg | 1680×1510×1480 mm | |
| SBH15-M-1250/35/0.4 | 1250kVA | 35 | 0.4 | 3200 kg | 1680×1510×1480 mm | |
| SBH15-M-1250/10/0.48 | 1250kVA | 10 | 0.48 | 3200 kg | 1680×1510×1480 mm | |
| SBH15-M-1250/10/0.22 | 1250kVA | 10 | 0.22 | 3200 kg | 1680×1510×1480 mm | |
| SBH15-M-1250/0.48/0.208 | 1250kVA | 0.48 | 0.208 | 3200 kg | 1680×1510×1480 mm | |
| SBH15-M-1600/10/0.4 | 1600kVA | 10 | 0.4 | 4030 kg | 1750×1550×1540 mm | |
| SBH15-M-1600/6/0.4 | 1600kVA | 6 | 0.4 | 4030 kg | 1750×1550×1540 mm | |
| SBH15-M-1600/35/0.4 | 1600kVA | 35 | 0.4 | 4030 kg | 1750×1550×1540 mm | |
| SBH15-M-1600/10/0.48 | 1600kVA | 10 | 0.48 | 4030 kg | 1750×1550×1540 mm | |
| SBH15-M-1600/10/0.22 | 1600kVA | 10 | 0.22 | 4030 kg | 1750×1550×1540 mm | |
| SBH15-M-1600/0.48/0.208 | 1600kVA | 0.48 | 0.208 | 4030 kg | 1750×1550×1540 mm | |
| SBH15-M-2000/10/0.4 | 2000kVA | 10 | 0.4 | 5550 kg | 1850×1600×1650 mm | |
| SBH15-M-2000/6/0.4 | 2000kVA | 6 | 0.4 | 5550 kg | 1850×1600×1650 mm | |
| SBH15-M-2000/35/0.4 | 2000kVA | 35 | 0.4 | 5550 kg | 1850×1600×1650 mm | |
| SBH15-M-2000/10/0.48 | 2000kVA | 10 | 0.48 | 5550 kg | 1850×1600×1650 mm | |
| SBH15-M-2000/10/0.22 | 2000kVA | 10 | 0.22 | 5550 kg | 1850×1600×1650 mm | |
| SBH15-M-2000/0.48/0.208 | 2000kVA | 0.48 | 0.208 | 5550 kg | 1850×1600×1650 mm | |
| SBH15-M-2500/10/0.4 | 2500kVA | 10 | 0.4 | 6500 kg | 1950×1700×1750 mm | |
| SBH15-M-2500/6/0.4 | 2500kVA | 6 | 0.4 | 6500 kg | 1950×1700×1750 mm | |
| SBH15-M-2500/35/0.4 | 2500kVA | 35 | 0.4 | 6500 kg | 1950×1700×1750 mm | |
| SBH15-M-2500/10/0.48 | 2500kVA | 10 | 0.48 | 6500 kg | 1950×1700×1750 mm | |
| SBH15-M-2500/10/0.22 | 2500kVA | 10 | 0.22 | 6500 kg | 1950×1700×1750 mm | |
| SBH15-M-2500/0.48/0.208 | 2500kVA | 0.48 | 0.208 | 6500 kg | 1950×1700×1750 mm | |
| SBH15-M-3150/10/0.4 | 3150kVA | 10 | 0.4 | 7800 kg | 2100×1800×1900 mm | |
| SBH15-M-3150/6/0.4 | 3150kVA | 6 | 0.4 | 7800 kg | 2100×1800×1900 mm | |
| SBH15-M-3150/35/0.4 | 3150kVA | 35 | 0.4 | 7800 kg | 2100×1800×1900 mm | |
| SBH15-M-3150/10/0.48 | 3150kVA | 10 | 0.48 | 7800 kg | 2100×1800×1900 mm | |
| SBH15-M-3150/10/0.22 | 3150kVA | 10 | 0.22 | 7800 kg | 2100×1800×1900 mm | |
| SBH15-M-3150/0.48/0.208 | 3150kVA | 0.48 | 0.208 | 7800 kg | 2100×1800×1900 mm | |
| SBH15-M-4000/10/0.4 | 4000kVA | 10 | 0.4 | 7800 kg | 2100×1800×1900 mm | |
| SBH15-M-4000/6/0.4 | 4000kVA | 6 | 0.4 | 7800 kg | 2100×1800×1900 mm | |
| SBH15-M-4000/35/0.4 | 4000kVA | 35 | 0.4 | 7800 kg | 2100×1800×1900 mm | |
| SBH15-M-4000/10/0.48 | 4000kVA | 10 | 0.48 | 7800 kg | 2100×1800×1900 mm | |
| SBH15-M-4000/10/0.22 | 4000kVA | 10 | 0.22 | 7800 kg | 2100×1800×1900 mm | |
| SBH15-M-4000/0.48/0.208 | 4000kVA | 0.48 | 0.208 | 7800 kg | 2100×1800×1900 mm | |
| SBH15-M-5000/10/0.4 | 5000kVA | 10 | 0.4 | 7800 kg | 2100×1800×1900 mm | |
| SBH15-M-5000/6/0.4 | 5000kVA | 6 | 0.4 | 7800 kg | 2100×1800×1900 mm | |
| SBH15-M-5000/35/0.4 | 5000kVA | 35 | 0.4 | 7800 kg | 2100×1800×1900 mm | |
| SBH15-M-5000/10/0.48 | 5000kVA | 10 | 0.48 | 7800 kg | 2100×1800×1900 mm | |
| SBH15-M-5000/10/0.22 | 5000kVA | 10 | 0.22 | 7800 kg | 2100×1800×1900 mm | |
| SBH15-M-5000/0.48/0.208 | 5000kVA | 0.48 | 0.208 | 7800 kg | 2100×1800×1900 mm |
Selection Guide
Load profile
Amorphous cores cut no-load loss 60-70% - best where load is light or idle time is long (rural, solar).
Noise
Slightly higher noise than silicon steel - confirm the site noise requirement.
Capacity & voltage
Standard distribution sizing with your supply voltage.
- Frequently Asked Questions
What is an amorphous core?
A metal-glass alloy core that reduces no-load losses by 60-70% versus silicon steel.
How much energy does SBH15-M save?
No-load losses drop significantly, ideal for lightly loaded or long-idle transformers like rural and solar applications.
Is amorphous louder?
Slightly, but modern clamping keeps noise comparable to silicon-steel units.
Instant Selection & Quote Calculator
Select your specifications to get an estimated price instantly.
More options(2)
Certification
The values below are computed from what you selected above. Anything that cannot be computed yet is shown as an em dash — never as zero.
Iₙ = S / (√3·U) · I_sc = 100·Iₙ / uₖ · S_sc = √3·U·I_sc · I_p = k·Iₖ
Still required to complete the calculation: rated capacity S, impedance voltage uₖ, short-time or peak withstand current.
Per-model values (P0 / Pk / uₖ declared by the factory, losses, noise, temperature rise, dimensions, weight) are not in the product library: those rows stay at an em dash until the factory parameter sheet is supplied. An em dash means the value is unavailable — it is never rendered as zero.
Read-only: no price factor, not part of the sum — the loss-grade cost is already carried by the efficiency (subtype) base price, so charging here would double-bill. Values come from the product library type-test data, interpolated between published capacities; grades the library does not cover show an em dash, never zero.
油浸非晶(SBH15-M / SH16)
Reference prices are for estimation only and do not constitute a formal offer.
3 · Get this quote
We will reply with your latest quote instantly.
Related Engineering Calculators
Free sizing and pricing tools for this product category.